BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 21112714)

  • 1. Multipolar radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver: correlation between volume of coagulation and amount of applied energy.
    Clasen S; Rempp H; Schmidt D; Schraml C; Hoffmann R; Claussen CD; Pereira PL
    Eur J Radiol; 2012 Jan; 81(1):111-3. PubMed ID: 21112714
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bipolar radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver: prediction of coagulation volume from applied energy.
    Clasen S; Schmidt D; Dietz K; Boss A; Kröber SM; Schraml C; Fritz J; Claussen CD; Pereira PL
    Invest Radiol; 2007 Jan; 42(1):29-36. PubMed ID: 17213746
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling.
    Clasen S; Schmidt D; Boss A; Dietz K; Kröber SM; Claussen CD; Pereira PL
    Radiology; 2006 Mar; 238(3):881-90. PubMed ID: 16424244
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Internally cooled bipolar radiofrequency ablation: is a lower power output more effective?].
    Clasen S; Geng A; Herberts T; Boss A; Schmidt D; Schraml C; Fritz J; Kröber SM; Claussen CD; Pereira PL
    Rofo; 2007 Mar; 179(3):282-8. PubMed ID: 17301932
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multipolar radiofrequency ablation using 4-6 applicators simultaneously: a study in the ex vivo bovine liver.
    Stoffner R; Kremser C; Schullian P; Haidu M; Widmann G; Bale RJ
    Eur J Radiol; 2012 Oct; 81(10):2568-75. PubMed ID: 22297178
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Switching monopolar radiofrequency ablation technique using multiple, internally cooled electrodes and a multichannel generator: ex vivo and in vivo pilot study.
    Lee JM; Han JK; Kim HC; Choi YH; Kim SH; Choi JY; Choi BI
    Invest Radiol; 2007 Mar; 42(3):163-71. PubMed ID: 17287646
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.
    Rempp H; Voigtländer M; Clasen S; Kempf S; Neugebauer A; Schraml C; Schmidt D; Claussen CD; Enderle MD; Goldberg SN; Pereira PL
    Invest Radiol; 2009 Dec; 44(12):763-8. PubMed ID: 19838120
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ex vivo evaluation of a bipolar application concept for radiofrequency ablation.
    Zurbuchen U; Frericks B; Roggan A; Lehmann K; Bössenroth D; Buhr HJ; Ritz JP
    Anticancer Res; 2009 Apr; 29(4):1309-14. PubMed ID: 19414380
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of a single perfusion device and an internally cooled cluster device: laboratory experience in ex vivo liver tissue with longer duration of energy application.
    Schmidt D; Clasen S; Boss A; Herberts T; Aubé C; Truebenbach J; Claussen CD; Pereira PL
    J Vasc Interv Radiol; 2009 Apr; 20(4):524-31. PubMed ID: 19328429
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of NaCl concentrations on coagulation, temperature, and electrical conductivity using a perfusion radiofrequency ablation system: an ex vivo experimental study.
    Aubé C; Schmidt D; Brieger J; Schenk M; Kroeber S; Vielle B; Claussen CD; Goldberg SN; Pereira PL
    Cardiovasc Intervent Radiol; 2007; 30(1):92-7. PubMed ID: 17103104
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fluid-modulated bipolar radiofrequency ablation: an ex-vivo evaluation study.
    Bruners P; Müller H; Günther RW; Schmitz-Rode T; Mahnken AH
    Acta Radiol; 2008 Apr; 49(3):258-66. PubMed ID: 18365809
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hybrid radiofrequency and cryoablation device: preliminary results in an animal model.
    Hines-Peralta A; Hollander CY; Solazzo S; Horkan C; Liu ZJ; Goldberg SN
    J Vasc Interv Radiol; 2004 Oct; 15(10):1111-20. PubMed ID: 15466798
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Technical characterization of a new bipolar and multipolar radiofrequency device for minimally invasive treatment of renal tumours.
    Häcker A; Vallo S; Weiss C; Stein T; Alken P; Knoll T; Michel MS
    BJU Int; 2006 Apr; 97(4):822-8. PubMed ID: 16536782
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-power generator for radiofrequency ablation: larger electrodes and pulsing algorithms in bovine ex vivo and porcine in vivo settings.
    Solazzo SA; Ahmed M; Liu Z; Hines-Peralta AU; Goldberg SN
    Radiology; 2007 Mar; 242(3):743-50. PubMed ID: 17244719
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of internally water-perfused and cryogenically cooled monopolar and bipolar radiofrequency applicators in ex vivo liver samples.
    Rempp H; Mezger D; Voigtlaender M; Scharpf M; Hoffmann R; Pereira PL; Enderle MD; Claussen CD; Clasen S
    Acad Radiol; 2014 May; 21(5):661-6. PubMed ID: 24703480
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of microwave ablation and multipolar radiofrequency ablation in vivo using two internally cooled probes.
    Fan W; Li X; Zhang L; Jiang H; Zhang J
    AJR Am J Roentgenol; 2012 Jan; 198(1):W46-50. PubMed ID: 22194514
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: laboratory and clinical experience in liver metastases.
    Goldberg SN; Solbiati L; Hahn PF; Cosman E; Conrad JE; Fogle R; Gazelle GS
    Radiology; 1998 Nov; 209(2):371-9. PubMed ID: 9807561
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Radiofrequency ablation using a new type of internally cooled electrode with an adjustable active tip: an experimental study in ex vivo bovine and in vivo porcine livers.
    Cha J; Kim YS; Rhim H; Lim HK; Choi D; Lee MW
    Eur J Radiol; 2011 Mar; 77(3):516-21. PubMed ID: 19800188
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wet radio-frequency ablation using multiple electrodes: comparative study of bipolar versus monopolar modes in the bovine liver.
    Lee JM; Han JK; Kim SH; Han CJ; An SK; Lee JY; Choi BI
    Eur J Radiol; 2005 Jun; 54(3):408-17. PubMed ID: 15899344
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiofrequency hepatic ablation with internally cooled electrodes and hybrid applicators with distant saline infusion using an in vivo porcine model.
    Burdío F; Navarro A; Berjano EJ; Burdío JM; Gonzalez A; Güemes A; Sousa R; Rufas M; Cruz I; Castiella T; Lozano R; Lequerica JL; Grande L
    Eur J Surg Oncol; 2008 Jul; 34(7):822-30. PubMed ID: 18042500
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.