These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 2110802)

  • 1. Transcutaneous carbon dioxide monitoring.
    Rennie JM
    Arch Dis Child; 1990 Apr; 65(4 Spec No):345-6. PubMed ID: 2110802
    [No Abstract]   [Full Text] [Related]  

  • 2. What's the latest on carbon dioxide monitoring?
    Thomas PE
    Neonatal Netw; 2004; 23(4):70-2. PubMed ID: 15317386
    [No Abstract]   [Full Text] [Related]  

  • 3. Discrepancies between transcutaneous and end-tidal carbon dioxide monitoring in the critically ill neonate with respiratory distress syndrome.
    Luz G; Haisjackl M; Hasibeder W; Altenberger H
    Crit Care Med; 1990 Sep; 18(9):1050. PubMed ID: 2118442
    [No Abstract]   [Full Text] [Related]  

  • 4. Effect of tilting on oxygenation in newborn infants.
    Thoresen M; Cowan F; Whitelaw A
    Arch Dis Child; 1988 Mar; 63(3):315-7. PubMed ID: 3128187
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Current correction factors inadequately predict the relationship between transcutaneous (tc) and arterial PCO2 in sick neonates.
    Martin RJ; Beoglos A; Miller MJ; DiFiore JM; Carlo WA
    Adv Exp Med Biol; 1987; 220():51-3. PubMed ID: 3118655
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Transcutaneous monitoring of blood gas (author's transl)].
    Willard D; Messer J; Erny P; Eberhard P
    Ann Pediatr (Paris); 1981 Dec; 28(10):715-9. PubMed ID: 6798914
    [No Abstract]   [Full Text] [Related]  

  • 7. Agreement of carbon dioxide levels measured by arterial, transcutaneous and end tidal methods in preterm infants < or = 28 weeks gestation.
    Aliwalas LL; Noble L; Nesbitt K; Fallah S; Shah V; Shah PS
    J Perinatol; 2005 Jan; 25(1):26-9. PubMed ID: 15496874
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Combined transcutaneous oxygen, carbon dioxide tensions and end-expired CO2 levels in severely ill newborns.
    Geven WB; Nagler E; de Boo T; Lemmens W
    Adv Exp Med Biol; 1987; 220():115-20. PubMed ID: 3118653
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effects of body position on transcutaneous oxygen tension.
    Hader CF; Sorensen ER
    Pediatr Nurs; 1988; 14(6):469-73. PubMed ID: 3211604
    [No Abstract]   [Full Text] [Related]  

  • 10. Transcutaneous carbon dioxide for short-term monitoring of neonates.
    Kost GJ; Chow JL; Kenny MA
    Clin Chem; 1983 Aug; 29(8):1534-6. PubMed ID: 6409451
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transcutaneous PO2 and PCO2 during surfactant therapy in newborn infants with idiopathic respiratory distress syndrome.
    Oetomo SB; Robertson B; Okken A
    Adv Exp Med Biol; 1987; 220():121-2. PubMed ID: 3673752
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcutaneous carbon dioxide monitoring during neonatal transport.
    Jacob J; Rose D; Stilson M; Davis RF; Gilbert D
    Crit Care Med; 1986 Dec; 14(12):1050-2. PubMed ID: 3780248
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Arterialisation of transcutaneous oxygen and carbon dioxide.
    Broadhurst E; Helms P; Vyas H; Cheriyan G
    Arch Dis Child; 1988 Nov; 63(11):1395-6. PubMed ID: 3144247
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Prevention of iatrogenic effects of artificial ventilation with transcutaneous monitoring of PO2 and PCO2 in the newborn infant].
    Erny P; Alt R; Messer J; Willard D
    Pediatrie; 1983; 38(3):161-72. PubMed ID: 6431393
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-invasive monitoring of carbon-dioxide in newborns and children.
    Dutta S
    Indian J Pediatr; 1999; 66(1):131-6. PubMed ID: 10798045
    [No Abstract]   [Full Text] [Related]  

  • 16. [Transcutaneous partial pressure measurement].
    Huch R
    Biomed Tech (Berl); 1990; 35 Suppl 1():24-6. PubMed ID: 2112963
    [No Abstract]   [Full Text] [Related]  

  • 17. [Artificial respiration of newborn infants. Definition, monitoring and possibilities for errors].
    Obladen M
    Monatsschr Kinderheilkd; 1984 Jun; 132(6):381-4. PubMed ID: 6433179
    [No Abstract]   [Full Text] [Related]  

  • 18. [Initial experiences with transcutaneous pCO2 measurement in newborn infants with cardiopulmonary adaptation disorders].
    Kurt E; Schwarze R
    Kinderarztl Prax; 1985 Jan; 53(1):15-9. PubMed ID: 3920430
    [No Abstract]   [Full Text] [Related]  

  • 19. [Simultaneous measurements of end-expiratory and transcutaneous carbon dioxide partial pressure in ventilated premature and newborn infants].
    Arsowa S; Schmalisch G; Wauer RR
    Klin Padiatr; 1997; 209(2):47-53. PubMed ID: 9198671
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcutaneous Carbon Dioxide Monitoring in Subjects With Acute Respiratory Failure and Severe Hypercapnia.
    Ruiz Y; Farrero E; Córdoba A; González N; Dorca J; Prats E
    Respir Care; 2016 Apr; 61(4):428-33. PubMed ID: 26786741
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.