These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
166 related articles for article (PubMed ID: 21139536)
1. Accuracy and safety of percutaneous US-guided needle biopsies in liver metastasis and hemangiomas. Kadri Aribas B; Dingil G; Ungul U; Sahin G; Nil Unlu D; Dogan K; Simsek Z; Kaya G; Yilmaz K; Yucel E; Demir P Minerva Gastroenterol Dietol; 2010 Dec; 56(4):377-82. PubMed ID: 21139536 [TBL] [Abstract][Full Text] [Related]
2. Accuracy and safety of percutaneous US-guided needle biopsies in specific focal liver lesions: comparison of large and small needles in 1300 patients. Aribaş BK; Arda K; Ciledağ N; Aktaş E; Yakut F; Kavak S; Sahin G; Kaygusuz H Panminerva Med; 2012 Sep; 54(3):233-9. PubMed ID: 22801441 [TBL] [Abstract][Full Text] [Related]
3. Percutaneous US-guided needle biopsies of solid renal masses. Aribaş BK; Arda K; Aktaş E; Ciledağ N; Yakut F; Sahin G; Coşar Y; Doğan K; Kaya G Neoplasma; 2011; 58(2):146-52. PubMed ID: 21275465 [TBL] [Abstract][Full Text] [Related]
4. [CT-guided percutaneous biopsies for the classification of focal liver lesions: a comparison between 14 G and 18 G puncture biopsy needles]. Haage P; Piroth W; Staatz G; Adam G; Günther RW Rofo; 1999 Jul; 171(1):44-8. PubMed ID: 10464504 [TBL] [Abstract][Full Text] [Related]
5. [Liver biopsy under guidance of multislice computed tomography: comparison of 16G and 18G biopsy needles]. Stattaus J; Kühl H; Hauth EA; Kalkmann J; Baba HA; Forsting M Radiologe; 2007 May; 47(5):430-8. PubMed ID: 16440187 [TBL] [Abstract][Full Text] [Related]
7. Transthoracic ultrasonography-guided core needle biopsy of pleural-based lung lesions: prospective randomized comparison between a Tru-cut-type needle and a modified Menghini-type needle. Tombesi P; Nielsen I; Tassinari D; Trevisani L; Abbasciano V; Sartori S Ultraschall Med; 2009 Aug; 30(4):390-5. PubMed ID: 19544230 [TBL] [Abstract][Full Text] [Related]
8. Role of image-guided fine-needle aspiration biopsy in the management of patients with splenic metastasis. Cavanna L; Lazzaro A; Vallisa D; Civardi G; Artioli F World J Surg Oncol; 2007 Feb; 5():13. PubMed ID: 17274814 [TBL] [Abstract][Full Text] [Related]
9. Fine-needle trucut biopsy versus fine-needle aspiration cytology with ultrasound guidance in the abdomen. O'Connell AM; Keeling F; Given M; Logan M; Lee MJ J Med Imaging Radiat Oncol; 2008 Jun; 52(3):231-6. PubMed ID: 18477117 [TBL] [Abstract][Full Text] [Related]
10. US-guided core-needle biopsy of the thyroid gland. Screaton NJ; Berman LH; Grant JW Radiology; 2003 Mar; 226(3):827-32. PubMed ID: 12601219 [TBL] [Abstract][Full Text] [Related]
11. Percutaneous needle biopsy of the mediastinum: review of 94 procedures. Morrissey B; Adams H; Gibbs AR; Crane MD Thorax; 1993 Jun; 48(6):632-7. PubMed ID: 8346494 [TBL] [Abstract][Full Text] [Related]
13. [Application of tru-cut biopsy combined with fine needle aspiration biopsy in the intraoperative pathological diagnosis of pancreatic carcinoma]. Che X; Wang CF; Shan Y; Zhao DB; Tian YT; Sun YM; Bai XF; Wang Y; Zhang JW; Zhao P Zhonghua Zhong Liu Za Zhi; 2009 Jun; 31(6):478-80. PubMed ID: 19950564 [TBL] [Abstract][Full Text] [Related]
14. Ultrasonographically guided biopsy of thoracic tumors. A comparison of large-bore cutting biopsy with fine-needle aspiration. Yang PC; Lee YC; Yu CJ; Chang DB; Wu HD; Lee LN; Kuo SH; Luh KT Cancer; 1992 May; 69(10):2553-60. PubMed ID: 1568179 [TBL] [Abstract][Full Text] [Related]
16. Percutaneous US-guided liver biopsy in focal lesions using a semiautomatic device allowing to perform multiple biopsies in a single-pass. Tzortzis D; Revenas K; Deladetsima I; Antoniou E; Tzortzis G Minerva Gastroenterol Dietol; 2012 Mar; 58(1):1-8. PubMed ID: 22418999 [TBL] [Abstract][Full Text] [Related]
17. Adequacy of percutaneous non-targeted liver biopsy under real-time ultrasound guidance when comparing the Biopince™ and Achieve™ biopsy needle. Hall TC; Deakin C; Atwal GS; Singh RK Br J Radiol; 2017 Dec; 90(1080):20170397. PubMed ID: 28972801 [TBL] [Abstract][Full Text] [Related]
18. A case of needle tract implantation of hepatocellular carcinoma after percutaneous biopsy with an 18G Tru-cut needle. Chang S; Lim HK Korean J Hepatol; 2006 Sep; 12(3):439-43. PubMed ID: 16998296 [TBL] [Abstract][Full Text] [Related]
19. Ultrasound guided fine needle aspiration using 25G needle as a new technique for a wide range of pathological conditions. Al-Damegh SA Saudi Med J; 2004 Oct; 25(10):1374-7. PubMed ID: 15494805 [TBL] [Abstract][Full Text] [Related]
20. Percutaneous ultrasonography-guided core needle biopsy of gastrointestinal lesions: what's its actual role in clinical practice? A retrospective study for safety and effectiveness. Tombesi P; Postorivo S; Catellani M; Tassinari D; Abbasciano V; Sartori S Ultraschall Med; 2011 Jan; 32 Suppl 1():S62-7. PubMed ID: 20235004 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]