BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 21081887)

  • 1. Monte Carlo investigation of energy response of various detector materials in ¹²⁵I and ¹⁶⁹Yb brachytherapy dosimetry.
    Selvam TP; Keshavkumar B
    J Appl Clin Med Phys; 2010 Jul; 11(4):3282. PubMed ID: 21081887
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo-based beam quality and phantom scatter corrections for solid-state detectors in 60Co and 192Ir brachytherapy dosimetry.
    Subhalaxmi M; Selvam TP
    J Appl Clin Med Phys; 2014 Nov; 15(6):4907. PubMed ID: 25493516
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Phantom scatter corrections of radiochromic films in high-energy brachytherapy dosimetry: a Monte Carlo study.
    Subhalaxmi M; Palani Selvam T
    Radiol Phys Technol; 2015 Jul; 8(2):215-23. PubMed ID: 25753500
    [TBL] [Abstract][Full Text] [Related]  

  • 4. EGSnrc-based depth-dependent photon energy response and phantom scatter corrections for low-energy brachytherapy sources.
    Mishra S; Selvam TP
    Radiol Phys Technol; 2020 Sep; 13(3):256-267. PubMed ID: 32816228
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monte Carlo calculation of beam quality correction for solid-state detectors and phantom scatter correction at 137Cs energy.
    Selvam TP; Mishra S; Vishwakarma RS
    J Appl Clin Med Phys; 2014 Jan; 15(1):4445. PubMed ID: 24423840
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources.
    Melhus CS; Rivard MJ
    Med Phys; 2006 Jun; 33(6):1729-37. PubMed ID: 16872080
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate
    Kaveckyte V; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2018 Jan; 45(1):429-437. PubMed ID: 29171060
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo-based investigation of absorbed-dose energy dependence of radiochromic films in high energy brachytherapy dosimetry.
    Subhalaxmi M; Selvam TP
    J Appl Clin Med Phys; 2014 Jan; 15(1):4448. PubMed ID: 24423841
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo Calculation of Beam Quality and Phantom Scatter Corrections for Lithium Formate Electron Paramagnetic Resonance Dosimeter for High-energy Brachytherapy Dosimetry.
    Mishra S; Selvam TP
    J Med Phys; 2017; 42(2):72-79. PubMed ID: 28706352
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
    Kaveckyte V; Persson L; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2020 Mar; 47(3):1268-1279. PubMed ID: 31880809
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of solid phantoms with water for dosimetry of 125I brachytherapy sources.
    Meigooni AS; Meli JA; Nath R
    Med Phys; 1988; 15(5):695-701. PubMed ID: 3185404
    [TBL] [Abstract][