These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 2109058)

  • 1. Stereoselective determination of flecainide in human plasma by high-performance liquid chromatography with fluorescence detection.
    Turgeon J; Kroemer HK; Prakash C; Blair IA; Roden DM
    J Pharm Sci; 1990 Feb; 79(2):91-5. PubMed ID: 2109058
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-performance liquid chromatographic determination of the enantiomers of flecainide in human plasma and urine.
    Alessi-Severini S; Jamali F; Pasutto FM; Coutts RT; Gulamhusein S
    J Pharm Sci; 1990 Mar; 79(3):257-60. PubMed ID: 2110973
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stereoselective determination of unchanged and glucuroconjugated eliprodil, a new anti-ischaemic drug, in human plasma and urine by precolumn derivatization and column-switching high-performance liquid chromatography with fluorescence detection.
    Malavasi B; Ripamonti M; Rouchouse A; Ascalone V
    J Chromatogr A; 1996 Apr; 729(1-2):323-33. PubMed ID: 9004957
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-performance liquid chromatographic assay of flecainide and its enantiomers in serum.
    Lie-A-Huen L; Stuurman RM; Ijdenberg FN; Kingma JH; Meijer DK
    Ther Drug Monit; 1989 Nov; 11(6):708-11. PubMed ID: 2512696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stereoselective high-performance liquid chromatographic assay for the determination of sotalol enantiomers in biological fluids.
    Fiset C; Philippon F; Gilbert M; Turgeon J
    J Chromatogr; 1993 Feb; 612(2):231-7. PubMed ID: 8468381
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of concentrations of flecainide in human serum by high-performance liquid chromatography on a fluorocarbon-bonded silica gel column.
    Obayashi M; Kosugi T; Yamazaki J; Matsumoto Y; Fukuoka M; Matsumoto M
    J Chromatogr B Biomed Sci Appl; 1999 Apr; 726(1-2):219-23. PubMed ID: 10348189
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-performance liquid chromatographic determination of (SR)- and (RS)-enantiomers of mefloquine in plasma and capillary blood sampled on paper after derivatization with (-)-1-(9-fluorenyl)ethyl chloroformate.
    Bergqvist Y; Doverskog M; Kabbani JA
    J Chromatogr; 1994 Jan; 652(1):73-81. PubMed ID: 8014230
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simple high-performance liquid chromatographic method for the routine measurement of flecainide in plasma.
    Grgurinovich N
    J Anal Toxicol; 1988; 12(1):38-41. PubMed ID: 3127637
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High performance liquid chromatography for routine monitoring of serum flecainide.
    Nakagawa R; Homma M; Kuga K; Yamaguchi I; Kobayashi D; Morimoto Y; Kohda Y
    J Pharm Biomed Anal; 2002 Aug; 30(1):171-4. PubMed ID: 12151077
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stereoselective analysis of flecainide enantiomers using reversed-phase liquid chromatography for assessing CYP2D6 activity.
    Doki K; Sekiguchi Y; Kuga K; Aonuma K; Kohda Y; Homma M
    Biomed Chromatogr; 2014 Sep; 28(9):1193-8. PubMed ID: 24523024
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-performance liquid chromatographic analysis of methocarbamol enantiomers in biological fluids.
    Alessi-Severini S; Coutts RT; Jamali F; Pasutto FM
    J Chromatogr; 1992 Nov; 582(1-2):173-9. PubMed ID: 1491037
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of a bonded-phase extraction column for rapid sample preparation of flecainide from human plasma for high-performance liquid chromatographic analysis--fluorescence or ultraviolet detection.
    Chang SF; Miller AM; Fox JM; Welscher TM
    Ther Drug Monit; 1984; 6(1):105-11. PubMed ID: 6710553
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An improved HPLC-fluorescence stereoselective method for analysis of (+)-S- and (-)-R-sotalol enantiomers in plasma sample.
    da Cunha LC; Gondim FA; de Paola AA; Barros IC; Santos SR
    Boll Chim Farm; 2001; 140(6):448-54. PubMed ID: 11822237
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assay of tocainide enantiomers in plasma by solid-phase extraction and indirect chiral high-performance liquid chromatography after derivatization with (-)-menthyl chloroformate.
    Christensen EB; Hansen SH; Rasmussen SN
    J Chromatogr B Biomed Appl; 1995 Aug; 670(2):243-9. PubMed ID: 8548014
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of flecainide plasma concentrations by high performance liquid chromatography with fluorescence detection.
    Plomp TA; Boom HT; Maes RA
    J Anal Toxicol; 1986; 10(3):102-6. PubMed ID: 3724068
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stereoselective determination of cisapride, a prokinetic agent, in human plasma by chiral high-performance liquid chromatography with ultraviolet detection: application to pharmacokinetic study.
    Desta Z; Soukhova NV; Morocho A; Park J; Mahal SK; Flockhart DA
    J Chromatogr B Biomed Sci Appl; 2000 Jul; 744(2):263-72. PubMed ID: 10993514
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous determination of propranolol enantiomers in plasma by high-performance liquid chromatography with fluorescence detection.
    Prakash C; Koshakji RP; Wood AJ; Blair IA
    J Pharm Sci; 1989 Sep; 78(9):771-5. PubMed ID: 2585274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stereoselective analysis of nadolol in human plasma.
    Srinivas NR; Shyu WC; Shah VR; Campbell DA; Barbhaiya RH
    Biomed Chromatogr; 1995; 9(5):226-8. PubMed ID: 8593423
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stereoselective high-performance liquid chromatographic determination of flurbiprofen in human plasma.
    Geisslinger G; Menzel-Soglowek S; Schuster O; Brune K
    J Chromatogr; 1992 Jan; 573(1):163-7. PubMed ID: 1564098
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stereoselective determination of the enantiomers of methadone in plasma using high-performance liquid chromatography.
    Schmidt N; Brune K; Geisslinger G
    J Chromatogr; 1992 Dec; 583(2):195-200. PubMed ID: 1478983
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.