These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 21097407)

  • 1. [Three-dimensional finite element analysis of biomechanical characteristics of cancellous screw in different bone densities].
    Tian C; Zhang MC; Ouyang J
    Nan Fang Yi Ke Da Xue Xue Bao; 2010 Nov; 30(11):2466-8. PubMed ID: 21097407
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigation of fixation screw pull-out strength on human spine.
    Zhang QH; Tan SH; Chou SM
    J Biomech; 2004 Apr; 37(4):479-85. PubMed ID: 14996559
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical analysis of pedicle screw placement: a feasibility study.
    Wagnac E; Michardière D; Garo A; Arnoux PJ; Mac-Thiong JM; Aubin CE
    Stud Health Technol Inform; 2010; 158():167-71. PubMed ID: 20543418
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis.
    Kong L; Hu K; Li D; Song Y; Yang J; Wu Z; Liu B
    Int J Oral Maxillofac Implants; 2008; 23(1):65-74. PubMed ID: 18416414
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite element analysis of miniscrew implants used for orthodontic anchorage.
    Liu TC; Chang CH; Wong TY; Liu JK
    Am J Orthod Dentofacial Orthop; 2012 Apr; 141(4):468-76. PubMed ID: 22464529
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of bone materials on the screw pull-out strength in human spine.
    Zhang QH; Tan SH; Chou SM
    Med Eng Phys; 2006 Oct; 28(8):795-801. PubMed ID: 16414303
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of parallel and diverging screw angles in the stability of locked plate constructs.
    Wähnert D; Windolf M; Brianza S; Rothstock S; Radtke R; Brighenti V; Schwieger K
    J Bone Joint Surg Br; 2011 Sep; 93(9):1259-64. PubMed ID: 21911539
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical tests and finite element models for bone holding power of tibial locking screws.
    Hou SM; Hsu CC; Wang JL; Chao CK; Lin J
    Clin Biomech (Bristol, Avon); 2004 Aug; 19(7):738-45. PubMed ID: 15288461
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical evaluation of magnesium-based resorbable metallic screw system in a bilateral sagittal split ramus osteotomy model using three-dimensional finite element analysis.
    Lee JY; Lee JW; Pang KM; Kim HE; Kim SM; Lee JH
    J Oral Maxillofac Surg; 2014 Feb; 72(2):402.e1-13. PubMed ID: 24280169
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.
    Tada S; Stegaroiu R; Kitamura E; Miyakawa O; Kusakari H
    Int J Oral Maxillofac Implants; 2003; 18(3):357-68. PubMed ID: 12814310
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical effects of insertion location and bone cement augmentation on the anchoring strength of iliac screw.
    Yu BS; Li ZM; Zhou ZY; Zeng LW; Wang LB; Zheng ZM; Lu WW
    Clin Biomech (Bristol, Avon); 2011 Jul; 26(6):556-61. PubMed ID: 21345556
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis.
    Zdero R; Olsen M; Bougherara H; Schemitsch EH
    Proc Inst Mech Eng H; 2008 Nov; 222(8):1175-83. PubMed ID: 19143412
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Three-dimensional finite element investigation of lateral mass screw fixation and transarticular screw fixation in lower cervical spine].
    Duan Y; Jin A; Zhang H; Min S; Hu K
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 Dec; 24(12):1494-9. PubMed ID: 21261101
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Proximal half angle of the screw thread is a critical design variable affecting the pull-out strength of cancellous bone screws.
    Wang Y; Mori R; Ozoe N; Nakai T; Uchio Y
    Clin Biomech (Bristol, Avon); 2009 Nov; 24(9):781-5. PubMed ID: 19699567
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Selection of the distraction implant length with improved biomechanical properties by three-dimensional finite element analysis.
    Gao J; Li T; Hou XC; Wang Z; Kong L; Chen JH
    J Oral Rehabil; 2011 Apr; 38(4):270-7. PubMed ID: 20819137
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Screw pull-out force is dependent on screw orientation in an anterior cervical plate construct.
    DiPaola CP; Jacobson JA; Awad H; Conrad BP; Rechtine GR
    J Spinal Disord Tech; 2007 Jul; 20(5):369-73. PubMed ID: 17607102
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
    Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
    J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems: finite element analysis.
    Qian L; Todo M; Matsushita Y; Koyano K
    Int J Oral Maxillofac Implants; 2009; 24(5):877-86. PubMed ID: 19865628
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anatomical and Biomechanical Stability of Single/Double Screw-Cancellous Bone Fixations of Regan-Morry Type III Ulnar Coronoid Fractures in Adults: CT Measurement and Finite Element Analysis.
    Ye H; Yang Y; Xing T; Tan G; Jin S; Zhao Z; Zhang W; Li Y; Zhang L; Wang J; Zheng R; Lu Y; Wu L
    Orthop Surg; 2023 Apr; 15(4):1072-1084. PubMed ID: 36647280
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Which is the preferred revision technique for loosened iliac screw? A novel technique of boring cement injection from the outer cortical shell.
    Yu BS; Yang ZK; Li ZM; Zeng LW; Wang LB; Lu WW
    J Spinal Disord Tech; 2011 Aug; 24(6):E49-56. PubMed ID: 21685804
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.