These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Microspheres aided introduction of ionophore and ion-exchanger to the ion-selective membrane. Wojciechowski M; Kisiel A; Bulska E; Michalska A Talanta; 2012 Jan; 88():66-72. PubMed ID: 22265471 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of the separate equilibrium processes that dictate the upper detection limit of neutral ionophore-based potentiometric sensors. Qin Y; Bakker E Anal Chem; 2002 Jul; 74(13):3134-41. PubMed ID: 12141674 [TBL] [Abstract][Full Text] [Related]
8. Ion selective electrode for cesium based on 5-(4'-nitrophenylazo)25,27-bis(2-propyloxy)26,28-dihydroxycalix[4]arene. Ramanjaneyulu PS; Singh P; Sayi YS; Chawla HM; Ramakumar KL J Hazard Mater; 2010 Mar; 175(1-3):1031-6. PubMed ID: 19942345 [TBL] [Abstract][Full Text] [Related]
9. Determination of cerium ion by polymeric membrane and coated graphite electrode based on novel pendant armed macrocycle. Singh AK; Singh P Anal Chim Acta; 2010 Aug; 675(2):170-80. PubMed ID: 20800729 [TBL] [Abstract][Full Text] [Related]
10. Effect of the phase volume ratio on the potential of a liquid-membrane ion-selective electrode. Samec Z; Girault HH Anal Chem; 2004 Jul; 76(14):4150-5. PubMed ID: 15253656 [TBL] [Abstract][Full Text] [Related]
11. Selectivity in the coextraction of cation and anion by electrochemically modulated liquid-liquid extraction. Berduque A; Arrigan DW Anal Chem; 2006 Apr; 78(8):2717-25. PubMed ID: 16615784 [TBL] [Abstract][Full Text] [Related]
12. Voltammetry of ion transfer across a polarized room-temperature ionic liquid membrane facilitated by valinomycin: theoretical aspects and application. Langmaier J; Samec Z Anal Chem; 2009 Aug; 81(15):6382-9. PubMed ID: 19572695 [TBL] [Abstract][Full Text] [Related]
13. Potentiometric sensor for heparin polyion: transient behavior and response mechanism. Langmaier J; Samcova E; Samec Z Anal Chem; 2007 Apr; 79(7):2892-900. PubMed ID: 17315978 [TBL] [Abstract][Full Text] [Related]
14. Determination of the leaching of polymeric ion-selective membrane components by stripping voltammetry. Paczosa-Bator B; Piech R; Lewenstam A Talanta; 2010 May; 81(3):1003-9. PubMed ID: 20298885 [TBL] [Abstract][Full Text] [Related]
15. Voltammetric ion-selective electrodes for the selective determination of cations and anions. Zhang J; Harris AR; Cattrall RW; Bond AM Anal Chem; 2010 Mar; 82(5):1624-33. PubMed ID: 20121252 [TBL] [Abstract][Full Text] [Related]
16. Polymeric membrane electrodes for selective determination of methiaden. Hopkała H; Drozd J; Kowalczuk D; Artymiak A Acta Pol Pharm; 2003; 60(3):159-62. PubMed ID: 14556481 [TBL] [Abstract][Full Text] [Related]
17. Controlling cesium cation recognition via cation metathesis within an ion pair receptor. Kim SK; Vargas-Zúñiga GI; Hay BP; Young NJ; Delmau LH; Masselin C; Lee CH; Kim JS; Lynch VM; Moyer BA; Sessler JL J Am Chem Soc; 2012 Jan; 134(3):1782-92. PubMed ID: 22191574 [TBL] [Abstract][Full Text] [Related]
18. Reverse current pulse method to restore uniform concentration profiles in ion-selective membranes. 2. Comparison of the efficiency of the different protocols. Zook JM; Lindner E Anal Chem; 2009 Jul; 81(13):5155-64. PubMed ID: 19459602 [TBL] [Abstract][Full Text] [Related]
19. On the mechanism of nitrobenzene liquid membrane oscillators containing hexadecyltrimethylammonium bromide. Szpakowska M; Czaplicka I; Nagy OB Biophys Chem; 2006 Mar; 120(2):148-53. PubMed ID: 16337732 [TBL] [Abstract][Full Text] [Related]