These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 21097298)

  • 21. A new approach in the BCI research based on fractal dimension as feature and Adaboost as classifier.
    Boostani R; Moradi MH
    J Neural Eng; 2004 Dec; 1(4):212-7. PubMed ID: 15876641
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Measuring complexity in different muscles during sustained contraction using fractal properties of SEMG signal.
    Arjunan SP; Kumar DK
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():5656-5659. PubMed ID: 30441619
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A novel fuzzy approach for automatic Brunnstrom stage classification using surface electromyography.
    Liparulo L; Zhang Z; Panella M; Gu X; Fang Q
    Med Biol Eng Comput; 2017 Aug; 55(8):1367-1378. PubMed ID: 27909939
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fatigue estimation using a novel multi-fractal detrended fluctuation analysis-based approach.
    Talebinejad M; Chan AD; Miri A
    J Electromyogr Kinesiol; 2010 Jun; 20(3):433-9. PubMed ID: 19589697
    [TBL] [Abstract][Full Text] [Related]  

  • 25. EMG feature assessment for myoelectric pattern recognition and channel selection: a study with incomplete spinal cord injury.
    Liu J; Li X; Li G; Zhou P
    Med Eng Phys; 2014 Jul; 36(7):975-80. PubMed ID: 24844608
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Surface electromyography based muscle fatigue detection using high-resolution time-frequency methods and machine learning algorithms.
    Karthick PA; Ghosh DM; Ramakrishnan S
    Comput Methods Programs Biomed; 2018 Feb; 154():45-56. PubMed ID: 29249346
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Development of the hand motion recognition system based on surface EMG using suitable measurement channels for pattern recognition.
    Nagata K; Ando K; Magatani K; Yamada M
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5214-7. PubMed ID: 18003183
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Pattern recognition of surface electromyography signal based on multi-scale fuzzy entropy].
    Zou X; Lei M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2012 Dec; 29(6):1184-8. PubMed ID: 23469553
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Movement error rate for evaluation of machine learning methods for sEMG-based hand movement classification.
    Gijsberts A; Atzori M; Castellini C; Muller H; Caputo B
    IEEE Trans Neural Syst Rehabil Eng; 2014 Jul; 22(4):735-44. PubMed ID: 24760932
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A two-dimensional matrix image based feature extraction method for classification of sEMG: A comparative analysis based on SVM, KNN and RBF-NN.
    Wen T; Zhang Z; Qiu M; Zeng M; Luo W
    J Xray Sci Technol; 2017; 25(2):287-300. PubMed ID: 28269818
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Selection of suitable hand gestures for reliable myoelectric human computer interface.
    Castro MC; Arjunan SP; Kumar DK
    Biomed Eng Online; 2015 Apr; 14():30. PubMed ID: 25889735
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Extracting and Classifying Spatial Muscle Activation Patterns in Forearm Flexor Muscles Using High-Density Electromyogram Recordings.
    Dai C; Hu X
    Int J Neural Syst; 2019 Feb; 29(1):1850025. PubMed ID: 29954235
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Wavelet analysis for Support Vector Machine classification of motor unit action potentials.
    Dobrowolski AP; Wierzbowski M; Tomczykiewicz K
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():4632-5. PubMed ID: 21096234
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Multi-receiver precision decomposition of intramuscular EMG signals.
    Nawab SH; Wotiz RP; De Luca CJ
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1252-5. PubMed ID: 17945629
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Addressing source separation and identification issues in surface EMG using blind source separation.
    Naik GR; Kumar DK; Palaniswami M
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():1124-7. PubMed ID: 19162861
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Surface electromyography signal processing and classification techniques.
    Chowdhury RH; Reaz MB; Ali MA; Bakar AA; Chellappan K; Chang TG
    Sensors (Basel); 2013 Sep; 13(9):12431-66. PubMed ID: 24048337
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Surface EMG pattern recognition for real-time control of a wrist exoskeleton.
    Khokhar ZO; Xiao ZG; Menon C
    Biomed Eng Online; 2010 Aug; 9():41. PubMed ID: 20796304
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Intrinsic mode entropy: an enhanced classification means for automated Greek Sign Language gesture recognition.
    Kosmidou VE; Hadjileontiadis LJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5057-60. PubMed ID: 19163853
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Nonnegative matrix factorization for the identification of EMG finger movements: evaluation using matrix analysis.
    Naik GR; Nguyen HT
    IEEE J Biomed Health Inform; 2015 Mar; 19(2):478-485. PubMed ID: 25486650
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Correlation analysis of electromyogram signals for multiuser myoelectric interfaces.
    Khushaba RN
    IEEE Trans Neural Syst Rehabil Eng; 2014 Jul; 22(4):745-55. PubMed ID: 24760933
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.