These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 21095892)

  • 1. Smart hydrogel based microsensing platform for continuous glucose monitoring.
    Tathireddy P; Avula M; Lin G; Cho SH; Guenther M; Schulz V; Gerlach G; Magda JJ; Solzbacher F
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():677-9. PubMed ID: 21095892
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of temperature changes on the performance of ionic strength biosensors based on hydrogels and pressure sensors.
    Avula M; Busche N; Cho SH; Tathireddy P; Rieth LW; Magda JJ; Solzbacher F
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():1855-8. PubMed ID: 22254691
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of glucose levels using a functionalized hydrogel-optical fiber biosensor: toward continuous monitoring of blood glucose in vivo.
    Tierney S; Falch BM; Hjelme DR; Stokke BT
    Anal Chem; 2009 May; 81(9):3630-6. PubMed ID: 19323502
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of a new prototype hydrogel CO( 2 ) sensor; comparison with air tonometry.
    ter Steege RW; Herber S; Olthuis W; Bergveld P; van den Berg A; Kolkman JJ
    J Clin Monit Comput; 2007 Apr; 21(2):83-90. PubMed ID: 17180731
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Study of chemically induced pressure generation of hydrogels under isochoric conditions using a microfabricated device.
    Herber S; Eijkel J; Olthuis W; Bergveld P; van den Berg A
    J Chem Phys; 2004 Aug; 121(6):2746-51. PubMed ID: 15281877
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A miniaturized carbon dioxide gas sensor based on sensing of pH-sensitive hydrogel swelling with a pressure sensor.
    Herber S; Bomer J; Olthuis W; Bergveld P; van den Berg A
    Biomed Microdevices; 2005 Sep; 7(3):197-204. PubMed ID: 16133807
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-term in vivo glucose monitoring using fluorescent hydrogel fibers.
    Heo YJ; Shibata H; Okitsu T; Kawanishi T; Takeuchi S
    Proc Natl Acad Sci U S A; 2011 Aug; 108(33):13399-403. PubMed ID: 21808049
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous fiber-optic sensor for chronic glucose monitoring in vivo.
    Liao KC; Hogen-Esch T; Richmond FJ; Marcu L; Clifton W; Loeb GE
    Biosens Bioelectron; 2008 May; 23(10):1458-65. PubMed ID: 18304798
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-Term
    Liu J; Fang X; Zhang Z; Liu Z; Liu J; Sun K; Yuan Z; Yu J; Chiu DT; Wu C
    Anal Chem; 2022 Feb; 94(4):2195-2203. PubMed ID: 35034435
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Zwitterionic poly(carboxybetaine) hydrogels for glucose biosensors in complex media.
    Yang W; Xue H; Carr LR; Wang J; Jiang S
    Biosens Bioelectron; 2011 Jan; 26(5):2454-9. PubMed ID: 21111598
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of chronically implanted subcutaneous glucose sensors in dogs: the effect of surrounding fluid masses.
    Ward WK; Troupe JE
    ASAIO J; 1999; 45(6):555-61. PubMed ID: 10593686
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration.
    Updike SJ; Shults MC; Gilligan BJ; Rhodes RK
    Diabetes Care; 2000 Feb; 23(2):208-14. PubMed ID: 10868833
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Phase modulation with micromachined resonant mirrors for low-coherence fiber-tip pressure sensors.
    Zhang XM; Liu Y; Bae H; Pang C; Yu M
    Opt Express; 2009 Dec; 17(26):23965-74. PubMed ID: 20052107
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous glucose sensing with fluorescent thin-film hydrogels. 2. Fiber optic sensor fabrication and in vitro testing.
    Thoniyot P; Cappuccio FE; Gamsey S; Cordes DB; Wessling RA; Singaram B
    Diabetes Technol Ther; 2006 Jun; 8(3):279-87. PubMed ID: 16800749
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of subcutaneously implanted glucose sensors: a review.
    Gerritsen M; Jansen JA; Kros A; Nolte RJ; Lutterman JA
    J Invest Surg; 1998; 11(3):163-74. PubMed ID: 9743484
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Construction and calibration of a low-cost bandage pressure monitor.
    Taylor RJ; Taylor AD
    J Wound Care; 1998 Mar; 7(3):125-8. PubMed ID: 9601324
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Miniaturization of an Osmotic Pressure-Based Glucose Sensor for Continuous Intraperitoneal and Subcutaneous Glucose Monitoring by Means of Nanotechnology.
    Pfützner A; Tencer B; Stamm B; Mehta M; Sharma P; Gilyazev R; Jensch H; Thomé N; Huth M
    Sensors (Basel); 2023 May; 23(9):. PubMed ID: 37177745
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Miniature all-glass robust pressure sensor.
    Cibula E; Pevec S; Lenardic B; Pinet E; Donlagic D
    Opt Express; 2009 Mar; 17(7):5098-106. PubMed ID: 19333272
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Glucose Monitoring in Individuals With Diabetes Using a Long-Term Implanted Sensor/Telemetry System and Model.
    Lucisano JY; Routh TL; Lin JT; Gough DA
    IEEE Trans Biomed Eng; 2017 Sep; 64(9):1982-1993. PubMed ID: 27775510
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microcirculation and its relation to continuous subcutaneous glucose sensor accuracy in cardiac surgery patients in the intensive care unit.
    Siegelaar SE; Barwari T; Hermanides J; van der Voort PH; Hoekstra JB; DeVries JH
    J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1283-9. PubMed ID: 23879929
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.