These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 21157535)

  • 1. Electronic tissue compensation achieved with both dynamic and static multileaf collimator in eclipse treatment planning system for Clinac 6 EX and 2100 CD Varian linear accelerators: Feasibility and dosimetric study.
    Kinhikar RA; Sharma PK; Patkar S; Tambe CM; Deshpande DD
    J Med Phys; 2007 Apr; 32(2):56-9. PubMed ID: 21157535
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric, mechanical, and geometric verification of conformal dynamic arc treatment.
    Malatesta T; Landoni V; delle Canne S; Bufacchi A; Marmiroli L; Caspiani O; Bonanni A; Tortoreto F; Leone MV; Capparella R; Fragomeni R; Begnozzi L
    J Appl Clin Med Phys; 2003; 4(3):195-203. PubMed ID: 12841789
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system.
    MacKenzie MA; Lachaine M; Murray B; Fallone BG; Robinson D; Field GC
    J Appl Clin Med Phys; 2002; 3(2):97-109. PubMed ID: 11958650
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric verification of a commercial 3D treatment planning system for conformal radiotherapy with a dynamic multileaf collimator.
    Pignoli E; Serretiello S; Somigliana A; Zonca G; Pellegrini R; Mongioj V; Marchesini R
    Phys Med Biol; 2000 Aug; 45(8):N77-84. PubMed ID: 10958205
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intensity modulated radiotherapy dosimetry with ion chambers, TLD, MOSFET and EDR2 film.
    Kinhikar RA; Upreti R; Sharma S; Tambe CM; Deshpande DD
    Australas Phys Eng Sci Med; 2007 Mar; 30(1):25-32. PubMed ID: 17508598
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Treatment verification in the presence of inhomogeneities using EPID-based three-dimensional dose reconstruction.
    van Elmpt WJ; Nijsten SM; Dekker AL; Mijnheer BJ; Lambin P
    Med Phys; 2007 Jul; 34(7):2816-26. PubMed ID: 17821989
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mantle fields in the era of dynamic multileaf collimation: field shaping and electronic tissue compensation.
    Davis QG; Paulino AC; Miller R; Ting JY
    Med Dosim; 2006; 31(3):179-83. PubMed ID: 16905447
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Static versus dynamic intensity-modulated radiotherapy: Profile of integral dose in carcinoma of the nasopharynx.
    Jothybasu KS; Bahl A; Subramani V; Rath GK; Sharma DN; Julka PK
    J Med Phys; 2009 Apr; 34(2):66-72. PubMed ID: 20098539
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device.
    Pasma KL; Dirkx ML; Kroonwijk M; Visser AG; Heijmen BJ
    Med Phys; 1999 Nov; 26(11):2373-8. PubMed ID: 10587219
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate.
    Burman C; Chui CS; Kutcher G; Leibel S; Zelefsky M; LoSasso T; Spirou S; Wu Q; Yang J; Stein J; Mohan R; Fuks Z; Ling CC
    Int J Radiat Oncol Biol Phys; 1997 Nov; 39(4):863-73. PubMed ID: 9369136
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional conformal vs. intensity-modulated radiotherapy in head-and-neck cancer patients: comparative analysis of dosimetric and technical parameters.
    Cozzi L; Fogliata A; Bolsi A; Nicolini G; Bernier J
    Int J Radiat Oncol Biol Phys; 2004 Feb; 58(2):617-24. PubMed ID: 14751535
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields.
    Van Esch A; Vanstraelen B; Verstraete J; Kutcher G; Huyskens D
    Radiother Oncol; 2001 Aug; 60(2):181-90. PubMed ID: 11439213
    [TBL] [Abstract][Full Text] [Related]  

  • 13. IMRT implementation and patient specific dose verification with film and ion chamber array detectors.
    Sathiyan S; Ravikumar M; Varatharaj C; Supe SS; Keshava SL
    Gulf J Oncolog; 2010 Jul; (8):20-7. PubMed ID: 20601335
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does the fluence map editing in electronic tissue compensator improve dose homogeneity in bilateral field plan of head and neck patients?
    Kinhikar RA
    J Cancer Res Ther; 2008; 4(2):84-7. PubMed ID: 18688124
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effective penumbra and scalloping effect: a dosimetric study in multifield radiotherapy with multileaf collimator for prostate cancer treatment.
    Stasi M; Baiotto B; Palamara F; Gabriele P; Scielzo G
    Tumori; 2001; 87(1):30-5. PubMed ID: 11669555
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric comparison of treatment planning systems in irradiation of breast with tangential fields.
    Cheng CW; Das IJ; Tang W; Chang S; Tsai JS; Ceberg C; De Gaspie B; Singh R; Fein DA; Fowble B
    Int J Radiat Oncol Biol Phys; 1997 Jul; 38(4):835-42. PubMed ID: 9240653
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement-based Monte Carlo dose calculation system for IMRT pretreatment and on-line transit dose verifications.
    Lin MH; Chao TC; Lee CC; Tung CJ; Yeh CY; Hong JH
    Med Phys; 2009 Apr; 36(4):1167-75. PubMed ID: 19472622
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quality assurance of serial tomotherapy for head and neck patient treatments.
    Low DA; Chao KS; Mutic S; Gerber RL; Perez CA; Purdy JA
    Int J Radiat Oncol Biol Phys; 1998 Oct; 42(3):681-92. PubMed ID: 9806530
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience.
    Zhang Y; Le AH; Tian Z; Iqbal Z; Chiu T; Gu X; Pugachev A; Reynolds R; Park YK; Lin MH; Stojadinovic S
    J Appl Clin Med Phys; 2019 Oct; 20(10):33-42. PubMed ID: 31471950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.