BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

239 related articles for article (PubMed ID: 21089762)

  • 1. Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.
    Wang LL; Klein D; Beddar AS
    Med Phys; 2010 Oct; 37(10):5279-86. PubMed ID: 21089762
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations.
    Wang LL; Beddar S
    Med Phys; 2011 Mar; 38(3):1596-9. PubMed ID: 21520871
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.
    Lessard F; Archambault L; Plamondon M; Despres P; Therriault-Proulx F; Beddar S; Beaulieu L
    Med Phys; 2012 Sep; 39(9):5308-16. PubMed ID: 22957599
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.
    Guillot M; Beaulieu L; Archambault L; Beddar S; Gingras L
    Med Phys; 2011 Dec; 38(12):6763-74. PubMed ID: 22149858
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A systematic characterization of the low-energy photon response of plastic scintillation detectors.
    Boivin J; Beddar S; Bonde C; Schmidt D; Culberson W; Guillemette M; Beaulieu L
    Phys Med Biol; 2016 Aug; 61(15):5569-86. PubMed ID: 27384872
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.
    Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE
    Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Response of plastic scintillators to low-energy photons.
    Peralta L; Rêgo F
    Phys Med Biol; 2014 Aug; 59(16):4621-33. PubMed ID: 25079252
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Energy dependence of a scintillating fiber detector for preclinical dosimetry with an image guided micro-irradiator.
    Le Deroff C; Frelin AM; Ledoux X
    Phys Med Biol; 2019 May; 64(11):115015. PubMed ID: 30974415
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Poster - Thurs Eve-37: Energy and irradiation modality independence of calibration coefficients for water equivalent plastic scintillation detectors in the megavoltage range.
    Guillot M; Lacroix F; Thériault F; Beaulieu L; Gingras L
    Med Phys; 2008 Jul; 35(7Part2):3408. PubMed ID: 28512804
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.
    Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M
    Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of plastic scintillating fibres to surface dosimetry in megavoltage photon and electron beams: considerations for Cerenkov correction.
    Monajemi TT; Ruiz EA
    Phys Med Biol; 2018 Sep; 63(18):185003. PubMed ID: 30101759
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.
    Guillot M; Gingras L; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2011 Apr; 38(4):2140-50. PubMed ID: 21626947
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
    Kaveckyte V; Persson L; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2020 Mar; 47(3):1268-1279. PubMed ID: 31880809
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.
    Klein DM; Tailor RC; Archambault L; Wang L; Therriault-Proulx F; Beddar AS
    Med Phys; 2010 Oct; 37(10):5541-9. PubMed ID: 21089789
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams.
    Wang LL; Perles LA; Archambault L; Sahoo N; Mirkovic D; Beddar S
    Phys Med Biol; 2012 Dec; 57(23):7767-81. PubMed ID: 23128412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.
    Papaconstadopoulos P; Archambault L; Seuntjens J
    Med Phys; 2017 Feb; 44(2):654-664. PubMed ID: 27997030
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Temperature dependence of BCF plastic scintillation detectors.
    Wootton L; Beddar S
    Phys Med Biol; 2013 May; 58(9):2955-67. PubMed ID: 23574889
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characteristics of a plastic scintillation detector in photon beam dosimetry.
    Das IJ; Sohn JJ; Lim SN; Sengupta B; Feijoo M; Yadav P
    J Appl Clin Med Phys; 2024 Jan; 25(1):e14209. PubMed ID: 37983685
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fabrication and characterization of a stemless plastic scintillation detector.
    Hupman MA; Monajemi T; Valitova I; Hill IG; Syme A
    Med Phys; 2020 Nov; 47(11):5882-5889. PubMed ID: 32966652
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.