164 related articles for article (PubMed ID: 21145554)
1. Peak capacity optimization in comprehensive two dimensional liquid chromatography: a practical approach.
Gu H; Huang Y; Carr PW
J Chromatogr A; 2011 Jan; 1218(1):64-73. PubMed ID: 21145554
[TBL] [Abstract][Full Text] [Related]
2. Simulation of elution profiles in liquid chromatography - II: Investigation of injection volume overload under gradient elution conditions applied to second dimension separations in two-dimensional liquid chromatography.
Stoll DR; Sajulga RW; Voigt BN; Larson EJ; Jeong LN; Rutan SC
J Chromatogr A; 2017 Nov; 1523():162-172. PubMed ID: 28747254
[TBL] [Abstract][Full Text] [Related]
3. Generation and limitations of peak capacity in online two-dimensional liquid chromatography.
Horváth K; Fairchild JN; Guiochon G
Anal Chem; 2009 May; 81(10):3879-88. PubMed ID: 19382753
[TBL] [Abstract][Full Text] [Related]
4. Selection of column dimensions and gradient conditions to maximize the peak-production rate in comprehensive off-line two-dimensional liquid chromatography using monolithic columns.
Eeltink S; Dolman S; Vivo-Truyols G; Schoenmakers P; Swart R; Ursem M; Desmet G
Anal Chem; 2010 Aug; 82(16):7015-20. PubMed ID: 20666432
[TBL] [Abstract][Full Text] [Related]
5. Optimizing the peak capacity per unit time in one-dimensional and off-line two-dimensional liquid chromatography for the separation of complex peptide samples.
Eeltink S; Dolman S; Swart R; Ursem M; Schoenmakers PJ
J Chromatogr A; 2009 Oct; 1216(44):7368-74. PubMed ID: 19285679
[TBL] [Abstract][Full Text] [Related]
6. Effects of first dimension eluent composition in two-dimensional liquid chromatography.
Li X; Carr PW
J Chromatogr A; 2011 Apr; 1218(16):2214-21. PubMed ID: 21411103
[TBL] [Abstract][Full Text] [Related]
7. Theoretical and experimental comparison of one dimensional versus on-line comprehensive two dimensional liquid chromatography for optimized sub-hour separations of complex peptide samples.
Sarrut M; Rouvière F; Heinisch S
J Chromatogr A; 2017 May; 1498():183-195. PubMed ID: 28132733
[TBL] [Abstract][Full Text] [Related]
8. Simulation of elution profiles in liquid chromatography-I: Gradient elution conditions, and with mismatched injection and mobile phase solvents.
Jeong LN; Sajulga R; Forte SG; Stoll DR; Rutan SC
J Chromatogr A; 2016 Jul; 1457():41-9. PubMed ID: 27345210
[TBL] [Abstract][Full Text] [Related]
9. The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography.
Potts LW; Stoll DR; Li X; Carr PW
J Chromatogr A; 2010 Sep; 1217(36):5700-9. PubMed ID: 20673902
[TBL] [Abstract][Full Text] [Related]
10. [Fast optimization of stepwise gradient conditions for ternary mobile phase in reversed-phase high performance liquid chromatography].
Shan YC; Zhang YK; Zhao RH
Se Pu; 2002 Jul; 20(4):289-94. PubMed ID: 12541907
[TBL] [Abstract][Full Text] [Related]
11. Programmed elution in comprehensive two-dimensional liquid chromatography.
Jandera P
J Chromatogr A; 2012 Sep; 1255():112-29. PubMed ID: 22443894
[TBL] [Abstract][Full Text] [Related]
12. A graphical method for understanding the kinetics of peak capacity production in gradient elution liquid chromatography.
Wang X; Stoll DR; Carr PW; Schoenmakers PJ
J Chromatogr A; 2006 Sep; 1125(2):177-81. PubMed ID: 16777118
[TBL] [Abstract][Full Text] [Related]
13. Predictive kinetic optimisation of hydrophilic interaction chromatography × reversed phase liquid chromatography separations: Experimental verification and application to phenolic analysis.
Muller M; Tredoux AGJ; de Villiers A
J Chromatogr A; 2018 Oct; 1571():107-120. PubMed ID: 30100525
[TBL] [Abstract][Full Text] [Related]
14. High resolution two-dimensional liquid chromatography coupled with mass spectrometry for robust and sensitive characterization of therapeutic antibodies at the peptide level.
Stoll DR; Lhotka HR; Harmes DC; Madigan B; Hsiao JJ; Staples GO
J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Dec; 1134-1135():121832. PubMed ID: 31790917
[TBL] [Abstract][Full Text] [Related]
15. A study of the re-equilibration of hydrophilic interaction columns with a focus on viability for use in two-dimensional liquid chromatography.
Seidl C; Bell DS; Stoll DR
J Chromatogr A; 2019 Oct; 1604():460484. PubMed ID: 31488293
[TBL] [Abstract][Full Text] [Related]
16. Peak capacity in gradient reversed-phase liquid chromatography of biopolymers. Theoretical and practical implications for the separation of oligonucleotides.
Gilar M; Neue UD
J Chromatogr A; 2007 Oct; 1169(1-2):139-50. PubMed ID: 17897658
[TBL] [Abstract][Full Text] [Related]
17. Columns and optimum gradient conditions for fast second-dimension separations in comprehensive two-dimensional liquid chromatography.
Hájek T; Jandera P
J Sep Sci; 2012 Jul; 35(14):1712-22. PubMed ID: 22807355
[TBL] [Abstract][Full Text] [Related]
18. Closed form approximations to predict retention times and peak widths in gradient elution under conditions of sample volume overload and sample solvent mismatch.
Rutan SC; Jeong LN; Carr PW; Stoll DR; Weber SG
J Chromatogr A; 2021 Sep; 1653():462376. PubMed ID: 34293516
[TBL] [Abstract][Full Text] [Related]
19. Effects of the gradient profile, sample volume and solvent on the separation in very fast gradients, with special attention to the second-dimension gradient in comprehensive two-dimensional liquid chromatography.
Jandera P; Hájek T; Cesla P
J Chromatogr A; 2011 Apr; 1218(15):1995-2006. PubMed ID: 21081232
[TBL] [Abstract][Full Text] [Related]
20. Optimization of separation in two-dimensional high-performance liquid chromatography by adjusting phase system selectivity and using programmed elution techniques.
Jandera P; Cesla P; Hájek T; Vohralík G; Vynuchalová K; Fischer J
J Chromatogr A; 2008 May; 1189(1-2):207-20. PubMed ID: 18067903
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]