  • 1. Assist device malfunction due to kinking of cannula between heart and chest wall.
    Kato TS; Oda N; Hashimoto S; Ikeda Y; Ishibashi-Ueda H; Komamura K
    Asian Cardiovasc Thorac Ann; 2010 Dec; 18(6):598. PubMed ID: 21149415
    [No Abstract]   [Full Text] [Related]  

  • 2. Interventional Occlusion of Left Ventricular Assist Device Outflow Graft After Pump Thrombosis and Partial Myocardial Recovery.
    Erkilet G; Westenfeld R; Saeed D
    Artif Organs; 2015 Aug; 39(8):729-30. PubMed ID: 26234453
    [No Abstract]   [Full Text] [Related]  

  • 3. Left ventricular assist device outflow cannula obstruction treated with percutaneous endovascular stenting.
    Abraham J; Remick JD; Caulfield T; Puhlman M; Evenson K; Ott G; Kirker E
    Circ Heart Fail; 2015 Jan; 8(1):229-30. PubMed ID: 25605641
    [No Abstract]   [Full Text] [Related]  

  • 4. Novel application of Angiojet rheolytic thrombectomy for massive thrombosis of the native aortic valve and Jarvick 2000 ventricular assist device in a patient with end-stage heart failure.
    Barbieri A; Bertelli L; Sangiorgi GM
    Catheter Cardiovasc Interv; 2011 Nov; 78(6):958-61. PubMed ID: 21805566
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The first successful use of the Levitronix PediMag ventricular support device as a biventricular bridge to transplant in an infant.
    Gerrah R; Charette K; Chen JM
    J Thorac Cardiovasc Surg; 2011 Nov; 142(5):1282-3. PubMed ID: 21529849
    [No Abstract]   [Full Text] [Related]  

  • 6. Implantation of left ventricular assist device complicated by undiagnosed thrombophilia.
    Szarszoi O; Maly J; Turek D; Urban M; Skalsky I; Riha H; Maluskova J; Pirk J; Netuka I
    Tex Heart Inst J; 2012; 39(5):615-7. PubMed ID: 23109751
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetic field interaction between a left ventricular assist device controller and a cardiac resynchronization therapy-defibrillator.
    Meyer M; Steffel J
    Europace; 2015 Nov; 17(11):1719. PubMed ID: 26589903
    [No Abstract]   [Full Text] [Related]  

  • 8. Heartmate XVE destination therapy for end-stage heart failure in a patient with human immunodeficiency virus.
    Mehmood S; Blais D; Martin S; Sai-Sudhakar C
    Interact Cardiovasc Thorac Surg; 2009 Nov; 9(5):909-10. PubMed ID: 19671583
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Left ventricular assist device placement in a patient with end-stage heart failure and human immunodeficiency virus.
    Fieno DS; Czer LS; Schwarz ER; Simsir S
    Interact Cardiovasc Thorac Surg; 2009 Nov; 9(5):919-20. PubMed ID: 19706718
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Left ventricular-assist device arrest: total thrombosis of a continuous flow left ventricular-assist device.
    Missov E
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):115. PubMed ID: 26538194
    [No Abstract]   [Full Text] [Related]  

  • 11. Failed repeated thrombolysis requiring left ventricular assist device pump exchange.
    Tang GH; Kim MC; Pinney SP; Anyanwu AC
    Catheter Cardiovasc Interv; 2013 May; 81(6):1072-4. PubMed ID: 22718366
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of Rotaflow pump for left ventricular assist device bridging for 15 weeks.
    Khaliel F; Al Habeeb W; Saad E; Kjellman U
    Asian Cardiovasc Thorac Ann; 2014 Feb; 22(2):205-7. PubMed ID: 24585796
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thrombolysis for suspected intrapump thrombosis in patients with continuous flow centrifugal left ventricular assist device.
    Muthiah K; Robson D; Macdonald PS; Keogh AM; Kotlyar E; Granger E; Dhital K; Spratt P; Jansz P; Hayward CS
    Artif Organs; 2013 Mar; 37(3):313-8. PubMed ID: 23373528
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Perigraft seroma mimicking cardiac tamponade after implantation of Berlin Heart EXCOR device in an infant.
    Gandolfo F; Brancaccio G; Secinaro A; Amodeo A
    J Thorac Cardiovasc Surg; 2013 Jan; 145(1):e3-4. PubMed ID: 23058664
    [No Abstract]   [Full Text] [Related]  

  • 15. Echocardiography can be more sensitive than thoracic computed tomography in detecting a thrombus in the inflow cannula of a continuous left ventricular assist device.
    Aissaoui N; Paluszkiewicz L; Koertke HH; Morshuis M; Gummert J
    Echocardiography; 2011 Nov; 28(10):E215-6. PubMed ID: 21854442
    [No Abstract]   [Full Text] [Related]  

  • 16. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.
    John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L
    Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Invited commentary.
    Mukherjee R
    Ann Thorac Surg; 2010 Jan; 89(1):137-8. PubMed ID: 20103223
    [No Abstract]   [Full Text] [Related]  

  • 18. Atypical tamponade hemodynamic in a patient with temporary left ventricular assist device.
    Topilsky Y; Price TN; Atchison FW; Joyce LD
    Interact Cardiovasc Thorac Surg; 2011 May; 12(5):832-4. PubMed ID: 21303869
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sudden power loss in a HeartMate II left ventricular assist device due to intermittent pin contact with the battery: case report.
    Belway D; Cleland M; Zakutney T; Grenon J; Mielniczuk LM; Hendry PJ
    ASAIO J; 2013; 59(3):317-9. PubMed ID: 23644621
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The impact of bridge-to-transplant ventricular assist device support on survival after cardiac transplantation.
    Bull DA; Reid BB; Selzman CH; Mesley R; Drakos S; Clayson S; Stoddard G; Gilbert E; Stehlik J; Bader F; Kfoury A; Budge D; Eckels DD; Fuller A; Renlund D; Patel AN
    J Thorac Cardiovasc Surg; 2010 Jul; 140(1):169-73. PubMed ID: 20451930
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.