4. Investigation of image lag and modulation transfer function in fluoroscopy images obtained with a dynamic flat-panel detector. Kawashima H; Tanaka R; Ichikawa K; Matsubara K; Iida H; Sanada S Radiol Phys Technol; 2013 Jul; 6(2):367-74. PubMed ID: 23568338 [TBL] [Abstract][Full Text] [Related]
5. [Effect on image data resampling in evaluation of the basic imaging properties for a digital radiographic system based on a flat panel detector]. Katayama R; Sakai S; Morishita J; Sakaguchi T; Ohkubo S; Maeda T; Takada K; Hayabuchi N Nihon Hoshasen Gijutsu Gakkai Zasshi; 2007 Jul; 63(7):749-56. PubMed ID: 17917336 [TBL] [Abstract][Full Text] [Related]
6. Experimental comparison of flat-panel detector performance for direct and indirect systems. Gomi T; Miyagawa J; Hirano H Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 Dec; 61(12):1675-80. PubMed ID: 16395244 [TBL] [Abstract][Full Text] [Related]
7. [Comparison of basic imaging properties for digital radiographic systems based on a direct conversion type of flat panel detector]. Sakai S; Katayama R; Morishita J; Sakaguchi T; Ohkubo S; Maeda T; Hayabuchi N Nihon Hoshasen Gijutsu Gakkai Zasshi; 2008 Jan; 64(1):41-9. PubMed ID: 18311020 [TBL] [Abstract][Full Text] [Related]
8. An experimental comparison of detector performance for direct and indirect digital radiography systems. Samei E; Flynn MJ Med Phys; 2003 Apr; 30(4):608-22. PubMed ID: 12722813 [TBL] [Abstract][Full Text] [Related]
10. [Investigation of image quality identification utilizing physical image quality measurement in direct- and indirect-type of flat panel detectors and computed radiography]. Yokoi T; Takata T; Ichikawa K Nihon Hoshasen Gijutsu Gakkai Zasshi; 2011; 67(11):1415-25. PubMed ID: 22104233 [TBL] [Abstract][Full Text] [Related]
11. An experimental comparison of flat-panel detector performance for direct and indirect systems (initial experiences and physical evaluation). Gomi T; Koshida K; Miyati T; Miyagawa J; Hirano H J Digit Imaging; 2006 Dec; 19(4):362-70. PubMed ID: 16763929 [TBL] [Abstract][Full Text] [Related]
12. Image quality in two phosphor-based flat panel digital radiographic detectors. Samei E Med Phys; 2003 Jul; 30(7):1747-57. PubMed ID: 12906192 [TBL] [Abstract][Full Text] [Related]
13. [Physical imaging properties of a flat panel X-ray detector system]. Yoshida A; Nakamura S; Nishihara S; Kohama C; Takahata A; Fujikawa K Igaku Butsuri; 2002; 22(4):246-54. PubMed ID: 12766270 [TBL] [Abstract][Full Text] [Related]
14. Is the image quality of conventional chest radiography obtained from a two-layer flat panel detector affected by the internal structure of the detector? Takarabe S; Kuramoto T; Shibayama Y; Yamasaki Y; Kitamura Y; Yoshikawa H; Kato T Phys Med; 2022 Mar; 95():176-181. PubMed ID: 35219067 [TBL] [Abstract][Full Text] [Related]
15. Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Floyd CE; Warp RJ; Dobbins JT; Chotas HG; Baydush AH; Vargas-Voracek R; Ravin CE Radiology; 2001 Mar; 218(3):683-8. PubMed ID: 11230640 [TBL] [Abstract][Full Text] [Related]
16. On site evaluation of three flat panel detectors for digital radiography. Borasi G; Nitrosi A; Ferrari P; Tassoni D Med Phys; 2003 Jul; 30(7):1719-31. PubMed ID: 12906189 [TBL] [Abstract][Full Text] [Related]
17. Application of a variable filter for presampled modulation transfer function analysis with the edge method. Higashide R; Ichikawa K; Kunitomo H; Ohashi K Radiol Phys Technol; 2015 Jul; 8(2):320-30. PubMed ID: 26088943 [TBL] [Abstract][Full Text] [Related]
18. Physical imaging properties and low-contrast performance of a newly developed flat-panel digital radiographic system. Matsumoto M; Yamazaki T; Nokita M; Hayashida S; Yoshida A; Ideguchi T; Himuro K; Ohki M; Kumazawa S; Higashida Y Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 Dec; 61(12):1656-65. PubMed ID: 16395242 [TBL] [Abstract][Full Text] [Related]
19. Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system. Tanaka N; Yano Y; Yabuuchi H; Akasaka T; Sasaki M; Ohki M; Morishita J Radiol Phys Technol; 2013 Jan; 6(1):162-9. PubMed ID: 23143711 [TBL] [Abstract][Full Text] [Related]
20. A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response. Kuhls-Gilcrist A; Bednarek DR; Rudin S Proc SPIE Int Soc Opt Eng; 2010 Mar; 7622(76224W):76224W-76244W9. PubMed ID: 21170177 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]