These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 21107217)

  • 1. Exposure of distal radius fractures using a direct radial approach with mobilization of the superficial branch of the radial nerve.
    Pirela-Cruz MA; Scher DL
    Tech Hand Up Extrem Surg; 2010 Dec; 14(4):218-21. PubMed ID: 21107217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Percutaneous pinning of distal radius fractures: an anatomic study demonstrating the proximity of K-wires to structures at risk.
    Chia B; Catalano LW; Glickel SZ; Barron OA; Meier K
    J Hand Surg Am; 2009; 34(6):1014-20. PubMed ID: 19643288
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dorsal double-plate fixation of the distal radius.
    Rikli DA; Businger A; Babst R
    Oper Orthop Traumatol; 2005 Dec; 17(6):624-40. PubMed ID: 16369757
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Exposure of the forearm and distal radius.
    Klausmeyer MA; Mudgal C
    Hand Clin; 2014 Nov; 30(4):427-33, v. PubMed ID: 25440071
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Applied anatomy of the superficial branch of the radial nerve.
    Robson AJ; See MS; Ellis H
    Clin Anat; 2008 Jan; 21(1):38-45. PubMed ID: 18092362
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Superficial radial nerve damage due to Kirschner wiring of the radius.
    Singh S; Trikha P; Twyman R
    Injury; 2005 Feb; 36(2):330-2. PubMed ID: 15664599
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
    Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
    J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intramedullary fixation of distal radius fractures.
    Ilyas AM
    J Hand Surg Am; 2009 Feb; 34(2):341-6. PubMed ID: 19181236
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safety of the limited open technique of bone-transfixing threaded-pin placement for external fixation of distal radial fractures: a cadaver study.
    Hassan DM; Johnston GH
    Can J Surg; 1999 Oct; 42(5):363-5. PubMed ID: 10526521
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliable techniques to avoid damaging the superficial radial nerve due to percutaneous Kirschner wire fixation of the distal radius fracture through the radial styloid process.
    Chen Y; Zheng X; Wang J; Zhu Y; Zhan C
    Surg Radiol Anat; 2010 Oct; 32(8):711-7. PubMed ID: 20306262
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Anatomy of the posterior interosseous nerve in relation to fixation of the radial head.
    Tornetta P; Hochwald N; Bono C; Grossman M
    Clin Orthop Relat Res; 1997 Dec; (345):215-8. PubMed ID: 9418643
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anatomic course of the superficial branch of the radial nerve in the wrist and its location in relation to wrist arthroscopy portals: a cadaveric study.
    Kiliç A; Kale A; Usta A; Bilgili F; Kabukçuoğlu Y; Sökücü S
    Arthroscopy; 2009 Nov; 25(11):1261-4. PubMed ID: 19896048
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of 2 surgical approaches for volar locking plate osteosynthesis of the distal radius.
    Lattmann T; Dietrich M; Meier C; Kilgus M; Platz A
    J Hand Surg Am; 2008 Sep; 33(7):1135-43. PubMed ID: 18762110
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relation of Lateral Antebrachial Cutaneous Nerve to the Volar Approach to Distal Radius.
    Tan VH; Tong PY; Liao J; Lee HJ; Foo TL
    J Hand Surg Asian Pac Vol; 2016 Feb; 21(1):68-71. PubMed ID: 27454506
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach.
    Sen MK; Strauss N; Harvey EJ
    Tech Hand Up Extrem Surg; 2008 Mar; 12(1):2-6. PubMed ID: 18388748
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the safe zone for percutaneous Kirschner-wire placement in the distal radius: Cadaveric study.
    Korcek L; Wongworawat M
    Clin Anat; 2011 Nov; 24(8):1005-9. PubMed ID: 21547957
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The relationship of the superficial radial nerve and its branch to the thumb to the first extensor compartment.
    Gurses IA; Coskun O; Gayretli O; Kale A; Ozturk A
    J Hand Surg Am; 2014 Mar; 39(3):480-3. PubMed ID: 24495622
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Single-incision extensile volar approach to the distal radius and concurrent carpal tunnel release: cadaveric study.
    Pensy RA; Brunton LM; Parks BG; Higgins JP; Chhabra AB
    J Hand Surg Am; 2010 Feb; 35(2):217-22. PubMed ID: 20141892
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Corrective osteotomy of malunited distal radius fractures].
    Oestern HJ; Laqué K
    Orthopade; 1990 Nov; 19(6):343-9. PubMed ID: 2277707
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Corrective osteotomy using Hoffmann II external fixators for extra-auricular malunion of the distal radius].
    Baillon R; Gris M; Tollet P; Schuind F; Burny F
    Acta Orthop Belg; 2001 Dec; 67(5):500-4. PubMed ID: 11822081
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.