These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
176 related articles for article (PubMed ID: 21167315)
1. Nonfluoroscopic imaging systems reduce radiation exposure in children undergoing ablation of supraventricular tachycardia. Miyake CY; Mah DY; Atallah J; Oikle HP; Melgar ML; Alexander ME; Berul CI; Cecchin F; Walsh EP; Triedman JK Heart Rhythm; 2011 Apr; 8(4):519-25. PubMed ID: 21167315 [TBL] [Abstract][Full Text] [Related]
2. The use of an integrated electroanatomic mapping system and intracardiac echocardiography to reduce radiation exposure in children and young adults undergoing ablation of supraventricular tachycardia. Mah DY; Miyake CY; Sherwin ED; Walsh A; Anderson MJ; Western K; Abrams DJ; Alexander ME; Cecchin F; Walsh EP; Triedman JK Europace; 2014 Feb; 16(2):277-83. PubMed ID: 23928735 [TBL] [Abstract][Full Text] [Related]
3. Nonfluoroscopic catheter navigation for radiofrequency catheter ablation of supraventricular tachycardia in children. Papagiannis J; Tsoutsinos A; Kirvassilis G; Sofianidou I; Koussi T; Laskari C; Kiaffas M; Apostolopoulou S; Rammos S Pacing Clin Electrophysiol; 2006 Sep; 29(9):971-8. PubMed ID: 16981921 [TBL] [Abstract][Full Text] [Related]
4. Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure. See J; Amora JL; Lee S; Lim P; Teo WS; Tan BY; Ho KL; Lee CW; Ching CK Singapore Med J; 2016 Jul; 57(7):390-5. PubMed ID: 26805664 [TBL] [Abstract][Full Text] [Related]
5. Consequence of use of lower dose flat plate fluoroscopy in pediatric patients undergoing ablation for supraventricular tachycardia. Spar DS; Anderson JB; Lemen L; Czosek RJ; Knilans TK Am J Cardiol; 2013 Jul; 112(1):85-9. PubMed ID: 23601578 [TBL] [Abstract][Full Text] [Related]
6. Reducing patient radiation dosage during pediatric SVT ablations using an "ALARA" radiation reduction protocol in the modern fluoroscopic era. Gellis LA; Ceresnak SR; Gates GJ; Nappo L; Pass RH Pacing Clin Electrophysiol; 2013 Jun; 36(6):688-94. PubMed ID: 23510152 [TBL] [Abstract][Full Text] [Related]
7. Contact force-controlled zero-fluoroscopy catheter ablation of right-sided and left atrial arrhythmia substrates. Kerst G; Weig HJ; Weretka S; Seizer P; Hofbeck M; Gawaz M; Schreieck J Heart Rhythm; 2012 May; 9(5):709-14. PubMed ID: 22222276 [TBL] [Abstract][Full Text] [Related]
8. Feasibility of implementation of a "simplified, No-X-Ray, no-lead apron, two-catheter approach" for ablation of supraventricular arrhythmias in children and adults. Stec S; Śledź J; Mazij M; Raś M; Ludwik B; Chrabąszcz M; Śledź A; Banasik M; Bzymek M; Młynarczyk K; Deutsch K; Labus M; Śpikowski J; Szydłowski L J Cardiovasc Electrophysiol; 2014 Aug; 25(8):866-874. PubMed ID: 24654678 [TBL] [Abstract][Full Text] [Related]
9. A nonfluoroscopic approach for electrophysiology and catheter ablation procedures using a three-dimensional navigation system. Tuzcu V Pacing Clin Electrophysiol; 2007 Apr; 30(4):519-25. PubMed ID: 17437576 [TBL] [Abstract][Full Text] [Related]
10. [Evaluation of a low dose imaging protocol on radiation exposure reduction in pediatric supraventricular tachycardia ablation procedure]. Wang F; Lu Y; Yuan C; Bai JR; Yang HS; Wu L Zhonghua Er Ke Za Zhi; 2017 Apr; 55(4):272-276. PubMed ID: 28441823 [No Abstract] [Full Text] [Related]
