These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
164 related articles for article (PubMed ID: 21073515)
1. Accuracy of handheld echocardiography for bedside diagnostic evaluation in a tertiary cardiology center: comparison with standard echocardiography. Giusca S; Jurcut R; Ticulescu R; Dumitru D; Vladaia A; Savu O; Voican A; Popescu BA; Ginghina C Echocardiography; 2011 Feb; 28(2):136-41. PubMed ID: 21073515 [TBL] [Abstract][Full Text] [Related]
2. Hand-carried ultrasound performed at bedside in cardiology inpatient setting - a comparative study with comprehensive echocardiography. Tsutsui JM; Maciel RR; Costa JM; Andrade JL; Ramires JF; Mathias W Cardiovasc Ultrasound; 2004 Nov; 2():24. PubMed ID: 15548326 [TBL] [Abstract][Full Text] [Related]
3. Diagnostic capability of comprehensive handheld vs transthoracic echocardiography. Cullen MW; Blauwet LA; Vatury OM; Mulvagh SL; Behrenbeck TR; Scott CG; Pellikka PA Mayo Clin Proc; 2014 Jun; 89(6):790-8. PubMed ID: 24684783 [TBL] [Abstract][Full Text] [Related]
4. Diagnostic performance of handheld echocardiography for the assessment of basic cardiac morphology and function: a validation study in routine cardiac patients. Prinz C; Dohrmann J; van Buuren F; Bitter T; Bogunovic N; Horstkotte D; Faber L Echocardiography; 2012 Sep; 29(8):887-94. PubMed ID: 22639856 [TBL] [Abstract][Full Text] [Related]
5. Handheld echocardiography during hospitalization for acute myocardial infarction. Cullen MW; Geske JB; Anavekar NS; Askew JW; Lewis BR; Oh JK Clin Cardiol; 2017 Nov; 40(11):993-999. PubMed ID: 28724192 [TBL] [Abstract][Full Text] [Related]
7. Feasibility and accuracy of speckle tracking echocardiography in emergency department patients. Reardon L; Scheels WJ; Singer AJ; Reardon RF Am J Emerg Med; 2018 Dec; 36(12):2254-2259. PubMed ID: 30322665 [TBL] [Abstract][Full Text] [Related]
8. Diagnostic accuracy of pocket-size handheld echocardiographs used by cardiologists in the acute care setting. Testuz A; Müller H; Keller PF; Meyer P; Stampfli T; Sekoranja L; Vuille C; Burri H Eur Heart J Cardiovasc Imaging; 2013 Jan; 14(1):38-42. PubMed ID: 22535657 [TBL] [Abstract][Full Text] [Related]
9. A Novel Handheld Echocardiography Device with Continuous-Wave Doppler Capability: Implications for the Evaluation of Aortic Stenosis Severity. Sachpekidis V; Papadopoulou SL; Kantartzi V; Styliadis I; Nihoyannopoulos P J Am Soc Echocardiogr; 2022 Dec; 35(12):1273-1280. PubMed ID: 36058491 [TBL] [Abstract][Full Text] [Related]
10. Comparison of effectiveness of hand-carried ultrasound to bedside cardiovascular physical examination. Kobal SL; Trento L; Baharami S; Tolstrup K; Naqvi TZ; Cercek B; Neuman Y; Mirocha J; Kar S; Forrester JS; Siegel RJ Am J Cardiol; 2005 Oct; 96(7):1002-6. PubMed ID: 16188532 [TBL] [Abstract][Full Text] [Related]
11. The importance of training in echocardiography: a validation study using pocket echocardiography. Prinz C; Dohrmann J; van Buuren F; Bitter T; Bogunovic N; Horstkotte D; Faber L J Cardiovasc Med (Hagerstown); 2012 Nov; 13(11):700-7. PubMed ID: 22929564 [TBL] [Abstract][Full Text] [Related]
12. Brief group training of medical students in focused cardiac ultrasound may improve diagnostic accuracy of physical examination. Stokke TM; Ruddox V; Sarvari SI; Otterstad JE; Aune E; Edvardsen T J Am Soc Echocardiogr; 2014 Nov; 27(11):1238-46. PubMed ID: 25216765 [TBL] [Abstract][Full Text] [Related]
13. Hand-held echocardiography in the setting of pre-operative cardiac evaluation of patients undergoing non-cardiac surgery: results from a randomized pilot study. Cavallari I; Mega S; Goffredo C; Patti G; Chello M; Di Sciascio G Int J Cardiovasc Imaging; 2015 Jun; 31(5):995-1000. PubMed ID: 25985940 [TBL] [Abstract][Full Text] [Related]
14. Diagnostic utility and clinical usefulness of the pocket echocardiographic device. Michalski B; Kasprzak JD; Szymczyk E; Lipiec P Echocardiography; 2012; 29(1):1-6. PubMed ID: 22044766 [TBL] [Abstract][Full Text] [Related]
15. Hand-held echocardiographic examination of patients with symptoms of acute coronary syndromes in the emergency department: the 30-day outcome associated with normal left ventricular wall motion. Weston P; Alexander JH; Patel MR; Maynard C; Crawford L; Wagner GS Am Heart J; 2004 Dec; 148(6):1096-101. PubMed ID: 15632899 [TBL] [Abstract][Full Text] [Related]
16. Can hospital rounds with pocket ultrasound by cardiologists reduce standard echocardiography? Khan HA; Wineinger NE; Uddin PQ; Mehta HS; Rubenson DS; Topol EJ Am J Med; 2014 Jul; 127(7):669.e1-7. PubMed ID: 24674919 [TBL] [Abstract][Full Text] [Related]
17. Feasibility of point-of-care echocardiography by internal medicine house staff. Alexander JH; Peterson ED; Chen AY; Harding TM; Adams DB; Kisslo JA Am Heart J; 2004 Mar; 147(3):476-81. PubMed ID: 14999197 [TBL] [Abstract][Full Text] [Related]
18. The diagnostic accuracy of pocket-size cardiac ultrasound performed by unselected residents with minimal training. Ruddox V; Stokke TM; Edvardsen T; Hjelmesæth J; Aune E; Bækkevar M; Norum IB; Otterstad JE Int J Cardiovasc Imaging; 2013 Dec; 29(8):1749-57. PubMed ID: 23974908 [TBL] [Abstract][Full Text] [Related]