225 related articles for article (PubMed ID: 21144923)
1. History and development of suction-irrigation-reaming.
Green J
Injury; 2010 Nov; 41 Suppl 2():S24-31. PubMed ID: 21144923
[TBL] [Abstract][Full Text] [Related]
2. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur.
Husebye EE; Lyberg T; Madsen JE; Eriksen M; Røise O
Injury; 2006 Oct; 37(10):935-40. PubMed ID: 16934266
[TBL] [Abstract][Full Text] [Related]
3. A cadaver model evaluating femoral intramedullary reaming: a comparison between new reamer design (Pressure Sentinel) and a novel suction/irrigation reamer (RIA).
Goplen G; Wilson JA; McAffrey M; Deluzio K; Leighton R
Injury; 2010 Nov; 41 Suppl 2():S38-42. PubMed ID: 21144925
[TBL] [Abstract][Full Text] [Related]
4. Unreamed or RIA reamed nailing: an experimental sheep study using comparative histological assessment of affected bone tissue in an acute fracture model.
Klein C; Sprecher C; Rahn BA; Green J; Müller CA
Injury; 2010 Nov; 41 Suppl 2():S32-7. PubMed ID: 21144924
[TBL] [Abstract][Full Text] [Related]
5. Pathophysiological advantages of rinsing-suction-reaming (RSR) in a pig model for intramedullary nailing.
Schult M; Küchle R; Hofmann A; Schmidt-Bräkling T; Ortmann C; Wassermann E; Schmidhammer R; Redl H; Joist A
J Orthop Res; 2006 Jun; 24(6):1186-92. PubMed ID: 16649178
[TBL] [Abstract][Full Text] [Related]
6. Cardiopulmonary response to reamed intramedullary nailing of the femur comparing traditional reaming with a one-step reamer-irrigator-aspirator reaming system: an experimental study in pigs.
Husebye EE; Lyberg T; Opdahl H; Laurvik H; Røise O
J Trauma; 2010 Oct; 69(4):E6-14. PubMed ID: 20489666
[TBL] [Abstract][Full Text] [Related]
7. Surgical techniques: how I do it? The Reamer/Irrigator/Aspirator (RIA) system.
Giannoudis PV; Tzioupis C; Green J
Injury; 2009 Nov; 40(11):1231-6. PubMed ID: 19783249
[TBL] [Abstract][Full Text] [Related]
8. Treatment of long bone intramedullary infection using the RIA for removal of infected tissue: indications, method and clinical results.
Zalavras CG; Sirkin M
Injury; 2010 Nov; 41 Suppl 2():S43-7. PubMed ID: 21144927
[TBL] [Abstract][Full Text] [Related]
9. Prospective Randomized Clinical Trial Investigating the Effect of the Reamer-Irrigator-Aspirator on the Volume of Embolic Load and Respiratory Function During Intramedullary Nailing of Femoral Shaft Fractures.
Hall JA; McKee MD; Vicente MR; Morison ZA; Dehghan N; Schemitsch CE; Kreder HJ; Petrisor B; Schemitsch EH
J Orthop Trauma; 2017 Apr; 31(4):200-204. PubMed ID: 28323763
[TBL] [Abstract][Full Text] [Related]
10. Rationale for reduced pressure reaming when stabilizing actual or impending pathological femoral fractures: a review of the literature.
Leddy LR
Injury; 2010 Nov; 41 Suppl 2():S48-50. PubMed ID: 21144928
[TBL] [Abstract][Full Text] [Related]
11. Monitoring and controlling intramedullary pressure increase in long bone instrumentation: a study on sheep.
Smith PN; Leditschke A; McMahon D; Sample RR; Perriman D; Prins A; Brüssel T; Li RW
J Orthop Res; 2008 Oct; 26(10):1327-33. PubMed ID: 18464262
[TBL] [Abstract][Full Text] [Related]
12. Use of the reamer-irrigator-aspirator may reduce tumor dissemination during intramedullary fixation of malignancies.
Cipriano CA; Arvanitis LD; Virkus WW
Orthopedics; 2012 Jan; 35(1):e48-52. PubMed ID: 22229613
[TBL] [Abstract][Full Text] [Related]
13. Rinsing-suction reamer attenuates intramedullary pressure increase and fat intravasation in a sheep model.
Joist A; Schult M; Ortmann C; Frerichmann U; Frebel T; Spiegel HU; Kröpfl A; Redl H
J Trauma; 2004 Jul; 57(1):146-51. PubMed ID: 15284565
[TBL] [Abstract][Full Text] [Related]
14. Fat extravasation due to unreamed and experimentally reamed intramedullary nailing of the sheep femur.
Högel F; Kamer L; Schlegel U; Rahn B; Südkamp NP; Müller CA
Injury; 2009 Jul; 40(7):718-21. PubMed ID: 19329114
[TBL] [Abstract][Full Text] [Related]
15. Intramedullary pressure increase and increase in cortical temperature during reaming of the femoral medullary cavity: the effect of draining the medullary contents before reaming.
Mueller CA; Rahn BA
J Trauma; 2003 Sep; 55(3):495-503; discussion 503. PubMed ID: 14501893
[TBL] [Abstract][Full Text] [Related]
16. [A new irrigation-suction boring system facilities low-pressure intramedullary boring of isolated swine femurs].
Joist A; Schult M; Frerichmann U; Frebel T; Spiegel HU; Koppe M; Joosten U
Unfallchirurg; 2003 Oct; 106(10):874-80. PubMed ID: 14652731
[TBL] [Abstract][Full Text] [Related]
17. Coagulation, fibrinolysis and cytokine responses to intramedullary nailing of the femur: an experimental study in pigs comparing traditional reaming and reaming with a one-step reamer-irrigator-aspirator system.
Husebye EE; Opdahl H; Røise O; Aspelin T; Lyberg T
Injury; 2011 Jul; 42(7):630-7. PubMed ID: 20650454
[TBL] [Abstract][Full Text] [Related]
18. [Systemic complications in intramedullary nailing].
Wenda K; Runkel M
Orthopade; 1996 Jun; 25(3):292-9. PubMed ID: 8766666
[TBL] [Abstract][Full Text] [Related]
19. The physiologic and pathologic effects of the reamer irrigator aspirator on fat embolism outcome: an animal study.
Wang RY; Li R; Zdero R; Bell D; Blankstein M; Schemitsch EH
J Orthop Trauma; 2012 Sep; 26(9):e132-7. PubMed ID: 22377507
[TBL] [Abstract][Full Text] [Related]
20. Protective effects of new femoral reaming techniques (Reamer irrigator aspirator, RIA I and II) on pulmonary function and posttraumatic contusion (CT morphology) - results from a standardized large animal model.
Halvachizadeh S; Teuben M; Lempert M; Kalbas Y; Cesarovic N; Lipiski M; Benninger E; Cinelli P; Pfeifer R; Pape HC
Injury; 2021 Jan; 52(1):26-31. PubMed ID: 33046248
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]