11. Exclusion of fluoroscopy use in catheter ablation procedures: six years of experience at a single center. Fernández-Gómez JM; Moriña-Vázquez P; Morales Edel R; Venegas-Gamero J; Barba-Pichardo R; Carranza MH J Cardiovasc Electrophysiol; 2014 Jun; 25(6):638-44. PubMed ID: 24611978 [TBL] [Abstract][Full Text] [Related]
12. Near-zero x-ray in arrhythmia ablation using a 3-dimensional electroanatomic mapping system: A multicenter experience. Giaccardi M; Del Rosso A; Guarnaccia V; Ballo P; Mascia G; Chiodi L; Colella A Heart Rhythm; 2016 Jan; 13(1):150-6. PubMed ID: 26341606 [TBL] [Abstract][Full Text] [Related]
13. Catheter Ablation of Right-Sided Accessory Pathways in Adults Using the Three-Dimensional Mapping System: A Randomized Comparison to the Conventional Approach. Ma Y; Qiu J; Yang Y; Tang A PLoS One; 2015; 10(6):e0128760. PubMed ID: 26083408 [TBL] [Abstract][Full Text] [Related]
14. Reduction of radiation exposure during atrial fibrillation ablation using a novel fluoroscopy image integrated 3-dimensional electroanatomic mapping system: A prospective, randomized, single-blind, and controlled study. Huo Y; Christoph M; Forkmann M; Pohl M; Mayer J; Salmas J; Sitzy J; Wunderlich C; Piorkowski C; Gaspar T Heart Rhythm; 2015 Sep; 12(9):1945-55. PubMed ID: 26001508 [TBL] [Abstract][Full Text] [Related]
15. Predictors of Zero X-Ray Ablation for Supraventricular Tachycardias in a Nationwide Multicenter Experience. Pani A; Giuseppina B; Bonanno C; Grazia Bongiorni M; Bottoni N; Brambilla R; Ceglia S; Della Bella P; Vito G; Malaspina D; Menardi E; Napoli V; Negroni MS; Ocello S; Orsida D; Pandozi C; Pedretti S; Penela D; Pepi P; Rossi L; Rovaris G; Scopinaro A; Vincenti A; Viola G; Zacà V; Zoppo F; Vergara P Circ Arrhythm Electrophysiol; 2018 Mar; 11(3):e005592. PubMed ID: 29874166 [TBL] [Abstract][Full Text] [Related]
16. Use of 3D Electroanatomical Navigation (CARTO-3) to Minimize or Eliminate Fluoroscopy Use in the Ablation of Pediatric Supraventricular Tachyarrhythmias. Nagaraju L; Menon D; Aziz PF Pacing Clin Electrophysiol; 2016 Jun; 39(6):574-80. PubMed ID: 26873564 [TBL] [Abstract][Full Text] [Related]
17. Incidence of Echocardiographic Abnormalities Following Pediatric SVT Ablation: Comparison of Cases Utilizing Fluoroscopy Alone to Cases with Adjunctive 3D Electroanatomic Mapping. Gartenberg AJ; Pass RH; Ceresnak S; Nappo L; Janson CM Pediatr Cardiol; 2019 Mar; 40(3):497-503. PubMed ID: 30315340 [TBL] [Abstract][Full Text] [Related]
18. Zero-fluoroscopy approach for ablation of supraventricular tachycardia using the Ensite NavX system: a multicenter experience. Chen G; Wang Y; Proietti R; Wang X; Ouyang F; Ma CS; Yu RH; Zhao C; Ma K; Qiu J; Liu Q; Wang DW BMC Cardiovasc Disord; 2020 Feb; 20(1):48. PubMed ID: 32013865 [TBL] [Abstract][Full Text] [Related]
19. AV nodal reentrant tachycardia or AV reentrant tachycardia using a concealed bypass tract-related adverse events. Brembilla-Perrot B; Bénichou M; Brembilla A; Bozec E; Dorlet S; Sellal JM; Olivier A; Manenti V; Villemin T; Beurrier D; Moulin-Zinsch A; De Chillou C; Girerd N Int J Cardiol; 2015 Nov; 199():84-9. PubMed ID: 26188825 [TBL] [Abstract][Full Text] [Related]
20. Reducing patient radiation exposure during paediatric SVT ablations: use of CARTO® 3 in concert with "ALARA" principles profoundly lowers total dose. Pass RH; Gates GG; Gellis LA; Nappo L; Ceresnak SR Cardiol Young; 2015 Jun; 25(5):963-8. PubMed ID: 25155609 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]