BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 21085805)

  • 1. Comparative study of two commercially pure titanium casting methods.
    Rodrigues RC; Faria AC; Orsi IA; Mattos Mda G; Macedo AP; Ribeiro RF
    J Appl Oral Sci; 2010; 18(5):487-92. PubMed ID: 21085805
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures.
    Rodrigues RC; Ribeiro RF; de Mattos Mda G; Bezzon OL
    J Prosthet Dent; 2002 Sep; 88(3):290-6. PubMed ID: 12426499
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of titanium and cobalt-chromium removable partial denture clasps.
    Bridgeman JT; Marker VA; Hummel SK; Benson BW; Pace LL
    J Prosthet Dent; 1997 Aug; 78(2):187-93. PubMed ID: 9260137
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Retention force of T-bar clasps for titanium and cobalt-chromium removable partial dentures.
    Rodrigues RC; Macedo AP; de Torres EM; de Mattos Mda G; Ribeiro RF
    Braz Dent J; 2008; 19(3):209-13. PubMed ID: 18949292
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps.
    Kim D; Park C; Yi Y; Cho L
    J Prosthet Dent; 2004 Apr; 91(4):374-82. PubMed ID: 15116040
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retention strength of cobalt-chromium vs nickel-chromium titanium vs CP titanium in a cast framework association of removable partial overdenture.
    Souza JE; Silva NR; Coelho PG; Zavanelli AC; Ferracioli RC; Zavanelli RA
    J Contemp Dent Pract; 2011 May; 12(3):179-86. PubMed ID: 22186813
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Feasibility study and material selection for powder-bed fusion process in printing of denture clasps.
    Ma K; Chen H; Shen Y; Guo Y; Li W; Wang Y; Zhang Y; Sun Y
    Comput Biol Med; 2023 May; 157():106772. PubMed ID: 36963354
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting].
    Ma KN; Chen H; Shen YR; Zhou YS; Wang Y; Sun YC
    Beijing Da Xue Xue Bao Yi Xue Ban; 2022 Feb; 54(1):105-112. PubMed ID: 35165476
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fabrication of titanium removable dental prosthesis frameworks with a 2-step investment coating method.
    Koike M; Hummel SK; Ball JD; Okabe T
    J Prosthet Dent; 2012 Jun; 107(6):393-9. PubMed ID: 22633596
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks.
    Jang KS; Youn SJ; Kim YS
    J Prosthet Dent; 2001 Jul; 86(1):93-8. PubMed ID: 11458267
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the retentive characteristics of cobalt-chromium and commercially pure titanium clasps using a novel method.
    Tse ET; Cheng LY; Luk HW; Chu FC; Chai J; Chow TW
    Int J Prosthodont; 2006; 19(4):371-2. PubMed ID: 16900820
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Over-refractory casting technique as an alternative to one-piece multi-unit fixed partial denture frameworks.
    de Oliveira Correa G; Henriques GE; Mesquita MF; Sobrinho LC
    J Prosthet Dent; 2006 Mar; 95(3):243-8. PubMed ID: 16543023
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: a comparative in vitro study.
    Tan FB; Song JL; Wang C; Fan YB; Dai HW
    J Prosthodont Res; 2019 Jan; 63(1):58-65. PubMed ID: 30309743
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of casting technique on surface roughness and consequent mass loss after polishing of NiCr and CoCr base metal alloys: a comparative study with titanium.
    Bezzon OL; Pedrazzi H; Zaniquelli O; da Silva TB
    J Prosthet Dent; 2004 Sep; 92(3):274-7. PubMed ID: 15343163
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of arm design and chemical polishing on retentive force of cast titanium alloy clasps.
    Shimpo H
    J Prosthodont; 2008 Jun; 17(4):300-7. PubMed ID: 18205738
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fitness accuracy and retentive forces of additive manufactured titanium clasp.
    Takahashi K; Torii M; Nakata T; Kawamura N; Shimpo H; Ohkubo C
    J Prosthodont Res; 2020 Oct; 64(4):468-477. PubMed ID: 32063534
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An analytical model to design circumferential clasps for laser-sintered removable partial dentures.
    Alsheghri AA; Alageel O; Caron E; Ciobanu O; Tamimi F; Song J
    Dent Mater; 2018 Oct; 34(10):1474-1482. PubMed ID: 29937332
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Internal porosity of cast titanium removable partial dentures: Influence of sprue direction on porosity in circumferential clasps of a clinical framework design.
    Baltag I; Watanabe K; Kusakari H; Miyakawa O
    J Prosthet Dent; 2002 Aug; 88(2):151-8. PubMed ID: 12397242
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fitness accuracy and retentive forces of milled titanium clasp.
    Maruo R; Shimpo H; Kimoto K; Hayakawa T; Miura H; Ohkubo C
    Dent Mater J; 2022 May; 41(3):414-420. PubMed ID: 35135942
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp.
    Yoda N; Yokoyama M; Adachi G; Takahashi M; Sasaki K
    Int J Prosthodont; 2010; 23(1):38-41. PubMed ID: 20234890
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.