These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
199 related articles for article (PubMed ID: 21118189)
1. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 - practical use, including problems, and their use with paediatric patients. Wilkes AR Anaesthesia; 2011 Jan; 66(1):40-51. PubMed ID: 21118189 [TBL] [Abstract][Full Text] [Related]
2. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1 - history, principles and efficiency. Wilkes AR Anaesthesia; 2011 Jan; 66(1):31-9. PubMed ID: 21106035 [TBL] [Abstract][Full Text] [Related]
3. Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system. Parmar V J Indian Med Assoc; 2008 Aug; 106(8):533-5, 537. PubMed ID: 18975515 [TBL] [Abstract][Full Text] [Related]
4. Passage of pathogenic microorganisms through breathing system filters used in anaesthesia and intensive care. Scott DH; Fraser S; Willson P; Drummond GB; Baillie JK Anaesthesia; 2010 Jul; 65(7):670-3. PubMed ID: 20374232 [TBL] [Abstract][Full Text] [Related]
5. The use of filters with small infants. Whitelock DE; de Beer DA Respir Care Clin N Am; 2006 Jun; 12(2):307-20. PubMed ID: 16828697 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of the efficiency of heat and moisture exchangers during paediatric anaesthesia. Luchetti M; Pigna A; Gentili A; Marraro G Paediatr Anaesth; 1999; 9(1):39-45. PubMed ID: 10712714 [TBL] [Abstract][Full Text] [Related]
8. Mechanical effects of heat-moisture exchangers in ventilated patients. Iotti GA; Olivei MC; Braschi A Crit Care; 1999; 3(5):R77-82. PubMed ID: 11094485 [TBL] [Abstract][Full Text] [Related]
9. The pall ultipor breathing circuit filter--an efficient heat and moisture exchanger. Chalon J; Markham JP; Ali MM; Ramanathan S; Turndorf H Anesth Analg; 1984 Jun; 63(6):566-70. PubMed ID: 6731877 [TBL] [Abstract][Full Text] [Related]
10. Rapid and complete occlusion of a heat and moisture exchange filter by pulmonary edema (clinical report). Williams DJ; Stacey MR Can J Anaesth; 2002 Feb; 49(2):126-31. PubMed ID: 11823388 [TBL] [Abstract][Full Text] [Related]
11. Bacterial and viral removal efficiency, heat and moisture exchange properties of four filtration devices. Vanderbroucke-Grauls CM; Teeuw KB; Ballemans K; Lavooij C; Cornelisse PB; Verhoef J J Hosp Infect; 1995 Jan; 29(1):45-56. PubMed ID: 7738339 [TBL] [Abstract][Full Text] [Related]
13. The effect of a heat and moisture exchanger on gas flow in a Mapleson F breathing system during inhalational induction. Da Fonseca JM; Wheeler DW; Pook JA Anaesthesia; 2000 Jun; 55(6):571-3. PubMed ID: 10866720 [TBL] [Abstract][Full Text] [Related]
14. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia. Boots RJ; George N; Faoagali JL; Druery J; Dean K; Heller RF Crit Care Med; 2006 Mar; 34(3):687-93. PubMed ID: 16505654 [TBL] [Abstract][Full Text] [Related]
15. [Are humidity filters necessary in the inspired air in the breathing circuit? A new in vivo method of measuring humidity in the air breathed]. Kohler P; Rimek A; Albrecht M; Frankenberger H; Mertins W; van Ackern K Anasthesiol Intensivmed Notfallmed Schmerzther; 1992 May; 27(3):149-55. PubMed ID: 1617027 [TBL] [Abstract][Full Text] [Related]
16. [Device for humidifying and heating of respiratory mixture during artificial respiration in pediatric anesthesiology]. Trilitskiĭ VP; Nemets VD Anesteziol Reanimatol; 1981; (5):73-4. PubMed ID: 7325392 [No Abstract] [Full Text] [Related]
17. [Measurement of flow-resistive work of heat and moisture exchangers during simulated active breathing]. Nishimura M; Takezawa J; Imanaka H; Taenaka N; Yoshiya I Masui; 1990 Jun; 39(6):695-700. PubMed ID: 2388387 [TBL] [Abstract][Full Text] [Related]
18. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min. Martin C; Papazian L; Perrin G; Saux P; Gouin F Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294 [TBL] [Abstract][Full Text] [Related]
19. The effect of flow on the filtration performance of paediatric breathing system filters. Wilkes AR; Malan CA; Hall JE Anaesthesia; 2008 Jan; 63(1):71-6. PubMed ID: 18086073 [TBL] [Abstract][Full Text] [Related]
20. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients. Campbell RS; Davis K; Johannigman JA; Branson RD Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]