108 related articles for article (PubMed ID: 21095942)
1. Stress development, heat production and dynamic modulus of rat isolated cardiac trabeculae revealed in a flow-through micro-mechano-calorimeter.
Taberner AJ; Han JC; Kirton RS; Loiselle DS; Nielsen PM
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1860-3. PubMed ID: 21095942
[TBL] [Abstract][Full Text] [Related]
2. Energetics of stress production in isolated cardiac trabeculae from the rat.
Han JC; Taberner AJ; Nielsen PM; Kirton RS; Ward ML; Loiselle DS
Am J Physiol Heart Circ Physiol; 2010 Nov; 299(5):H1382-94. PubMed ID: 20729397
[TBL] [Abstract][Full Text] [Related]
3. A work-loop calorimeter for measuring the force-length-heat relationship of working excised cardiac muscle fibers.
Taberner AJ; Han JC; Loiselle DS; Nielsen PM
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():1901-4. PubMed ID: 22254702
[TBL] [Abstract][Full Text] [Related]
4. An innovative work-loop calorimeter for in vitro measurement of the mechanics and energetics of working cardiac trabeculae.
Taberner AJ; Han JC; Loiselle DS; Nielsen PM
J Appl Physiol (1985); 2011 Dec; 111(6):1798-803. PubMed ID: 21903883
[TBL] [Abstract][Full Text] [Related]
5. Do right-ventricular trabeculae gain energetic advantage from having a greater velocity of shortening?
Pham T; Han JC; Taberner A; Loiselle D
J Physiol; 2017 Oct; 595(20):6477-6488. PubMed ID: 28857176
[TBL] [Abstract][Full Text] [Related]
6. Myocardial twitch duration and the dependence of oxygen consumption on pressure-volume area: experiments and modelling.
Han JC; Tran K; Taberner AJ; Nickerson DP; Kirton RS; Nielsen PM; Ward ML; Nash MP; Crampin EJ; Loiselle DS
J Physiol; 2012 Sep; 590(18):4603-22. PubMed ID: 22570375
[TBL] [Abstract][Full Text] [Related]
7. Interventricular comparison of the energetics of contraction of trabeculae carneae isolated from the rat heart.
Han JC; Taberner AJ; Nielsen PM; Loiselle DS
J Physiol; 2013 Feb; 591(3):701-17. PubMed ID: 23184511
[TBL] [Abstract][Full Text] [Related]
8. A unique micromechanocalorimeter for simultaneous measurement of heat rate and force production of cardiac trabeculae carneae.
Han JC; Taberner AJ; Kirton RS; Nielsen PM; Smith NP; Loiselle DS
J Appl Physiol (1985); 2009 Sep; 107(3):946-51. PubMed ID: 19589958
[TBL] [Abstract][Full Text] [Related]
9. Force, sarcomere shortening velocity and ATPase activity.
ter Keurs HE; Deis N; Landesberg A; Nguyen TT; Livshitz L; Stuyvers B; Zhang ML
Adv Exp Med Biol; 2003; 538():583-602; discussion 602. PubMed ID: 15098701
[TBL] [Abstract][Full Text] [Related]
10. Does the intercept of the heat-stress relation provide an accurate estimate of cardiac activation heat?
Pham T; Tran K; Mellor KM; Hickey A; Power A; Ward ML; Taberner A; Han JC; Loiselle D
J Physiol; 2017 Jul; 595(14):4725-4733. PubMed ID: 28455843
[TBL] [Abstract][Full Text] [Related]
11. Heat production in quiescent cardiac muscle is length, velocity and muscle dependent: Implications for active heat measurement.
Garrett AS; Loiselle DS; Han JC; Taberner AJ
Exp Physiol; 2021 Dec; 106(12):2445-2456. PubMed ID: 34605075
[TBL] [Abstract][Full Text] [Related]
12. Pulmonary arterial hypertension reduces energy efficiency of right, but not left, rat ventricular trabeculae.
Pham T; Nisbet L; Taberner A; Loiselle D; Han JC
J Physiol; 2018 Apr; 596(7):1153-1166. PubMed ID: 29363144
[TBL] [Abstract][Full Text] [Related]
13. A high-resolution thermoelectric module-based calorimeter for measuring the energetics of isolated ventricular trabeculae at body temperature.
Johnston CM; Han JC; Ruddy BP; Nielsen PM; Taberner AJ
Am J Physiol Heart Circ Physiol; 2015 Jul; 309(2):H318-24. PubMed ID: 26001412
[TBL] [Abstract][Full Text] [Related]
14. Viscoelastic properties of cross bridges in cardiac muscle.
De Winkel ME; Blangé T; Treijtel BW
Am J Physiol; 1995 Mar; 268(3 Pt 2):H987-98. PubMed ID: 7900896
[TBL] [Abstract][Full Text] [Related]
15. Heat production of quiescent ventricular trabeculae isolated from guinea-pig heart.
Daut J; Elzinga G
J Physiol; 1988 Apr; 398():259-75. PubMed ID: 3392673
[TBL] [Abstract][Full Text] [Related]
16. Cardiac muscle energetics: Improved normalisation of heat using optical coherence tomography.
Cheuk ML; Johnston CM; June-Chiew Han ; Loiselle DS; Nielsen PM; Taberner AJ
Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():2905-2908. PubMed ID: 28268921
[TBL] [Abstract][Full Text] [Related]
17. Cardiac activation heat remains inversely dependent on temperature over the range 27-37°C.
Johnston CM; Han JC; Loiselle DS; Nielsen PM; Taberner AJ
Am J Physiol Heart Circ Physiol; 2016 Jun; 310(11):H1512-9. PubMed ID: 27016583
[TBL] [Abstract][Full Text] [Related]
18. Description of a direct-indirect room-sized calorimeter.
Seale JL; Rumpler WV; Moe PW
Am J Physiol; 1991 Feb; 260(2 Pt 1):E306-20. PubMed ID: 1996633
[TBL] [Abstract][Full Text] [Related]
19. Measuring the mechanical efficiency of a working cardiac muscle sample at body temperature using a flow-through calorimeter.
Taberner AJ; Johnston CM; Pham T; June-Chiew Han ; Ruddy BP; Loiselle DS; Nielsen PM
Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():7966-9. PubMed ID: 26738140
[TBL] [Abstract][Full Text] [Related]
20. Force generation and work production by covalently cross-linked actin-myosin cross-bridges in rabbit muscle fibers.
Bershitsky SY; Tsaturyan AK
Biophys J; 1995 Sep; 69(3):1011-21. PubMed ID: 8519956
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]