BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

832 related articles for article (PubMed ID: 21122454)

  • 1. [Corrosion resistance of Ti-Cu alloy].
    Song YX; Wang SM
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Sep; 45(9):565-8. PubMed ID: 21122454
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys.
    Iijima M; Endo K; Ohno H; Mizoguchi I
    Dent Mater J; 1998 Mar; 17(1):31-40. PubMed ID: 9663060
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants.
    Fathi MH; Salehi M; Saatchi A; Mortazavi V; Moosavi SB
    Dent Mater; 2003 May; 19(3):188-98. PubMed ID: 12628430
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Potentiodynamic polarization study of the in vitro corrosion behavior of 3 high-palladium alloys and a gold-palladium alloy in 5 media.
    Sun D; Monaghan P; Brantley WA; Johnston WM
    J Prosthet Dent; 2002 Jan; 87(1):86-93. PubMed ID: 11807489
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of Ag on the corrosion behavior of Ti-Ag alloys in artificial saliva solutions.
    Zhang BB; Zheng YF; Liu Y
    Dent Mater; 2009 May; 25(5):672-7. PubMed ID: 19150734
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti-13Nb-13Zr alloy, and an austenitic stainless steel in Hank's solution.
    Assis SL; Rogero SO; Antunes RA; Padilha AF; Costa I
    J Biomed Mater Res B Appl Biomater; 2005 Apr; 73(1):109-16. PubMed ID: 15660438
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Corrosion behavior and microstructures of experimental Ti-Au alloys.
    Takahashi M; Kikuchi M; Takada Y; Okuno O; Okabe T
    Dent Mater J; 2004 Jun; 23(2):109-16. PubMed ID: 15287555
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Corrosion characteristics of alpha-Ti and Ti2Cu composing Ti-Cu alloys.
    Takada Y; Okuno O
    Dent Mater J; 2005 Dec; 24(4):610-6. PubMed ID: 16445025
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro evaluation of the electrochemical behaviour of stainless steel and Ni-Ti orthodontic archwires at different temperatures.
    Pakshir M; Bagheri T; Kazemi MR
    Eur J Orthod; 2013 Aug; 35(4):407-13. PubMed ID: 21771804
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion behavior of biomedical Ti-24Nb-4Zr-8Sn alloy in different simulated body solutions.
    Bai Y; Hao YL; Li SJ; Hao YQ; Yang R; Prima F
    Mater Sci Eng C Mater Biol Appl; 2013 May; 33(4):2159-67. PubMed ID: 23498244
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
    Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I
    Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires.
    Rondelli G; Vicentini B
    Biomaterials; 1999 Apr; 20(8):785-92. PubMed ID: 10353661
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrochemical corrosion behavior and elasticity properties of Ti-6Al-xFe alloys for biomedical applications.
    Lu J; Zhao Y; Niu H; Zhang Y; Du Y; Zhang W; Huo W
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():36-44. PubMed ID: 26952395
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dealloying and electroformation in high-Pd dental alloys.
    Sarkar NK; Berzins DW; Prasad A
    Dent Mater; 2000 Sep; 16(5):374-9. PubMed ID: 10915899
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electrochemical behavior of cast Ti-Ag alloys.
    Takahashi M; Kikuchi M; Takadai Y; Okabe T; Okuno O
    Dent Mater J; 2006 Sep; 25(3):516-23. PubMed ID: 17076322
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microstructure, mechanical properties, castability and in vitro biocompatibility of Ti-Bi alloys developed for dental applications.
    Qiu KJ; Liu Y; Zhou FY; Wang BL; Li L; Zheng YF; Liu YH
    Acta Biomater; 2015 Mar; 15():254-65. PubMed ID: 25595472
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Potentiodynamic polarization study of the corrosion behavior of palladium-silver dental alloys.
    Sun D; Brantley WA; Frankel GS; Heshmati RH; Johnston WM
    J Prosthet Dent; 2018 Apr; 119(4):650-656. PubMed ID: 28965676
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Corrosion and wear behavior of Ti-5Cu-xNb biomedical alloy in simulated body fluid for dental implant applications.
    Pandey AK; Gautam RK; Behera CK
    J Mech Behav Biomed Mater; 2023 Jan; 137():105533. PubMed ID: 36335694
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrochemical properties of suprastructures galvanically coupled to a titanium implant.
    Oh KT; Kim KN
    J Biomed Mater Res B Appl Biomater; 2004 Aug; 70(2):318-31. PubMed ID: 15264315
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 42.