These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
245 related articles for article (PubMed ID: 21129347)
1. Analysis of point-of-care and over-the-counter testing methods for hemoglobin A1c: how good do they need to be? Little RR J Diabetes Sci Technol; 2010 Nov; 4(6):1504-6. PubMed ID: 21129347 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of an over-the-counter glycated hemoglobin (A1C) test kit. Chang A; Frank J; Knaebel J; Fullam J; Pardo S; Simmons DA J Diabetes Sci Technol; 2010 Nov; 4(6):1495-503. PubMed ID: 21129346 [TBL] [Abstract][Full Text] [Related]
3. Accuracy and clinical utility of a point-of-care HbA1c testing device. Knaebel J; Irvin BR; Xie CZ Postgrad Med; 2013 May; 125(3):91-8. PubMed ID: 23748510 [TBL] [Abstract][Full Text] [Related]
5. Point-of-Care HbA1c in Clinical Practice: Caveats and Considerations for Optimal Use. Sacks DB; Kirkman MS; Little RR Diabetes Care; 2024 Jul; 47(7):1104-1110. PubMed ID: 38552140 [TBL] [Abstract][Full Text] [Related]
6. Accuracy and Precision of a Point-of-Care HbA1c Test. Arnold WD; Kupfer K; Little RR; Amar M; Horowitz B; Godbole N; Hvidsten Swensen M; Li Y; San George RC J Diabetes Sci Technol; 2020 Sep; 14(5):883-889. PubMed ID: 30854894 [TBL] [Abstract][Full Text] [Related]
7. A1c Gear: Laboratory quality HbA1c measurement at the point of care. Ejilemele A; Unabia J; Ju H; Petersen JR Clin Chim Acta; 2015 May; 445():139-42. PubMed ID: 25801216 [TBL] [Abstract][Full Text] [Related]
8. Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis. Health Quality Ontario Ont Health Technol Assess Ser; 2014; 14(8):1-30. PubMed ID: 26316922 [TBL] [Abstract][Full Text] [Related]
9. HbA Kenealy T; Herd G; Musaad S; Wells S Prim Care Diabetes; 2019 Apr; 13(2):170-175. PubMed ID: 30545795 [TBL] [Abstract][Full Text] [Related]
10. Analysis of the accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device. Little RR J Diabetes Sci Technol; 2012 Mar; 6(2):387-8. PubMed ID: 22538151 [TBL] [Abstract][Full Text] [Related]
11. Study of the effect of altitude on the measurement of glycated haemoglobin using point-of-care instruments. Veigne SW; Sobngwi E; Nouthe BE; Sobngwi-Tambekou J; Balti EV; Limen S; Dehayem MY; Ama V; Nguewa J; Ndour-Mbaye M; Camara A; Balde NM; Mbanya J Cardiovasc J Afr; 2015; 26(1):38-40. PubMed ID: 25784316 [TBL] [Abstract][Full Text] [Related]
12. Quality of HbA1c Measurement in the Practice: The German Perspective. Heinemann L; Freckmann G J Diabetes Sci Technol; 2015 May; 9(3):687-95. PubMed ID: 25691655 [TBL] [Abstract][Full Text] [Related]
13. Fingerstick Precision and Total Error of a Point-of-Care HbA1c Test. Arnold WD; Kupfer K; Hvidsten Swensen M; Fortner KS; Bays HE; Davis M; Klaff LJ; San George RC J Diabetes Sci Technol; 2020 Sep; 14(5):890-895. PubMed ID: 30841743 [TBL] [Abstract][Full Text] [Related]
14. Assessment of Two Diabetes Point-of-care Analyzers Measuring Hemoglobin A1c in the Peruvian Amazon. Saxton AT; Miranda JJ; Ortiz EJ; Pan W Ann Glob Health; 2018 Nov; 84(4):618-624. PubMed ID: 30779508 [TBL] [Abstract][Full Text] [Related]
15. A miniaturized self-contained single-use disposable quantitatitve test for hemoglobin A1c in blood at the point of care. Stivers CR; Baddam SR; Clark AL; Ammirati EB; Irvin BR; Blatt JM Diabetes Technol Ther; 2000; 2(4):517-26. PubMed ID: 11469613 [TBL] [Abstract][Full Text] [Related]
16. Analytic bias among certified methods for the measurement of hemoglobin A1c: a cause for concern? Holmes EW; Erşahin C; Augustine GJ; Charnogursky GA; Gryzbac M; Murrell JV; McKenna KM; Nabhan F; Kahn SE Am J Clin Pathol; 2008 Apr; 129(4):540-7. PubMed ID: 18343780 [TBL] [Abstract][Full Text] [Related]
17. Performance evaluation of the glycated hemoglobin A1c analyzer for point-of-care testing compared with laboratory-based devices: a multicenter validation study. Zhou Y; Yang F; Zhou M; Pan B; Wang B; Guo W; Shao W; Zhu J Scand J Clin Lab Invest; 2024 Sep; 84(5):356-361. PubMed ID: 39217618 [TBL] [Abstract][Full Text] [Related]
18. Six of eight hemoglobin A1c point-of-care instruments do not meet the general accepted analytical performance criteria. Lenters-Westra E; Slingerland RJ Clin Chem; 2010 Jan; 56(1):44-52. PubMed ID: 19926777 [TBL] [Abstract][Full Text] [Related]
19. Multicenter assessment of a hemoglobin A1c point-of-care device for diagnosis of diabetes mellitus. Sobolesky PM; Smith BE; Saenger AK; Schulz K; Apple FS; Scott MG; Wu AHB; Little RR; Fitzgerald RL Clin Biochem; 2018 Nov; 61():18-22. PubMed ID: 30236830 [TBL] [Abstract][Full Text] [Related]
20. Glycated hemoglobin assessment in clinical practice: comparison of the A1cNow point-of-care device with central laboratory testing (GOAL A1C Study). Kennedy L; Herman WH; Diabetes Technol Ther; 2005 Dec; 7(6):907-12. PubMed ID: 16386096 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]