BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 21062921)

  • 1. Nonlinear three-dimensional noise filter with low-dose CT angiography: effect on the detection of small high-contrast objects in a phantom model.
    Szucs-Farkas Z; Bensler S; Torrente JC; Cullmann JL; Vock P; Schindera ST
    Radiology; 2011 Jan; 258(1):261-9. PubMed ID: 21062921
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Endoleak and in-stent thrombus detection with CT angiography in a thoracic aortic aneurysm phantom at different tube energies using filtered back projection and iterative algorithms.
    Deák Z; Grimm JM; Mueck F; Geyer LL; Treitl M; Reiser MF; Wirth S
    Radiology; 2014 May; 271(2):574-84. PubMed ID: 24475853
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Endoleak detection with CT angiography in an abdominal aortic aneurysm phantom: effect of tube energy, simulated patient size, and physical properties of endoleaks.
    Szucs-Farkas Z; Semadeni M; Bensler S; Patak MA; von Allmen G; Vock P; Schindera ST
    Radiology; 2009 May; 251(2):590-8. PubMed ID: 19401582
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: a phantom study.
    Schindera ST; Winklehner A; Alkadhi H; Goetti R; Fischer M; Gnannt R; Szucs-Farkas Z
    Clin Radiol; 2013 Feb; 68(2):e79-86. PubMed ID: 23219454
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study.
    Schindera ST; Diedrichsen L; Müller HC; Rusch O; Marin D; Schmidt B; Raupach R; Vock P; Szucs-Farkas Z
    Radiology; 2011 Aug; 260(2):454-62. PubMed ID: 21493795
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study.
    Schindera ST; Nelson RC; Yoshizumi T; Toncheva G; Nguyen G; DeLong DM; Szucs-Farkas Z
    Acad Radiol; 2009 Aug; 16(8):997-1002. PubMed ID: 19409820
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dual-Energy Low-keV or Single-Energy Low-kV CT for Endoleak Detection?: A 6-Reader Study in an Aortic Aneurysm Phantom.
    Skawran S; Angst F; Blüthgen C; Eberhard M; Kälin P; Kobe A; Nagy D; Szucs-Farkas Z; Alkadhi H; Euler A
    Invest Radiol; 2020 Jan; 55(1):45-52. PubMed ID: 31503078
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Circle of Willis at CT angiography: dose reduction and image quality--reducing tube voltage and increasing tube current settings.
    Waaijer A; Prokop M; Velthuis BK; Bakker CJ; de Kort GA; van Leeuwen MS
    Radiology; 2007 Mar; 242(3):832-9. PubMed ID: 17229873
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.
    Marin D; Nelson RC; Schindera ST; Richard S; Youngblood RS; Yoshizumi TT; Samei E
    Radiology; 2010 Jan; 254(1):145-53. PubMed ID: 20032149
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of X-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study.
    Szucs-Farkas Z; Verdun FR; von Allmen G; Mini RL; Vock P
    Invest Radiol; 2008 Jun; 43(6):374-81. PubMed ID: 18496042
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of beam hardening on arterial enhancement in thoracoabdominal CT angiography with increasing patient size: an in vitro and in vivo study.
    Schindera ST; Tock I; Marin D; Nelson RC; Raupach R; Hagemeister M; von Allmen G; Vock P; Szucs-Farkas Z
    Radiology; 2010 Aug; 256(2):528-35. PubMed ID: 20656839
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Time-resolved CT angiography for the detection and classification of endoleaks.
    Sommer WH; Becker CR; Haack M; Rubin GD; Weidenhagen R; Schwarz F; Nikolaou K; Reiser MF; Johnson TR; Clevert DA
    Radiology; 2012 Jun; 263(3):917-26. PubMed ID: 22623699
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low-dose MDCT urography: feasibility study of low-tube-voltage technique and adaptive noise reduction filter.
    Yanaga Y; Awai K; Funama Y; Nakaura T; Hirai T; Roux S; Yamashita Y
    AJR Am J Roentgenol; 2009 Sep; 193(3):W220-9. PubMed ID: 19696263
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter: evaluation with a computer-simulated liver including tumors.
    Funama Y; Awai K; Miyazaki O; Nakayama Y; Goto T; Omi Y; Shimonobo T; Liu D; Yamashita Y; Hori S
    Invest Radiol; 2006 Jan; 41(1):1-7. PubMed ID: 16355033
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: a comparative analysis of image quality and radiation exposure.
    Stiller W; Schwarzwaelder CB; Sommer CM; Veloza S; Radeleff BA; Kauczor HU
    Eur J Radiol; 2012 Jul; 81(7):1405-12. PubMed ID: 21458939
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optimal multidetector row CT parameters for evaluations of the breast: a phantom and specimen study.
    Yi A; Seo BK; Cho PK; Pisano ED; Lee KY; Je BK; Kim HY; Min BW; Son GS
    Acad Radiol; 2010 Jun; 17(6):744-51. PubMed ID: 20457417
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: phantom and preliminary studies.
    Kim KS; Lee JM; Kim SH; Kim KW; Kim SJ; Cho SH; Han JK; Choi BI
    Invest Radiol; 2010 Mar; 45(3):149-57. PubMed ID: 20142749
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study.
    Heyer CM; Mohr PS; Lemburg SP; Peters SA; Nicolas V
    Radiology; 2007 Nov; 245(2):577-83. PubMed ID: 17940308
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Abdominal CT: an intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination.
    Yamada Y; Jinzaki M; Hosokawa T; Tanami Y; Abe T; Kuribayashi S
    Eur J Radiol; 2014 Oct; 83(10):1715-22. PubMed ID: 25015416
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners.
    Ay MR; Mehranian A; Maleki A; Ghadiri H; Ghafarian P; Zaidi H
    Phys Med; 2013 May; 29(3):249-60. PubMed ID: 22541061
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.