BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 21146438)

  • 1. Design of a complex bioimpedance spectrometer using DFT and undersampling for neural networks diagnostics.
    do Amaral CE; Lopes HS; Arruda LV; Hara MS; Gonçalves AJ; Dias AA
    Med Eng Phys; 2011 Apr; 33(3):356-61. PubMed ID: 21146438
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multi-frequency simultaneous measurement of bioimpedance spectroscopy based on a low crest factor multisine excitation.
    Yang Y; Zhang F; Tao K; Wang L; Wen H; Teng Z
    Physiol Meas; 2015 Mar; 36(3):489-501. PubMed ID: 25679488
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of (reversible) myocardial ischemic injury by means of electrical bioimpedance.
    Mellert F; Winkler K; Schneider C; Dudykevych T; Welz A; Osypka M; Gersing E; Preusse CJ
    IEEE Trans Biomed Eng; 2011 Jun; 58(6):1511-8. PubMed ID: 20595084
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.
    Jaffrin MY; Morel H
    Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bioimpedance Assessment of Oral Squamous Cell Carcinoma with Clinicopathological Correlation.
    Sarode GS; Sarode SC; Kulkarni M; Karmarkar S; Patll S; Auciustine D
    J Contemp Dent Pract; 2015 Sep; 16(9):715-22. PubMed ID: 26522596
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and preliminary evaluation of a portable device for the measurement of bioimpedance spectroscopy.
    Yang Y; Wang J; Yu G; Niu F; He P
    Physiol Meas; 2006 Dec; 27(12):1293-310. PubMed ID: 17135701
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of basal cell carcinoma using electrical impedance and neural networks.
    Dua R; Beetner DG; Stoecker WV; Wunsch DC
    IEEE Trans Biomed Eng; 2004 Jan; 51(1):66-71. PubMed ID: 14723495
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reliability and variability of bioimpedance measures in normal adults: effects of age, gender, and body mass.
    Dittmar M
    Am J Phys Anthropol; 2003 Dec; 122(4):361-70. PubMed ID: 14614757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design and evaluation of a fast Fourier transform-based nonlinear dielectric spectrometer.
    Treo EF; Felice CJ
    Rev Sci Instrum; 2009 Nov; 80(11):114301. PubMed ID: 19947741
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Novel approach of processing electrical bioimpedance data using differential impedance analysis.
    Sanchez B; Bandarenka AS; Vandersteen G; Schoukens J; Bragos R
    Med Eng Phys; 2013 Sep; 35(9):1349-57. PubMed ID: 23601379
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A high accuracy broadband measurement system for time resolved complex bioimpedance measurements.
    Kaufmann S; Malhotra A; Ardelt G; Ryschka M
    Physiol Meas; 2014 Jun; 35(6):1163-80. PubMed ID: 24845882
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design and validation of a multi-electrode bioimpedance system for enhancing spatial resolution of cellular impedance studies.
    Alexander FA; Celestin M; Price DT; Nanjundan M; Bhansali S
    Analyst; 2013 Jul; 138(13):3728-34. PubMed ID: 23689543
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The clinical role of extracellular bioimpedance tomography (Gastro-Mida(x)) in the diagnosis of colorectal diseases.
    Gatta L;
    Minerva Med; 2004 Dec; 95(6):541-56. PubMed ID: 15785439
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of multiple frequency bioelectrical impedance and Cole-Cole analysis for the assessment of body water volumes in healthy humans.
    Cornish BH; Ward LC; Thomas BJ; Jebb SA; Elia M
    Eur J Clin Nutr; 1996 Mar; 50(3):159-64. PubMed ID: 8654329
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Body composition modeling in the calf using an equivalent circuit model of multi-frequency bioimpedance analysis.
    Zhu F; Leonard EF; Levin NW
    Physiol Meas; 2005 Apr; 26(2):S133-43. PubMed ID: 15798226
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Front end with offset-free symmetrical current source optimized for time domain impedance spectroscopy.
    Pliquett U; Schönfeldt M; Barthel A; Frense D; Nacke T; Beckmann D
    Physiol Meas; 2011 Jul; 32(7):927-44. PubMed ID: 21646715
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a foot-to-foot impedance meter measuring extracellular fluid volume in addition to fat-free mass and fat tissue mass.
    Jaffrin MY; Kieffer R; Moreno MV
    Nutrition; 2005; 21(7-8):815-24. PubMed ID: 15975489
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Resolution of binary mixtures of microorganisms using electrochemical impedance spectroscopy and artificial neural networks.
    Muñoz-Berbel X; Vigués N; Mas J; Del Valle M; Muñoz FJ; Cortina-Puig M
    Biosens Bioelectron; 2008 Dec; 24(4):964-8. PubMed ID: 18783936
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantification of the heterogeneity in breast cancer cell lines using whole-cell impedance spectroscopy.
    Han A; Yang L; Frazier AB
    Clin Cancer Res; 2007 Jan; 13(1):139-43. PubMed ID: 17200348
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of algorithms for calculating bioimpedance phase angle values from measured whole-body impedance modulus.
    Nordbotten BJ; Tronstad C; Martinsen Ø; Grimnes S
    Physiol Meas; 2011 Jul; 32(7):755-65. PubMed ID: 21646707
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.