These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
158 related articles for article (PubMed ID: 21091987)
21. Pulse oximetry fails to accurately detect low levels of arterial hemoglobin oxygen saturation in dogs. Sidi A; Rush W; Gravenstein N; Ruiz B; Paulus DA; Davis RF J Clin Monit; 1987 Oct; 3(4):257-62. PubMed ID: 3681359 [TBL] [Abstract][Full Text] [Related]
22. Simultaneous comparison of three noninvasive oximeters in healthy volunteers. Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041 [TBL] [Abstract][Full Text] [Related]
23. Oxygen targeting in preterm infants using the Masimo SET Radical pulse oximeter. Johnston ED; Boyle B; Juszczak E; King A; Brocklehurst P; Stenson BJ Arch Dis Child Fetal Neonatal Ed; 2011 Nov; 96(6):F429-33. PubMed ID: 21378398 [TBL] [Abstract][Full Text] [Related]
24. Effect of probe design on accuracy and reliability of pulse oximetry in pediatric patients. Bell C; Luther MA; Nicholson JJ; Fox CJ; Hirsh JL J Clin Anesth; 1999 Jun; 11(4):323-7. PubMed ID: 10470635 [TBL] [Abstract][Full Text] [Related]
25. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a conventional and two new generation oximeters. Bohnhorst B; Peter CS; Poets CF Crit Care Med; 2000 May; 28(5):1565-8. PubMed ID: 10834712 [TBL] [Abstract][Full Text] [Related]
26. Comparison of two different pulse oximeters in monitoring preterm infants. Grieve SH; McIntosh N; Laing IA Crit Care Med; 1997 Dec; 25(12):2051-4. PubMed ID: 9403758 [TBL] [Abstract][Full Text] [Related]
27. Accuracy of pulse oximeters at low oxygen saturations in children with congenital cyanotic heart disease: An observational study. Kim EH; Lee JH; Song IK; Kim HS; Jang YE; Yoo S; Kim JT Paediatr Anaesth; 2019 Jun; 29(6):597-603. PubMed ID: 30938906 [TBL] [Abstract][Full Text] [Related]
28. Longevity of Masimo and Nellcor pulse oximeter sensors in the care of infants. Erler T; Avenarius S; Wischniewski E; Schmidt K; Kläber HG J Perinatol; 2003 Mar; 23(2):133-5. PubMed ID: 12673263 [TBL] [Abstract][Full Text] [Related]
29. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia. Gehring H; Hornberger C; Matz H; Konecny E; Schmucker P Respir Care; 2002 Jan; 47(1):48-60. PubMed ID: 11749687 [TBL] [Abstract][Full Text] [Related]
30. Differences in pulse oximetry technology can affect detection of sleep-disorderd breathing in children. Brouillette RT; Lavergne J; Leimanis A; Nixon GM; Ladan S; McGregor CD Anesth Analg; 2002 Jan; 94(1 Suppl):S47-53. PubMed ID: 11900039 [TBL] [Abstract][Full Text] [Related]
31. Accuracy of the Masimo SET® LNCS neo peripheral pulse oximeter in cyanotic congenital heart disease. Griksaitis MJ; Scrimgeour GE; Pappachan JV; Baldock AJ Cardiol Young; 2016 Aug; 26(6):1183-6. PubMed ID: 26471067 [TBL] [Abstract][Full Text] [Related]
32. Identification of movement artefact by the Nellcor N-200 and N-3000 pulse oximeters. Plummer JL; Ilsley AH; Fronsko RR; Owen H J Clin Monit; 1997 Mar; 13(2):109-13. PubMed ID: 9112206 [TBL] [Abstract][Full Text] [Related]
33. Pulse oximetry during low perfusion caused by emerging pneumonia and sepsis in rabbits. Hummler HD; Pohlandt F; Franz AR Crit Care Med; 2002 Nov; 30(11):2501-8. PubMed ID: 12441761 [TBL] [Abstract][Full Text] [Related]
34. Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and Motion. Louie A; Feiner JR; Bickler PE; Rhodes L; Bernstein M; Lucero J Anesthesiology; 2018 Mar; 128(3):520-530. PubMed ID: 29200008 [TBL] [Abstract][Full Text] [Related]
35. Observing the resuscitation of very preterm infants: are we able to follow the oxygen saturation targets? Goos TG; Rook D; van der Eijk AC; Kroon AA; Pichler G; Urlesberger B; Dankelman J; Reiss IK Resuscitation; 2013 Aug; 84(8):1108-13. PubMed ID: 23376585 [TBL] [Abstract][Full Text] [Related]
36. Pulse oximetry in children with congenital heart disease: effects of cardiopulmonary bypass and cyanosis. Torres A; Skender KM; Wohrley JD; Aldag JC; Raff GW; Bysani GK; Geiss DM J Intensive Care Med; 2004; 19(4):229-34. PubMed ID: 15296623 [TBL] [Abstract][Full Text] [Related]
37. The precision and accuracy of Nellcor and Masimo oximeters at low oxygen saturations (70%) in newborn lambs. Dawson JA; Bastrenta P; Cavigioli F; Thio M; Ong T; Siew ML; Hooper SB; Davis PG Arch Dis Child Fetal Neonatal Ed; 2014 Jul; 99(4):F278-81. PubMed ID: 24596406 [TBL] [Abstract][Full Text] [Related]
38. A comparison of the failure times of pulse oximeters during blood pressure cuff-induced hypoperfusion in volunteers. Kawagishi T; Kanaya N; Nakayama M; Kurosawa S; Namiki A Anesth Analg; 2004 Sep; 99(3):793-796. PubMed ID: 15333413 [TBL] [Abstract][Full Text] [Related]
39. Automated adjustments of inspired fraction of oxygen to avoid hypoxemia and hyperoxemia in neonates - a systematic review on clinical studies. Hummler H; Fuchs H; Schmid M Klin Padiatr; 2014 Jul; 226(4):204-10. PubMed ID: 25010125 [TBL] [Abstract][Full Text] [Related]
40. Time to achieve stable pulse oximetry values in VLBW infants in the delivery room. Gandhi B; Rich W; Finer N Resuscitation; 2013 Jul; 84(7):970-3. PubMed ID: 23238422 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]