270 related articles for article (PubMed ID: 21096549)
1. Bandwidth tunable amplifier for recording biopotential signals.
Hwang S; Aninakwa K; Sonkusale S
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():662-5. PubMed ID: 21096549
[TBL] [Abstract][Full Text] [Related]
2. A Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor.
Tzu-Yun Wang ; Min-Rui Lai ; Twigg CM; Sheng-Yu Peng
IEEE Trans Biomed Circuits Syst; 2014 Jun; 8(3):411-22. PubMed ID: 24108476
[TBL] [Abstract][Full Text] [Related]
3. A band-tunable, multichannel amplifier for neural recording with AP/LFP separation and dual-threshold adaptive AP detector.
Wu JY; Tang KT
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():1847-50. PubMed ID: 22254689
[TBL] [Abstract][Full Text] [Related]
4. A low-power self-biased neural amplifier for implantable EEG recording system ICs.
Kim J; Pedrotti K
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1573-6. PubMed ID: 21096384
[TBL] [Abstract][Full Text] [Related]
5. A Compact Sub-μW CMOS ECG Amplifier With 57.5-MΩ Z
Sawigun C; Thanapitak S
IEEE Trans Biomed Circuits Syst; 2021 Jun; 15(3):549-558. PubMed ID: 34081584
[TBL] [Abstract][Full Text] [Related]
6. Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays.
Olsson RH; Buhl DL; Sirota AM; Buzsaki G; Wise KD
IEEE Trans Biomed Eng; 2005 Jul; 52(7):1303-11. PubMed ID: 16041994
[TBL] [Abstract][Full Text] [Related]
7. A Low-power and Low-noise Multi-purpose Chopper Amplifier with High CMRR and PSRR.
Shad E; Molinas M; Ytterdal T
Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():3998-4001. PubMed ID: 33018876
[TBL] [Abstract][Full Text] [Related]
8. The design of CMOS general-purpose analog front-end circuit with tunable gain and bandwidth for biopotential signal recording systems.
Chen WM; Yang WC; Tsai TY; Chiueh H; Wu CY
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():4784-7. PubMed ID: 22255408
[TBL] [Abstract][Full Text] [Related]
9. Design and measurements of 64-channel ASIC for neural signal recording.
Kmon P; Zoladz M; Grybos P; Szczygiel R
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():528-31. PubMed ID: 19964226
[TBL] [Abstract][Full Text] [Related]
10. Meet the challenge of high-pass filter and ST-segment requirements with a DC-coupled digital electrocardiogram amplifier.
Abächerli R; Schmid HJ
J Electrocardiol; 2009; 42(6):574-9. PubMed ID: 19700169
[TBL] [Abstract][Full Text] [Related]
11. A fully integrated neural recording amplifier with DC input stabilization.
Mohseni P; Najafi K
IEEE Trans Biomed Eng; 2004 May; 51(5):832-7. PubMed ID: 15132510
[TBL] [Abstract][Full Text] [Related]
12. Current-Efficient Preamplifier Architecture for CMRR Sensitive Neural Recording Applications.
Oreggioni J; Caputi AA; Silveira F
IEEE Trans Biomed Circuits Syst; 2018 Jun; 12(3):689-699. PubMed ID: 29877831
[TBL] [Abstract][Full Text] [Related]
13. Programmable ExG biopotential front-end IC for wearable applications.
Teng SL; Rieger R; Lin YB
IEEE Trans Biomed Circuits Syst; 2014 Aug; 8(4):543-51. PubMed ID: 25073129
[TBL] [Abstract][Full Text] [Related]
14. Flexible implementation of front-end bioelectric signal amplifier using FPAA for telemedicine system.
Chan UF; Chan WW; Pun SH; Vai MI; Mak PU
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3721-4. PubMed ID: 18002806
[TBL] [Abstract][Full Text] [Related]
15. A 2.64- μW 71-dB SNDR Discrete-Time Signal-Folding Amplifier for Reducing ADC's Resolution Requirement in Wearable ECG Acquisition Systems.
Ratametha C; Tepwimonpetkun S; Wattanapanitch W
IEEE Trans Biomed Circuits Syst; 2020 Feb; 14(1):48-64. PubMed ID: 31796416
[TBL] [Abstract][Full Text] [Related]
16. A low power, low noise Programmable Analog Front End (PAFE) for biopotential measurements.
Adimulam MK; Divya A; Tejaswi K; Srinivas MB
Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():3844-3847. PubMed ID: 29060736
[TBL] [Abstract][Full Text] [Related]
17. Fully Integrated Biopotential Acquisition Analog Front-End IC.
Song H; Park Y; Kim H; Ko H
Sensors (Basel); 2015 Sep; 15(10):25139-56. PubMed ID: 26437404
[TBL] [Abstract][Full Text] [Related]
18. A Micropower Chopper CBIA Using DSL-Embedded Input Stage With 0.4 V EO Tolerance for Dry-Electrode Biopotential Recording.
Thanapitak S; Surakampontorn W; Sawigun C
IEEE Trans Biomed Circuits Syst; 2023 Jun; 17(3):458-469. PubMed ID: 37023150
[TBL] [Abstract][Full Text] [Related]
19. A CMOS power-efficient low-noise current-mode front-end amplifier for neural signal recording.
Wu CY; Chen WM; Kuo LT
IEEE Trans Biomed Circuits Syst; 2013 Apr; 7(2):107-14. PubMed ID: 23853293
[TBL] [Abstract][Full Text] [Related]
20. Power-to-Noise Optimization in the Design of Neural Recording Amplifier Based on Current Scaling, Source Degeneration Resistor, and Current Reuse.
Wang Z; Wang X; Shu G; Yin M; Huang S; Yin M
Biosensors (Basel); 2024 Feb; 14(2):. PubMed ID: 38392030
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]