These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 21121686)

  • 41. Microkinetic coagulation assays for human and zebrafish plasma.
    Iyer N; Jagadeeswaran P
    Blood Coagul Fibrinolysis; 2021 Jan; 32(1):50-56. PubMed ID: 33186131
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The First-Derivative Curve of the Coagulation Waveform Reveals the Cause of aPTT Prolongation.
    Shimomura D; Matsumoto T; Sugimoto K; Takata T; Kouno A; Shimada M; Matsuo S; Kamioka M
    Clin Appl Thromb Hemost; 2020; 26():1076029620978810. PubMed ID: 33372824
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Artifactual prolongation of activated partial thromboplastin time with PEGylated compounds in silica-based assays.
    Murphy B; Parrula MC; Perigard CJ; Li J
    Blood Coagul Fibrinolysis; 2014 Dec; 25(8):876-82. PubMed ID: 25192241
    [TBL] [Abstract][Full Text] [Related]  

  • 44. On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system.
    Song H; Li HW; Munson MS; Van Ha TG; Ismagilov RF
    Anal Chem; 2006 Jul; 78(14):4839-49. PubMed ID: 16841902
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Progress curve analysis of microtitre plate plasma clotting assays. Assessment of tissue factor levels.
    Humphries TLR; Johnson LA; Masci PP; Gobe GC; Vesey DA
    Anal Biochem; 2021 Feb; 614():114060. PubMed ID: 33271154
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Clot waveform analysis: Where do we stand in 2017?
    Sevenet PO; Depasse F
    Int J Lab Hematol; 2017 Dec; 39(6):561-568. PubMed ID: 28876509
    [TBL] [Abstract][Full Text] [Related]  

  • 47. New evidence for intrinsic blood coagulation in chickens.
    Doerr JA; Hamilton PB
    Poult Sci; 1981 Jan; 60(1):237-42. PubMed ID: 7232266
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Measurement of plasma clotting time using ultrasonic shear waves.
    Alves CH; Machado JC
    Physiol Meas; 1994 Aug; 15(3):309-16. PubMed ID: 7994209
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Sensitivity of the Azure heparin assay and comparisons with activated clotting time and whole blood partial thromboplastin time.
    Salley SO; Whittlesey GC; Smith SM; Klein MD
    ASAIO Trans; 1990; 36(3):M687-91. PubMed ID: 2252784
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Measurement of the viscoelastic properties of blood plasma clot formation in response to tissue factor concentration-dependent activation.
    Lakshmanan RS; Efremov V; O'Donnell JS; Killard AJ
    Anal Bioanal Chem; 2016 Sep; 408(24):6581-8. PubMed ID: 27311950
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Activated partial thromboplastin time (APTT), partial thromboplastin time (PTT)].
    Shimazu C; Fukuda T
    Nihon Rinsho; 2004 Dec; 62 Suppl 12():590-3. PubMed ID: 15658397
    [No Abstract]   [Full Text] [Related]  

  • 52. The activated partial thromboplastin time-clot waveform analysis in hemophilia: Does it help in differentiation?
    Mannan KA; Kumar N; Ahluwalia J; Hans C; Kler A; Prakash G; Jain R
    Int J Lab Hematol; 2023 Apr; 45(2):241-249. PubMed ID: 36495061
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Measurement of the ultrasonic attenuation coefficient of human blood plasma during clotting in the frequency range of 8 to 22 MHz.
    Calor-Filho MM; Machado JC
    Ultrasound Med Biol; 2006 Jul; 32(7):1055-64. PubMed ID: 16829319
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Pseudo-prolongation of the partial thromboplastin time.
    Smith LG; Kitchens CS
    Am J Clin Pathol; 1983 Nov; 80(5):750-2. PubMed ID: 6637887
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Loss of anticoagulant effect of heparin during circulation of human blood in vitro.
    Pijl AJ; Solen KA; Mohammad SF; Monson R; Yu LS; van Griensven JM; Olsen DB; Kolff WJ
    Artif Organs; 1990 Apr; 14(2):125-9. PubMed ID: 2350258
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Ultrasonic method for monitoring the clotting process during whole blood coagulation.
    Voleisis A; Kazys R; Voleisiene B; Sliteris R; Mazeika L
    Ultrasonics; 2017 Jul; 78():146-151. PubMed ID: 28347872
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Activated partial thromboplastin time (APTT). New indications for an old test?
    Tripodi A; Mannucci PM
    J Thromb Haemost; 2006 Apr; 4(4):750-1. PubMed ID: 16634741
    [No Abstract]   [Full Text] [Related]  

  • 58. Evaluation of an ultrasonic method applied to the measurement of blood coagulation time.
    Machado JC; von Kruger MA; Fontes EM; de Almeida MM
    Physiol Meas; 1997 May; 18(2):129-43. PubMed ID: 9183807
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The multiple faces of the partial thromboplastin time APTT.
    Rapaport SI; Vermylen J; Hoylaerts M; Saito H; Hirsh J; Bates S; Dahlbäck B; Poller L
    J Thromb Haemost; 2004 Dec; 2(12):2250-9. PubMed ID: 15613038
    [No Abstract]   [Full Text] [Related]  

  • 60. Magnetic coagulometry: towards a new nanotechnological tool for
    Santana-Otero A; Harper A; Telling N; Ortega D; Cabrera D
    Nanoscale; 2024 Feb; 16(7):3534-3548. PubMed ID: 38285061
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.