BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 21110259)

  • 1. An indentation apparatus for evaluating discomfort and pain thresholds in conjunction with mechanical properties of foot tissue in vivo.
    Xiong S; Goonetilleke RS; Witana CP; Rodrigo WD
    J Rehabil Res Dev; 2010; 47(7):629-41. PubMed ID: 21110259
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy and reliability testing of a portable soft tissue indentor.
    Klaesner JW; Commean PK; Hastings MK; Zou D; Mueller MJ
    IEEE Trans Neural Syst Rehabil Eng; 2001 Jun; 9(2):232-40. PubMed ID: 11474976
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pressure thresholds of the human foot: measurement reliability and effects of stimulus characteristics.
    Xiong S; Goonetilleke RS; Jiang Z
    Ergonomics; 2011 Mar; 54(3):282-93. PubMed ID: 21390958
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Extraction of mechanical properties of foot plantar tissues using ultrasound indentation associated with genetic algorithm.
    Ling HY; Choi PC; Zheng YP; Lau KT
    J Mater Sci Mater Med; 2007 Aug; 18(8):1579-86. PubMed ID: 17483905
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A hand-held probe for vibro-elastography.
    Rivaz H; Rohling R
    Med Image Comput Comput Assist Interv; 2005; 8(Pt 1):613-20. PubMed ID: 16685897
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A rate-controlled indentor for in vivo analysis of residual limb tissues.
    Pathak AP; Silver-Thorn MB; Thierfelder CA; Prieto TE
    IEEE Trans Rehabil Eng; 1998 Mar; 6(1):12-20. PubMed ID: 9535519
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Toward an MRI-based method to measure non-uniform cartilage deformation: an MRI-cyclic loading apparatus system and steady-state cyclic displacement of articular cartilage under compressive loading.
    Neu CP; Hull ML
    J Biomech Eng; 2003 Apr; 125(2):180-8. PubMed ID: 12751279
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new soft-tissue indentation model for estimating circular indenter 'force-displacement' characteristics.
    Al-ja'afreh T; Zweiri Y; Seneviratne L; Althoefer K
    Proc Inst Mech Eng H; 2008 Jul; 222(5):805-15. PubMed ID: 18756697
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A simple measuring device for laboratory indentation tests on cartilage.
    Koeller W; Kunow J; Ostermeyer O; Stomberg P; Boos C; Russlies M
    Biomed Tech (Berl); 2008 Apr; 53(2):59-64. PubMed ID: 18979621
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measuring the elastic modulus of ex vivo small tissue samples.
    Samani A; Bishop J; Luginbuhl C; Plewes DB
    Phys Med Biol; 2003 Jul; 48(14):2183-98. PubMed ID: 12894978
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a mechanical stimulator and force measurement system for the assessment of nociceptive thresholds in pigs.
    Sandercock DA; Gibson IF; Brash HM; Rutherford KM; Scott EM; Nolan AM
    J Neurosci Methods; 2009 Aug; 182(1):64-70. PubMed ID: 19505499
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimates of echo correlation and measurement bias in acoustic radiation force impulse imaging.
    McAleavey SA; Nightingale KR; Trahey GE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Jun; 50(6):631-41. PubMed ID: 12839175
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiation force imaging of viscoelastic properties with reduced artifacts.
    Viola F; Walker WF
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Jun; 50(6):736-42. PubMed ID: 12839188
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel device to evaluate the stiffness of ankle-foot orthosis devices.
    Cappa P; Patanè F; Pierro MM
    J Biomech Eng; 2003 Dec; 125(6):913-7. PubMed ID: 14986419
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An integrated system for real-time detection of stiff masses with a single compression.
    Fahmy AS; Krieger A; Osman NF
    IEEE Trans Biomed Eng; 2006 Jul; 53(7):1286-93. PubMed ID: 16830933
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Semianalytical Solution for the Deformation of an Elastic Layer under an Axisymmetrically Distributed Power-Form Load: Application to Fluid-Jet-Induced Indentation of Biological Soft Tissues.
    Lu M; Huang S; Yang X; Yang L; Mao R
    Biomed Res Int; 2017; 2017():9842037. PubMed ID: 28373991
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A continuous loading apparatus for measuring three-dimensional stiffness of ankle-foot orthoses.
    Cappa P; Patanè F; Di Rosa G
    J Biomech Eng; 2005 Nov; 127(6):1025-9. PubMed ID: 16438244
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel MRI compatible soft tissue indentor and fibre Bragg grating force sensor.
    Moerman KM; Sprengers AM; Nederveen AJ; Simms CK
    Med Eng Phys; 2013 Apr; 35(4):486-99. PubMed ID: 22819569
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel method to obtain modulus image of soft tissues using ultrasound water jet indentation: a phantom study.
    Lu MH; Zheng YP; Huang QH
    IEEE Trans Biomed Eng; 2007 Jan; 54(1):114-21. PubMed ID: 17260862
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Probing elastic modulus and depth of bottom-supported inclusions in model tissues using piezoelectric cantilevers.
    Yegingil H; Shih WY; Shih WH
    Rev Sci Instrum; 2007 Nov; 78(11):115101. PubMed ID: 18052498
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.