370 related articles for article (PubMed ID: 21094467)
1. Dural repair with four spinal sealants: focused review of the manufacturers' inserts and the current literature.
Epstein NE
Spine J; 2010 Dec; 10(12):1065-8. PubMed ID: 21094467
[TBL] [Abstract][Full Text] [Related]
2. Histological effects of fibrin glue and synthetic tissue glues on the spinal cord: are they safe to use?
Kalsi P; Thom M; Choi D
Br J Neurosurg; 2017 Dec; 31(6):695-700. PubMed ID: 28847164
[TBL] [Abstract][Full Text] [Related]
3. Study of dural suture watertightness: an in vitro comparison of different sealants.
Chauvet D; Tran V; Mutlu G; George B; Allain JM
Acta Neurochir (Wien); 2011 Dec; 153(12):2465-72. PubMed ID: 21989779
[TBL] [Abstract][Full Text] [Related]
4. Mechanical properties of surgical glues used in aortic root replacement.
Azadani AN; Matthews PB; Ge L; Shen Y; Jhun CS; Guy TS; Tseng EE
Ann Thorac Surg; 2009 Apr; 87(4):1154-60. PubMed ID: 19324142
[TBL] [Abstract][Full Text] [Related]
5. Fibrin Sealants in Dura Sealing: A Systematic Literature Review.
Esposito F; Angileri FF; Kruse P; Cavallo LM; Solari D; Esposito V; Tomasello F; Cappabianca P
PLoS One; 2016; 11(4):e0151533. PubMed ID: 27119993
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of fibrin sealants for central nervous system sealing in the mongrel dog durotomy model.
Hutchinson RW; Mendenhall V; Abutin RM; Muench T; Hart J
Neurosurgery; 2011 Oct; 69(4):921-8; discussion 929. PubMed ID: 21552173
[TBL] [Abstract][Full Text] [Related]
7. Usefulness of Sealants for Dural Closure: Evaluation in an In Vitro Model.
van Doormaal T; Kinaci A; van Thoor S; Redegeld S; Bergmann W; van der Zwan A
Oper Neurosurg (Hagerstown); 2018 Oct; 15(4):425-432. PubMed ID: 29281065
[TBL] [Abstract][Full Text] [Related]
8. Complications following decompression of Chiari malformation Type I in children: dural graft or sealant?
Parker SR; Harris P; Cummings TJ; George T; Fuchs H; Grant G
J Neurosurg Pediatr; 2011 Aug; 8(2):177-83. PubMed ID: 21806360
[TBL] [Abstract][Full Text] [Related]
9. Polyethylene glycol hydrogel spinal sealant (DuraSeal Spinal Sealant) as an adjunct to sutured dural repair in the spine: results of a prospective, multicenter, randomized controlled study.
Kim KD; Wright NM
Spine (Phila Pa 1976); 2011 Nov; 36(23):1906-12. PubMed ID: 22008746
[TBL] [Abstract][Full Text] [Related]
10. Comparative analysis of biomechanical performance of available "nerve glues".
Isaacs JE; McDaniel CO; Owen JR; Wayne JS
J Hand Surg Am; 2008; 33(6):893-9. PubMed ID: 18656762
[TBL] [Abstract][Full Text] [Related]
11. Comparative study of biological glues: cryoprecipitate glue, two-component fibrin sealant, and "French" glue.
Basu S; Marini CP; Bauman FG; Shirazian D; Damiani P; Robertazzi R; Jacobowitz IJ; Acinapura A; Cunningham JN
Ann Thorac Surg; 1995 Nov; 60(5):1255-62. PubMed ID: 8526609
[TBL] [Abstract][Full Text] [Related]
12. Use of duraseal in repair of cerebrospinal fluid leaks.
Chin CJ; Kus L; Rotenberg BW
J Otolaryngol Head Neck Surg; 2010 Oct; 39(5):594-9. PubMed ID: 20828525
[TBL] [Abstract][Full Text] [Related]
13. In vivo efficacy of a new autologous fibrin sealant.
Alston SM; Solen KA; Sukavaneshvar S; Mohammad SF
J Surg Res; 2008 May; 146(1):143-8. PubMed ID: 18279893
[TBL] [Abstract][Full Text] [Related]
14. Galea-pericranium dural closure: can we safely avoid sealants?
Giovanni S; Della Pepa GM; La Rocca G; Lofrese G; Albanese A; Maria G; Marchese E
Clin Neurol Neurosurg; 2014 Aug; 123():50-4. PubMed ID: 25012011
[TBL] [Abstract][Full Text] [Related]
15. Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery.
Than KD; Baird CJ; Olivi A
Neurosurgery; 2008 Jul; 63(1 Suppl 1):ONS182-6; discussion ONS186-7. PubMed ID: 18728598
[TBL] [Abstract][Full Text] [Related]
16. Use of Tisseel fibrin sealant in neurosurgical procedures: incidence of cerebrospinal fluid leaks and cost-benefit analysis in a retrospective study.
Kassam A; Horowitz M; Carrau R; Snyderman C; Welch W; Hirsch B; Chang YF
Neurosurgery; 2003 May; 52(5):1102-5; discussion 1105. PubMed ID: 12699553
[TBL] [Abstract][Full Text] [Related]
17. Effectiveness of a new gelatin sealant system for dural closure.
Kawai H; Nakagawa I; Nishimura F; Motoyama Y; Park YS; Nakamura M; Nakase H; Suzuki S; Ikada Y
Neurol Res; 2014 Oct; 36(10):866-72. PubMed ID: 24601724
[TBL] [Abstract][Full Text] [Related]
18. Nonsuture dural repair using polyglycolic acid mesh and fibrin glue: clinical application to spinal surgery.
Hida K; Yamaguchi S; Seki T; Yano S; Akino M; Terasaka S; Uchida T; Iwasaki Y
Surg Neurol; 2006 Feb; 65(2):136-42; discussion 142-3. PubMed ID: 16427404
[TBL] [Abstract][Full Text] [Related]
19. Natura abhorret a vacuo--use of fibrin glue as a filler and sealant in neurosurgical "dead spaces". Technical note.
Cappabianca P; Esposito F; Magro F; Cavallo LM; Solari D; Stella L; de Divitiis O
Acta Neurochir (Wien); 2010 May; 152(5):897-904. PubMed ID: 20049488
[TBL] [Abstract][Full Text] [Related]
20. The appearance of dural sealants under MR imaging.
Tarapore PE; Mukherjee P; Mummaneni PV; Ames CP
AJNR Am J Neuroradiol; 2012 Sep; 33(8):1530-3. PubMed ID: 22460340
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]