866 related articles for article (PubMed ID: 21064263)
1. Assessment of the storz video Macintosh laryngoscope for use in difficult airways: A human simulator study.
Bair AE; Olmsted K; Brown CA; Barker T; Pallin D; Walls RM
Acad Emerg Med; 2010 Oct; 17(10):1134-7. PubMed ID: 21064263
[TBL] [Abstract][Full Text] [Related]
2. Prospective model-based comparison of different laryngoscopes for difficult intubation in infants.
Kalbhenn J; Boelke AK; Steinmann D
Paediatr Anaesth; 2012 Aug; 22(8):776-80. PubMed ID: 22646973
[TBL] [Abstract][Full Text] [Related]
3. Improved glottic exposure with the Video Macintosh Laryngoscope in adult emergency department tracheal intubations.
Brown CA; Bair AE; Pallin DJ; Laurin EG; Walls RM;
Ann Emerg Med; 2010 Aug; 56(2):83-8. PubMed ID: 20202720
[TBL] [Abstract][Full Text] [Related]
4. Comparison of intubation success of video laryngoscopy versus direct laryngoscopy in the difficult airway using high-fidelity simulation.
Narang AT; Oldeg PF; Medzon R; Mahmood AR; Spector JA; Robinett DA
Simul Healthc; 2009; 4(3):160-5. PubMed ID: 19680083
[TBL] [Abstract][Full Text] [Related]
5. Comparison of the king vision video laryngoscope with the macintosh laryngoscope.
Murphy LD; Kovacs GJ; Reardon PM; Law JA
J Emerg Med; 2014 Aug; 47(2):239-46. PubMed ID: 24742495
[TBL] [Abstract][Full Text] [Related]
6. [Comparison of five video laryngoscopes and conventional direct laryngoscopy : Investigations on simple and simulated difficult airways on the intubation trainer].
Ruetzler K; Imach S; Weiss M; Haas T; Schmidt AR
Anaesthesist; 2015 Jul; 64(7):513-9. PubMed ID: 26174747
[TBL] [Abstract][Full Text] [Related]
7. Difficult airway management for novice physicians: a randomized trial comparing direct and video-assisted laryngoscopy.
Ambrosio A; Pfannenstiel T; Bach K; Cornelissen C; Gaconnet C; Brigger MT
Otolaryngol Head Neck Surg; 2014 May; 150(5):775-8. PubMed ID: 24477825
[TBL] [Abstract][Full Text] [Related]
8. [Clinical study of SMT-Ⅱ video laryngoscope with difficult airway intubation in emergency department].
Yu JH; Wang Y
Zhonghua Wai Ke Za Zhi; 2017 Jul; 55(7):549-553. PubMed ID: 28655086
[No Abstract] [Full Text] [Related]
9. Comparison of video, optical, and direct laryngoscopy by experienced tactical paramedics.
Yun BJ; Brown CA; Grazioso CJ; Pozner CN; Raja AS
Prehosp Emerg Care; 2014; 18(3):442-5. PubMed ID: 24460509
[TBL] [Abstract][Full Text] [Related]
10. Should the Glidescope video laryngoscope be used first line for all oral intubations or only in those with a difficult airway? A review of current literature.
Russell TM; Hormis A;
J Perioper Pract; 2018 Dec; 28(12):322-333. PubMed ID: 30035689
[TBL] [Abstract][Full Text] [Related]
11. A comparison of McGrath MAC® and standard direct laryngoscopy in simulated immobilized cervical spine pediatric intubation: a manikin study.
Madziala M; Smereka J; Dabrowski M; Leung S; Ruetzler K; Szarpak L
Eur J Pediatr; 2017 Jun; 176(6):779-786. PubMed ID: 28429117
[TBL] [Abstract][Full Text] [Related]
12. Airway Management in Disaster Response: A Manikin Study Comparing Direct and Video Laryngoscopy for Endotracheal Intubation by Prehospital Providers in Level C Personal Protective Equipment.
Yousif S; Machan JT; Alaska Y; Suner S
Prehosp Disaster Med; 2017 Aug; 32(4):352-356. PubMed ID: 28318455
[TBL] [Abstract][Full Text] [Related]
13. Improvement in glottic visualisation by using the C-MAC PM video laryngoscope as a first-line device for out-of-hospital emergency tracheal intubation: An observational study.
Hossfeld B; Frey K; Doerges V; Lampl L; Helm M
Eur J Anaesthesiol; 2015 Jun; 32(6):425-31. PubMed ID: 25886716
[TBL] [Abstract][Full Text] [Related]
14. A deliberately restricted laryngeal view with the GlideScope® video laryngoscope is associated with faster and easier tracheal intubation when compared with a full glottic view: a randomized clinical trial.
Gu Y; Robert J; Kovacs G; Milne AD; Morris I; Hung O; MacQuarrie K; Mackinnon S; Adam Law J
Can J Anaesth; 2016 Aug; 63(8):928-37. PubMed ID: 27090535
[TBL] [Abstract][Full Text] [Related]
15. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
[TBL] [Abstract][Full Text] [Related]
16. Improved success rates using videolaryngoscopy in unexperienced users: a randomized crossover study in airway manikins.
Eismann H; Sieg L; Etti N; Friedrich L; Schröter C; Mommsen P; Krettek C; Zeckey C
Eur J Med Res; 2017 Aug; 22(1):27. PubMed ID: 28797305
[TBL] [Abstract][Full Text] [Related]
17. Comparison of three video laryngoscopes and direct laryngoscopy for emergency endotracheal intubation: a retrospective cohort study.
Suzuki K; Kusunoki S; Tanigawa K; Shime N
BMJ Open; 2019 Mar; 9(3):e024927. PubMed ID: 30928937
[TBL] [Abstract][Full Text] [Related]
18. Success rates and endotracheal tube insertion times of experienced emergency physicians using five video laryngoscopes: a randomised trial in a simulated trapped car accident victim.
Wetsch WA; Carlitscheck M; Spelten O; Teschendorf P; Hellmich M; Genzwürker HV; Hinkelbein J
Eur J Anaesthesiol; 2011 Dec; 28(12):849-58. PubMed ID: 21986981
[TBL] [Abstract][Full Text] [Related]
19. Comparison of 3 video laryngoscopes with the Macintosh in a manikin with easy and difficult simulated airways.
Wang PK; Huang CC; Lee Y; Chen TY; Lai HY
Am J Emerg Med; 2013 Feb; 31(2):330-8. PubMed ID: 23158595
[TBL] [Abstract][Full Text] [Related]
20. A comparison of the Truview PCD and the GlideScope Cobalt AVL video-laryngoscopes to the Miller blade for successfully intubating manikins simulating normal and difficult pediatric airways.
Hippard HK; Kalyani G; Olutoye OA; Mann DG; Watcha MF
Paediatr Anaesth; 2016 Jun; 26(6):613-20. PubMed ID: 27083381
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]