These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
239 related articles for article (PubMed ID: 21143537)
1. Effect of implant drill characteristics on heat generation in osteotomy sites: a pilot study. Oh HJ; Wikesjö UM; Kang HS; Ku Y; Eom TG; Koo KT Clin Oral Implants Res; 2011 Jul; 22(7):722-726. PubMed ID: 21143537 [TBL] [Abstract][Full Text] [Related]
2. Effects of implant drill wear, irrigation, and drill materials on heat generation in osteotomy sites. Koo KT; Kim MH; Kim HY; Wikesjö UM; Yang JH; Yeo IS J Oral Implantol; 2015 Apr; 41(2):e19-23. PubMed ID: 24313461 [TBL] [Abstract][Full Text] [Related]
3. Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills. Scarano A; Piattelli A; Assenza B; Carinci F; Di Donato L; Romani GL; Merla A Clin Implant Dent Relat Res; 2011 Dec; 13(4):319-23. PubMed ID: 19681941 [TBL] [Abstract][Full Text] [Related]
4. Influence of the implant drill design and sequence on temperature changes during site preparation. Sannino G; Capparé P; Gherlone EF; Barlattani A Int J Oral Maxillofac Implants; 2015; 30(2):351-8. PubMed ID: 25153005 [TBL] [Abstract][Full Text] [Related]
5. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Ercoli C; Funkenbusch PD; Lee HJ; Moss ME; Graser GN Int J Oral Maxillofac Implants; 2004; 19(3):335-49. PubMed ID: 15214217 [TBL] [Abstract][Full Text] [Related]
6. Heat production by 3 implant drill systems after repeated drilling and sterilization. Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899 [TBL] [Abstract][Full Text] [Related]
7. Multistepped Drill Design for Single-Stage Implant Site Preparation: Experimental Study in Type 2 Bone. Abboud M; Delgado-Ruiz RA; Kucine A; Rugova S; Balanta J; Calvo-Guirado JL Clin Implant Dent Relat Res; 2015 Oct; 17 Suppl 2():e472-85. PubMed ID: 25263993 [TBL] [Abstract][Full Text] [Related]
8. Effect of surgical drill guide on heat generated from implant drilling. Misir AF; Sumer M; Yenisey M; Ergioglu E J Oral Maxillofac Surg; 2009 Dec; 67(12):2663-8. PubMed ID: 19925988 [TBL] [Abstract][Full Text] [Related]
9. Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants. Bulloch SE; Olsen RG; Bulloch B Int J Oral Maxillofac Implants; 2012; 27(6):1456-60. PubMed ID: 23189297 [TBL] [Abstract][Full Text] [Related]
10. Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model. Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD Clin Oral Implants Res; 2021 Feb; 32(2):154-166. PubMed ID: 33220104 [TBL] [Abstract][Full Text] [Related]
11. A novel, new generation drill coating for osteotomy site preparation. Wadkar PP; Khalap S; Shetty D; Gupta A; Shetty A; Dharmadhikari S Indian J Dent Res; 2019; 30(5):767-771. PubMed ID: 31854371 [TBL] [Abstract][Full Text] [Related]
12. Influence of a Novel Drill Design on Heat Generation During Conventional and Guided Implant Osteotomy. Kuster M; Mukaddam K; Zitzmann NU; Filippi A; Kühl S Int J Oral Maxillofac Implants; 2021; 36(3):e31-e41. PubMed ID: 34115057 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of bone heating, drill deformation, and drill roughness after implant osteotomy: guided surgery and classic drilling procedure. dos Santos PL; Queiroz TP; Margonar R; de Souza Carvalho AC; Betoni W; Rezende RR; dos Santos PH; Garcia IR Int J Oral Maxillofac Implants; 2014; 29(1):51-8. PubMed ID: 24451853 [TBL] [Abstract][Full Text] [Related]
14. In Vitro Assessment with the Infrared Thermometer of Temperature Differences Generated During Implant Site Preparation: The Traditional Technique Versus the Single-Drill Technique. Lucchiari N; Frigo AC; Stellini E; Coppe M; Berengo M; Bacci C Clin Implant Dent Relat Res; 2016 Feb; 18(1):182-91. PubMed ID: 25040939 [TBL] [Abstract][Full Text] [Related]
15. Thermal Changes During Guided Flapless Implant Site Preparation: A Comparative Study. Sannino G; Gherlone EF Int J Oral Maxillofac Implants; 2018; 33(3):671-677. PubMed ID: 29763502 [TBL] [Abstract][Full Text] [Related]
16. Implant Drill Characteristics: Thermal and Mechanical Effects of Two-, Three-, and Four-Fluted Drills. Oh HJ; Kim BI; Kim HY; Yeo IS; Wikesjö UM; Koo KT Int J Oral Maxillofac Implants; 2017; 32(3):483–488. PubMed ID: 27525521 [TBL] [Abstract][Full Text] [Related]
17. Drilling- and withdrawing-related thermal effects of implant site preparation for ceramic and stainless steel twist drills in standardized bovine bone. Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD Clin Implant Dent Relat Res; 2023 Feb; 25(1):152-165. PubMed ID: 36369670 [TBL] [Abstract][Full Text] [Related]
18. Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study. Delgado-Ruiz RA; Velasco Ortega E; Romanos GE; Gerhke S; Newen I; Calvo-Guirado JL Clin Oral Investig; 2018 Jan; 22(1):349-359. PubMed ID: 28434045 [TBL] [Abstract][Full Text] [Related]
19. Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills. Oliveira N; Alaejos-Algarra F; Mareque-Bueno J; Ferrés-Padró E; Hernández-Alfaro F Clin Oral Implants Res; 2012 Aug; 23(8):963-9. PubMed ID: 21806686 [TBL] [Abstract][Full Text] [Related]
20. Heat and Sound Generation During Implant Osteotomy When Using Different Types of Drills in Artificial and Bovine Bone Blocks. Limmeechokchai S; Kan JY; Rungcharassaeng K; Goodacre CJ; Lozada J; Oyoyo U J Oral Implantol; 2022 Jun; 48(3):187-193. PubMed ID: 34091687 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]