These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 21096207)

  • 61. Excel Methods to Design and Validate in Microelectronics (Complementary Metal-Oxide-Semiconductor, CMOS) for Biomedical Instrumentation Application.
    Dieck-Assad G; Rodríguez-Delgado JM; González Peña OI
    Sensors (Basel); 2021 Nov; 21(22):. PubMed ID: 34833561
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Detection of structured single-strand DNA via solid-state nanopore.
    Liu SC; Li Q; Ying YL; Long YT
    Electrophoresis; 2019 Aug; 40(16-17):2112-2116. PubMed ID: 30912583
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Very low-noise ENG amplifier system using CMOS technology.
    Rieger R; Schuettler M; Pal D; Clarke C; Langlois P; Taylor J; Donaldson N
    IEEE Trans Neural Syst Rehabil Eng; 2006 Dec; 14(4):427-37. PubMed ID: 17190035
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Monitoring of an ATP-binding aptamer and its conformational changes using an α-hemolysin nanopore.
    Ying YL; Wang HY; Sutherland TC; Long YT
    Small; 2011 Jan; 7(1):87-94. PubMed ID: 21086519
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Technical note. A design study of a bioelectric amplifier and improvement of its parameters.
    Amer MB
    J Med Eng Technol; 1999; 23(1):15-9. PubMed ID: 10202698
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Nanopore unstacking of single-stranded DNA helices.
    Chen P; Li CM
    Small; 2007 Jul; 3(7):1204-8. PubMed ID: 17520590
    [No Abstract]   [Full Text] [Related]  

  • 67. Resistive-pulse detection of short dsDNAs using a chemically functionalized conical nanopore sensor.
    Kececi K; Sexton LT; Buyukserin F; Martin CR
    Nanomedicine (Lond); 2008 Dec; 3(6):787-96. PubMed ID: 19025453
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Nanopore Logic Operation with DNA to RNA Transcription in a Droplet System.
    Ohara M; Takinoue M; Kawano R
    ACS Synth Biol; 2017 Jul; 6(7):1427-1432. PubMed ID: 28414903
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Patch-clamp amplifiers on a chip.
    Weerakoon P; Culurciello E; Yang Y; Santos-Sacchi J; Kindlmann PJ; Sigworth FJ
    J Neurosci Methods; 2010 Oct; 192(2):187-92. PubMed ID: 20637803
    [TBL] [Abstract][Full Text] [Related]  

  • 70. High-quality recording of bioelectric events. Part 2. Low-noise, low-power multichannel amplifier design.
    Metting van Rijn AC; Peper A; Grimbergen CA
    Med Biol Eng Comput; 1991 Jul; 29(4):433-40. PubMed ID: 1787761
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Noise analysis and performance comparison of low current measurement systems for biomedical applications.
    Dongsoo Kim ; Goldstein B; Wei Tang ; Sigworth FJ; Culurciello E
    IEEE Trans Biomed Circuits Syst; 2013 Feb; 7(1):52-62. PubMed ID: 23853279
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Enhanced ICMR amplifier for high CMRR biopotential recordings.
    Oreggioni J; Castro-Lisboa P; Silveira F
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():3746-3749. PubMed ID: 31946689
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Miniaturized planar lipid bilayer: increased stability, low electric noise and fast fluid perfusion.
    Mach T; Chimerel C; Fritz J; Fertig N; Winterhalter M; Fütterer C
    Anal Bioanal Chem; 2008 Feb; 390(3):841-6. PubMed ID: 17972068
    [TBL] [Abstract][Full Text] [Related]  

  • 74. A Low-Noise Transimpedance Amplifier for BLM-Based Ion Channel Recording.
    Crescentini M; Bennati M; Saha SC; Ivica J; de Planque M; Morgan H; Tartagni M
    Sensors (Basel); 2016 May; 16(5):. PubMed ID: 27213382
    [TBL] [Abstract][Full Text] [Related]  

  • 75. [Leak subtraction analysis of Axon patch clamp system].
    Liu ZW; Li LJ; Liu CG
    Zhongguo Ying Yong Sheng Li Xue Za Zhi; 2003 Feb; 19(1):98-101. PubMed ID: 21207870
    [TBL] [Abstract][Full Text] [Related]  

  • 76. MOSAIC: A Modular Single-Molecule Analysis Interface for Decoding Multistate Nanopore Data.
    Forstater JH; Briggs K; Robertson JW; Ettedgui J; Marie-Rose O; Vaz C; Kasianowicz JJ; Tabard-Cossa V; Balijepalli A
    Anal Chem; 2016 Dec; 88(23):11900-11907. PubMed ID: 27797501
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Replication of individual DNA molecules under electronic control using a protein nanopore.
    Olasagasti F; Lieberman KR; Benner S; Cherf GM; Dahl JM; Deamer DW; Akeson M
    Nat Nanotechnol; 2010 Nov; 5(11):798-806. PubMed ID: 20871614
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Low-Area Four-Channel Controlled Dielectric Breakdown System Design for Point-of-Care Applications.
    Hong J; Oh Y; Choi H; Kim J
    Sensors (Basel); 2022 Feb; 22(5):. PubMed ID: 35271042
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Noise and linearity optimization methods for a 1.9GHz low noise amplifier.
    Guo W; Huang DQ
    J Zhejiang Univ Sci; 2003; 4(3):281-6. PubMed ID: 12765280
    [TBL] [Abstract][Full Text] [Related]  

  • 80. A neural amplifier with high programmable gain and tunable bandwidth.
    Perlin GE; Sodagar AM; Wise KD
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():3154-7. PubMed ID: 19163376
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.