These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
222 related articles for article (PubMed ID: 21161075)
1. Evaluation of collagen gel microstructure by scanning electron microscopy. Pogorelov AG; Selezneva II Bull Exp Biol Med; 2010 Dec; 150(1):153-6. PubMed ID: 21161075 [TBL] [Abstract][Full Text] [Related]
2. SEM sample preparation for cells on 3D scaffolds by freeze-drying and HMDS. Lee JT; Chow KL Scanning; 2012; 34(1):12-25. PubMed ID: 22532079 [TBL] [Abstract][Full Text] [Related]
3. Critical-point drying versus freeze drying for scanning electron microscopy: a quantitative and qualitative study on isolated hepatocytes. Nordestgaard BG; Rostgaard J J Microsc; 1985 Feb; 137(Pt 2):189-207. PubMed ID: 3989858 [TBL] [Abstract][Full Text] [Related]
4. Cryosputtering--a combined freeze-drying and sputtering method for high-resolution electron microscopy. Lindroth M; Fredriksson BA; Bell PB J Microsc; 1991 Feb; 161(Pt 2):229-39. PubMed ID: 2038032 [TBL] [Abstract][Full Text] [Related]
5. [CYTOCOMPATIBILITY AND PREPARATION OF BONE TISSUE ENGINEERING SCAFFOLD BY COMBINING LOW TEMPERATURE THREE DIMENSIONAL PRINTING AND VACUUM FREEZE-DRYING TECHNIQUES]. Li D; Zhang Z; Zheng C; Zhao B; Sun K; Nian Z; Zhang X; Li R; Li H Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Mar; 30(3):292-7. PubMed ID: 27281872 [TBL] [Abstract][Full Text] [Related]
6. Comparison of three-dimensional printing and vacuum freeze-dried techniques for fabricating composite scaffolds. Sun K; Li R; Jiang W; Sun Y; Li H Biochem Biophys Res Commun; 2016 Sep; 477(4):1085-1091. PubMed ID: 27404126 [TBL] [Abstract][Full Text] [Related]
7. A new drying method of biological specimens for scanning electron microscopy: the t-butyl alcohol freeze-drying method. Inoué T; Osatake H Arch Histol Cytol; 1988 Mar; 51(1):53-9. PubMed ID: 3137948 [TBL] [Abstract][Full Text] [Related]
8. Fixation and drying protocols for the preparation of cell samples for time-of-flight secondary ion mass spectrometry analysis. Malm J; Giannaras D; Riehle MO; Gadegaard N; Sjövall P Anal Chem; 2009 Sep; 81(17):7197-205. PubMed ID: 19639962 [TBL] [Abstract][Full Text] [Related]
9. Dynamical in-situ observation of the lyophilization and vacuum-drying processes of a model biopharmaceutical system by an environmental scanning electron microscope. Vetráková Ľ; Neděla V; Runštuk J; Tihlaříková E; Heger D; Shalaev E Int J Pharm; 2020 Jul; 585():119448. PubMed ID: 32461002 [TBL] [Abstract][Full Text] [Related]
10. Freeze-drying from tertiary butanol in the preparation of endocardium for scanning electron microscopy. Wheeler EE; Gavin JB; Seelye RN Stain Technol; 1975 Sep; 50(5):331-7. PubMed ID: 1209660 [TBL] [Abstract][Full Text] [Related]
11. Specimen preparation of the human cerebellar cortex for scanning electron microscopy using a t-butyl alcohol freeze-drying device. Hojo T Scanning Microsc Suppl; 1996; 10():345-8. PubMed ID: 9601551 [TBL] [Abstract][Full Text] [Related]
12. Scanning electron microscopy of freeze-dried aortic elastin. Grut W; Edwards J; Evans EJ J Microsc; 1977 Aug; 110(3):271-5. PubMed ID: 592359 [TBL] [Abstract][Full Text] [Related]
13. Essential Methods of Plant Sample Preparation for High-Resolution Scanning Electron Microscopy at Room Temperature. Nebesářová J Methods Mol Biol; 2019; 1992():63-76. PubMed ID: 31148031 [TBL] [Abstract][Full Text] [Related]
14. Comparing different methods to fix and to dehydrate cells on alginate hydrogel scaffolds using scanning electron microscopy. Santana BP; Nedel F; Perelló Ferrúa C; Marques e Silva R; da Silva AF; Demarco FF; Lenin Villarreal Carreño N Microsc Res Tech; 2015 Jul; 78(7):553-61. PubMed ID: 25871651 [TBL] [Abstract][Full Text] [Related]
15. Care during freeze-drying of bovine pericardium tissue to be used as a biomaterial: a comparative study. Polak R; Pitombo RN Cryobiology; 2011 Oct; 63(2):61-6. PubMed ID: 21619875 [TBL] [Abstract][Full Text] [Related]
16. Ice crystal damage in freeze-dried articular cartilage studied by scanning electron microscopy. Draenert Y; Draenert K Scan Electron Microsc; 1982; (Pt 4):1799-804. PubMed ID: 7184152 [TBL] [Abstract][Full Text] [Related]
17. Conductive coatings studied on inflated lung in the frozen-hydrated and freeze-dried states. Hook G; Lai C; Bastacky J; Hayes T Scan Electron Microsc; 1980; (4):27-32. PubMed ID: 7256208 [TBL] [Abstract][Full Text] [Related]
18. Direct observation of t-butyl alcohol frozen and sublimated samples using low-vacuum scanning electron microscopy. Hashizume H; Itoh S; Tanaka K; Ushiki T Arch Histol Cytol; 1998 May; 61(2):93-8. PubMed ID: 9650884 [TBL] [Abstract][Full Text] [Related]
19. [The preparation of collagen sponge as tissue engineering scaffolds and analysis of its pore structure]. Qin S; Chen H; Yang X; Ye C; Kang N; Tan J; Dai L Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Aug; 27(4):820-4. PubMed ID: 20842852 [TBL] [Abstract][Full Text] [Related]
20. Application of lyophilization to prepare the nitrifying bacterial biofilm for imaging with scanning electron microscopy. Karcz J; Bernas T; Nowak A; Talik E; Woznica A Scanning; 2012; 34(1):26-36. PubMed ID: 21866557 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]