These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
263 related articles for article (PubMed ID: 21119230)
1. Accurate Monte Carlo modelling of the back compartments of SPECT cameras. Rault E; Staelens S; Van Holen R; De Beenhouwer J; Vandenberghe S Phys Med Biol; 2011 Jan; 56(1):87-104. PubMed ID: 21119230 [TBL] [Abstract][Full Text] [Related]
2. Validation of the Monte Carlo simulator GATE for indium-111 imaging. Assié K; Gardin I; Véra P; Buvat I Phys Med Biol; 2005 Jul; 50(13):3113-25. PubMed ID: 15972984 [TBL] [Abstract][Full Text] [Related]
3. Monte Carlo simulation of energy spectra for (123)I imaging. Tanaka M; Uehara S; Kojima A; Matsumoto M Phys Med Biol; 2007 Aug; 52(15):4409-25. PubMed ID: 17634641 [TBL] [Abstract][Full Text] [Related]
4. Monte Carlo modeling of gamma cameras for I-131 imaging in targeted radiotherapy. Autret D; Bitar A; Ferrer L; Lisbona A; Bardiès M Cancer Biother Radiopharm; 2005 Feb; 20(1):77-84. PubMed ID: 15778585 [TBL] [Abstract][Full Text] [Related]
5. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system. Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362 [TBL] [Abstract][Full Text] [Related]
6. Hybrid scatter correction applied to quantitative holmium-166 SPECT. de Wit TC; Xiao J; Nijsen JF; van het Schip FD; Staelens SG; van Rijk PP; Beekman FJ Phys Med Biol; 2006 Oct; 51(19):4773-87. PubMed ID: 16985270 [TBL] [Abstract][Full Text] [Related]
7. Quantitative Monte Carlo-based holmium-166 SPECT reconstruction. Elschot M; Smits ML; Nijsen JF; Lam MG; Zonnenberg BA; van den Bosch MA; Viergever MA; de Jong HW Med Phys; 2013 Nov; 40(11):112502. PubMed ID: 24320461 [TBL] [Abstract][Full Text] [Related]
8. Fast hybrid SPECT simulation including efficient septal penetration modelling (SP-PSF). Staelens S; de Wit T; Beekman F Phys Med Biol; 2007 Jun; 52(11):3027-43. PubMed ID: 17505087 [TBL] [Abstract][Full Text] [Related]
9. Photon energy recovery: a method to improve the effective energy resolution of gamma cameras. Hannequin PP; Mas JF J Nucl Med; 1998 Mar; 39(3):555-62. PubMed ID: 9529311 [TBL] [Abstract][Full Text] [Related]
10. Monte Carlo simulations of compact gamma cameras based on avalanche photodiodes. Després P; Funk T; Shah KS; Hasegawa BH Phys Med Biol; 2007 Jun; 52(11):3057-74. PubMed ID: 17505089 [TBL] [Abstract][Full Text] [Related]
11. Fast simulation of yttrium-90 bremsstrahlung photons with GATE. Rault E; Staelens S; Van Holen R; De Beenhouwer J; Vandenberghe S Med Phys; 2010 Jun; 37(6):2943-50. PubMed ID: 20632606 [TBL] [Abstract][Full Text] [Related]
12. Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation. Beekman FJ; de Jong HW; van Geloven S IEEE Trans Med Imaging; 2002 Aug; 21(8):867-77. PubMed ID: 12472260 [TBL] [Abstract][Full Text] [Related]
13. Monte Carlo simulation of the basic features of the GE Millennium MG single photon emission computed tomography gamma camera. Vieira L; Vaz TF; Costa DC; Almeida P Rev Esp Med Nucl Imagen Mol; 2014; 33(1):6-13. PubMed ID: 23726248 [TBL] [Abstract][Full Text] [Related]
14. Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/ 123I SPECT imaging. Ouyang J; El Fakhri G; Moore SC Med Phys; 2007 Aug; 34(8):3263-72. PubMed ID: 17879789 [TBL] [Abstract][Full Text] [Related]
15. Collimator and energy window optimization for ⁹⁰Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study. Roshan HR; Mahmoudian B; Gharepapagh E; Azarm A; Pirayesh Islamian J Appl Radiat Isot; 2016 Feb; 108():124-128. PubMed ID: 26720261 [TBL] [Abstract][Full Text] [Related]
16. Slit slat collimator optimization with respect to MTF. Kamali-Asl A; Sarkar S; Shahriari M; Agha-Hosseini H Appl Radiat Isot; 2005 Mar; 62(3):461-8. PubMed ID: 15607925 [TBL] [Abstract][Full Text] [Related]
17. Study of the point spread function (PSF) for 123I SPECT imaging using Monte Carlo simulation. Cot A; Sempau J; Pareto D; Bullich S; Pavía J; Calviño F; Ros D Phys Med Biol; 2004 Jul; 49(14):3125-36. PubMed ID: 15357186 [TBL] [Abstract][Full Text] [Related]
18. A parallel-cone collimator for high-energy SPECT. Beijst C; Elschot M; Viergever MA; de Jong HW J Nucl Med; 2015 Mar; 56(3):476-82. PubMed ID: 25655627 [TBL] [Abstract][Full Text] [Related]
19. Monte Carlo simulations of clinical PET and SPECT scans: impact of the input data on the simulated images. Stute S; Carlier T; Cristina K; Noblet C; Martineau A; Hutton B; Barnden L; Buvat I Phys Med Biol; 2011 Oct; 56(19):6441-57. PubMed ID: 21934192 [TBL] [Abstract][Full Text] [Related]
20. Determination of the detective quantum efficiency of gamma camera systems: a Monte Carlo study. Eriksson I; Starck SA; Båth M Radiat Prot Dosimetry; 2010; 139(1-3):219-27. PubMed ID: 20172935 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]