These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 2107043)

  • 21. The Reflotron Total Cholesterol assay in heparinized venous and capillary blood.
    Boerma GJ; Liem TL; Jacobs-de Haas JA; de Jong-van Staveren FA; Verbree W; Eman I
    J Clin Chem Clin Biochem; 1990 Apr; 28(4):255-8. PubMed ID: 2358795
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect on results of temperature at which Reflotron strips are stored.
    Koller PU
    Clin Chem; 1989 Jan; 35(1):186. PubMed ID: 2910569
    [No Abstract]   [Full Text] [Related]  

  • 23. How accurately does the Reflotron dry-chemistry system measure plasma total cholesterol levels when used a community-screening device.
    Phillips S; Wyndham L; Shaw J; Walker SF
    Med J Aust; 1988 Aug; 149(3):122-5. PubMed ID: 3398798
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of extreme humidity and temperature on Seralyzer and Reflotron test strips.
    Nanji AA; Poon R; Hinberg I
    Clin Chem; 1988 Jan; 34(1):178. PubMed ID: 3338159
    [No Abstract]   [Full Text] [Related]  

  • 25. Effect of not allowing Reflotron strips to warm to room temperature.
    Nanji AA; Poon R; Hinberg I
    Clin Chem; 1988 Jan; 34(1):179-80. PubMed ID: 3338161
    [No Abstract]   [Full Text] [Related]  

  • 26. How accurate is the Reflotron cholesterol analyzer? 1. Accuracy of reflotron misrepresented in study.
    van Beurden E; James R
    Am J Public Health; 1993 Mar; 83(3):428-9. PubMed ID: 8438986
    [No Abstract]   [Full Text] [Related]  

  • 27. Audit of near patient cholesterol testing in occupational health clinics.
    Majeed FA; Turner HJ; Stuart JM; Cooper RD; Laite PA
    Occup Med (Lond); 1993 Feb; 43(1):23-6. PubMed ID: 8422442
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [An evaluation of the Reflotron portable analyzer for cholesterol determination in primary care].
    Torres Garrido M; Aragonès Benaiges E; Sarrà Manetas N; Vives Ballester JA; Gutiérrez Mendoza I; Borràs Martínez P; Gómez Sorribes A
    Aten Primaria; 1990 May; 7 Spec No():34-7. PubMed ID: 2104170
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [The evaluation of apparatus for measuring capillary cholesterol].
    Menéndez Villalva C; Nuñez Losada C; Gayoso Diz P; Diz Fernández F
    Aten Primaria; 1997; 20(3):156-7. PubMed ID: 9303678
    [No Abstract]   [Full Text] [Related]  

  • 30. [Evaluation of the Accutrend GC for cholesterol determination].
    Aragonès Benaiges E
    Aten Primaria; 1996 Nov; 18(9):528, 530-1. PubMed ID: 9280451
    [No Abstract]   [Full Text] [Related]  

  • 31. Reflotron performance in a community screening program: results of the Massachusetts Model Systems for Blood Cholesterol Screening Project.
    Havas S; Bishop R; Koumjian L; Reisman J; Wozenski S
    Am J Prev Med; 1991; 7(6):397-405. PubMed ID: 1790049
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Three-minute whole-blood cholesterol screening test evaluated.
    Pradella M; Mantovani G; Sirianni F; Burlina A
    Clin Chem; 1990 Nov; 36(11):1994-5. PubMed ID: 2242590
    [No Abstract]   [Full Text] [Related]  

  • 33. Quality assessment of the Reflotron System. A blood chemistry reagent strip analyser.
    Zafar MN; Marfani R; Sardar L; Khursheed P; Syed S
    J Pak Med Assoc; 1988 Aug; 38(8):205-8. PubMed ID: 3149310
    [No Abstract]   [Full Text] [Related]  

  • 34. Measurement of bilirubin, cholesterol and creatinine in serum and plasma, by solid-phase reflectance spectroscopy.
    Stevens JF; Tsang W; Newall RG
    J Clin Pathol; 1983 May; 36(5):598-601. PubMed ID: 6841652
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A multicentre study of the new Reflotron system for the measurement of urea, glucose, triacylglycerols, cholesterol, gamma-glutamyltransferase and haemoglobin.
    Price CP; Koller PU
    J Clin Chem Clin Biochem; 1988 Apr; 26(4):233-50. PubMed ID: 2900287
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Quality of plasma cholesterol measurements in primary care.
    Broughton PM; Bullock DG; Cramb R
    BMJ; 1989 Feb; 298(6669):297-8. PubMed ID: 2493904
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Measurement of capillary cholesterol as an aid to the management of hypertensive patients with hyperlipidaemia--an assessment of the Reflotron.
    Curzio JL; Farish E; Howie C; Kennedy SS; Barnes J; Reid JJ
    J Hum Hypertens; 1992 Jun; 6(3):185-8. PubMed ID: 1629886
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Measurement of cholesterol in capillary blood using the Reflotron system. Results from approximately 1,000 comparisons with reference measurements of cholesterol in venous serum].
    Gerdes LU; Bak AM; Faergeman O
    Ugeskr Laeger; 1990 Jun; 152(24):1739-43. PubMed ID: 2360292
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of test strips for the rapid identification of ethylenediaminetetraacetic acid (EDTA) specimens.
    Scholes KL; La'ulu SL; Ence AT; Logan HL; Parker RL; Strathmann FG; Genzen JR
    Lab Med; 2015; 46(2):97-108. PubMed ID: 25918188
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Dry chemistry of reagent strips].
    Colombo JP
    Schweiz Med Wochenschr; 1987 May; 117(22):833-40. PubMed ID: 3602972
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.