BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 21071280)

  • 1. The pitfalls of BladderScan™ PVR in evaluating bladder volume in adolescent females.
    Elsamra SE; Gordon Z; Ellsworth PI
    J Pediatr Urol; 2011 Feb; 7(1):95-7. PubMed ID: 21071280
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cystic pelvic pathology presenting as falsely elevated post-void residual urine measured by portable ultrasound bladder scanning: report of 3 cases and review of the literature.
    Cooperberg MR; Chambers SK; Rutherford TJ; Foster HE
    Urology; 2000 Apr; 55(4):590. PubMed ID: 10754180
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Postvoid residual urine in women with stress incontinence.
    Tseng LH; Liang CC; Chang YL; Lee SJ; Lloyd LK; Chen CK
    Neurourol Urodyn; 2008; 27(1):48-51. PubMed ID: 17563112
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of post-void residual urine volume measurement using a portable ultrasound bladder scanner with real-time pre-scan imaging.
    Park YH; Ku JH; Oh SJ
    Neurourol Urodyn; 2011 Mar; 30(3):335-8. PubMed ID: 20658544
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Is it possible to predict post-residual voided urine by bladder scan before uroflowmetry--a useful and timesaving test to reduce the number of non--evaluable uroflow measurements?
    Dicuio M; Vesely S; Knutson T; Damber JE; Cuzzocrea DE; Dahlstrand C
    Arch Ital Urol Androl; 2010 Jun; 82(2):100-4. PubMed ID: 20812533
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of Post-Void Residual Urine Volume Measurement Using an Ultrasound Bladder Scanner among Postoperative Radical Hysterectomy Patients.
    Thanagumtorn K
    J Med Assoc Thai; 2016 Oct; 99(10):1061-6. PubMed ID: 29952185
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Use in daily urological practice of an ultrasound device for measuring bladder volume].
    Roupret M; Chartier-Kastler E; Hopirtean V; Barret E; Haertig A; Richard F
    Presse Med; 2003 May; 32(17):776-80. PubMed ID: 12856322
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of residual fraction instead of residual volume in the evaluation of lower urinary tract symptoms.
    Memon A; Ather MH
    Tech Urol; 2000 Mar; 6(1):26-8. PubMed ID: 10708144
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Falsely elevated postvoid residual urine in pregnant women.
    Tan TL; Logue E; Griffiths D; Resnick NM
    Neurourol Urodyn; 2003; 22(3):261-2. PubMed ID: 12707879
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improving Postoperative Efficiency: An Algorithm for Expedited Void Trials After Urogynecologic Surgery.
    Meekins AR; Siddiqui NY; Amundsen CL; Kuchibhatla M; Dieter AA
    South Med J; 2017 Dec; 110(12):785-790. PubMed ID: 29197314
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of post-void residual urine.
    Asimakopoulos AD; De Nunzio C; Kocjancic E; Tubaro A; Rosier PF; Finazzi-Agrò E
    Neurourol Urodyn; 2016 Jan; 35(1):55-7. PubMed ID: 25251215
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement.
    Majima T; Oota Y; Matsukawa Y; Funahashi Y; Kato M; Mimata H; Gotoh M
    Investig Clin Urol; 2020 Nov; 61(6):613-618. PubMed ID: 33135404
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A case of neurogenic bladder patient whose pre-void bladder capacity was correlated with the post-void residual volume].
    Kuroda S; Noguchi K; Takahashi T; Nakamura M; Kawai M; Murai T; Murai M
    Hinyokika Kiyo; 2014 Jun; 60(6):287-90. PubMed ID: 25001645
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Determination of residual urine volume using a portable ultrasound apparatus in a rehabilitation center for spinal lesions].
    Vavra-Hadziahmetović N; Muftić M
    Med Arh; 2003; 57(3):165-7. PubMed ID: 12858657
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bladder emptying assessment in stroke patients.
    Garrett VE; Scott JA; Costich J; Aubrey DL; Gross J
    Arch Phys Med Rehabil; 1989 Jan; 70(1):41-3. PubMed ID: 2916918
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Accuracy of Portable Ultrasound Bladder Scanner Measurements of Postvoid Residual Volume in Women With Pelvic Organ Prolapse.
    Theisen JG; Deveneau NE; Agrawal A; Kinman C; Gaskins J; Meriwether K; Francis SL
    Female Pelvic Med Reconstr Surg; 2019; 25(5):388-391. PubMed ID: 29424755
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of bladder scanning in the assessment of postvoid residual volume.
    Al-Shaikh G; Larochelle A; Campbell CE; Schachter J; Baker K; Pascali D
    J Obstet Gynaecol Can; 2009 Jun; 31(6):526-532. PubMed ID: 19646318
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of Bladder Scanner for the Assessment of Postvoid Residual Volumes in Women With Pelvic Organ Prolapse.
    Taylor DL; Sierra T; Duenas-Garcia OF; Kim Y; Leung K; Hall C; Flynn MK
    Female Pelvic Med Reconstr Surg; 2020 Oct; 26(10):640-643. PubMed ID: 30325783
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Urodynamic evaluation of the bladder and pelvic floor.
    Bradley CS; Smith KE; Kreder KJ
    Gastroenterol Clin North Am; 2008 Sep; 37(3):539-52, vii. PubMed ID: 18793995
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Large voided volume suggestive of abnormal uroflow pattern and elevated post-void residual urine.
    Chang SJ; Yang SS; Chiang IN
    Neurourol Urodyn; 2011 Jan; 30(1):58-61. PubMed ID: 20623612
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.