BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 2111757)

  • 1. Evaluation of metabolic measuring instruments for use in critically ill patients.
    Makita K; Nunn JF; Royston B
    Crit Care Med; 1990 Jun; 18(6):638-44. PubMed ID: 2111757
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of methods for indirect calorimetry with a ventilated lung model.
    Braun U; Zundel J; Freiboth K; Weyland W; Turner E; Heidelmeyer CF; Hellige G
    Intensive Care Med; 1989; 15(3):196-202. PubMed ID: 2500469
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro evaluation of a compact metabolic measurement instrument.
    Weissman C; Sardar A; Kemper M
    JPEN J Parenter Enteral Nutr; 1990; 14(2):216-21. PubMed ID: 2112632
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A validation and comparison study of two metabolic monitors.
    Phang PT; Rich T; Ronco J
    JPEN J Parenter Enteral Nutr; 1990; 14(3):259-61. PubMed ID: 2112638
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An in vitro evaluation of an instrument designed to measure oxygen consumption and carbon dioxide production during mechanical ventilation.
    Weissman C; Sardar A; Kemper M
    Crit Care Med; 1994 Dec; 22(12):1995-200. PubMed ID: 7988139
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Comparison of Carbon Dioxide Elimination Measurements Between a Portable Indirect Calorimeter and Volumetric Capnography Monitor: An In Vitro Simulation.
    Smallwood CD; Martinez EE; Mehta NM
    Respir Care; 2016 Mar; 61(3):354-8. PubMed ID: 26715770
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of face mask, head hood, and canopy for breath sampling in flow-through indirect calorimetry to measure oxygen consumption and carbon dioxide production of preterm infants < 1500 grams.
    Bauer K; Pasel K; Uhrig C; Sperling P; Versmold H
    Pediatr Res; 1997 Jan; 41(1):139-44. PubMed ID: 8979303
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro validation of a metabolic monitor for gas exchange measurements in ventilated neonates.
    Behrends M; Kernbach M; Bräuer A; Braun U; Peters J; Weyland W
    Intensive Care Med; 2001 Jan; 27(1):228-35. PubMed ID: 11280640
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Continuous non-invasive monitoring of energy expenditure, oxygen consumption and alveolar ventilation during controlled ventilation: validation in an oxygen consuming lung model.
    Holk K; Einarsson SG; Svensson KL; Bengtson JP; Stenqvist O
    Acta Anaesthesiol Scand; 1996 May; 40(5):530-7. PubMed ID: 8792881
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Evaluation of the Engstrom metabolic computer].
    Lepape A; Perdrix JP; Grozel JM; Roche P; Banssillon V
    Ann Fr Anesth Reanim; 1987; 6(2):129-32. PubMed ID: 3473954
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the accuracy and precision of a new generation indirect calorimeter in canopy dilution mode.
    Delsoglio M; Dupertuis YM; Oshima T; van der Plas M; Pichard C
    Clin Nutr; 2020 Jun; 39(6):1927-1934. PubMed ID: 31543335
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A water-sealed indirect calorimeter for measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), and energy expenditure in infants.
    Dechert RE; Wesley JR; Schafer LE; LaMond S; Nicks J; Coran AG; Bartlett RH
    JPEN J Parenter Enteral Nutr; 1988; 12(3):256-9. PubMed ID: 3134559
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of gas leak around endotracheal tubes on indirect calorimetry measurement.
    Dietrich KA; Romero MD; Conrad SA
    JPEN J Parenter Enteral Nutr; 1990; 14(4):408-13. PubMed ID: 2119449
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of ventilator resetting on indirect calorimetry measurement in the critically ill surgical patient.
    Brandi LS; Bertolini R; Santini L; Cavani S
    Crit Care Med; 1999 Mar; 27(3):531-9. PubMed ID: 10199532
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Methods to validate the accuracy of an indirect calorimeter in the in-vitro setting.
    Oshima T; Ragusa M; Graf S; Dupertuis YM; Heidegger CP; Pichard C
    Clin Nutr ESPEN; 2017 Dec; 22():71-75. PubMed ID: 29415838
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous breathing circuit flow and tracheal tube cuff leak: sources of error during pediatric indirect calorimetry.
    Räsänen J
    Crit Care Med; 1992 Sep; 20(9):1335-40. PubMed ID: 1521450
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The indirect calorimeter, "do it yourself"].
    Bachour K; Neidhardt A; Costes Y; Fergane ; Flicoteaux H
    Agressologie; 1990 Jan; 31(1):64-7. PubMed ID: 2363485
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measuring energy expenditure in the intensive care unit: a comparison of indirect calorimetry by E-sCOVX and Quark RMR with Deltatrac II in mechanically ventilated critically ill patients.
    Rehal MS; Fiskaare E; Tjäder I; Norberg Å; Rooyackers O; Wernerman J
    Crit Care; 2016 Mar; 20():54. PubMed ID: 26951095
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of FiO
    Ferreruela M; Raurich JM; Llompart-Pou JA; Colomar A; Ayestarán I
    Med Intensiva; 2017 Nov; 41(8):461-467. PubMed ID: 28283325
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a non-invasive method for the measurement of metabolic rate in humans.
    Weissman C; Damask MC; Askanazi J; Rosenbaum SH; Kinney JM
    Clin Sci (Lond); 1985 Aug; 69(2):135-41. PubMed ID: 3933889
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.