150 related articles for article (PubMed ID: 21167461)
1. Minimally invasive intrathoracic esophagogastric anastomosis: circular stapler technique with transoral placement of the anvil.
Nguyen NT; Nguyen XM; Masoomi H
Semin Thorac Cardiovasc Surg; 2010; 22(3):253-5. PubMed ID: 21167461
[No Abstract] [Full Text] [Related]
2. Thoracoscopic construction of an intrathoracic esophagogastric anastomosis using a circular stapler: transoral placement of the anvil.
Nguyen TN; Hinojosa MW; Smith BR; Gray J; Reavis KM
Ann Thorac Surg; 2008 Sep; 86(3):989-92. PubMed ID: 18721597
[TBL] [Abstract][Full Text] [Related]
3. Minimally invasive intrathoracic esophagogastric anastomosis.
Levy RM; Luketich JD
Semin Thorac Cardiovasc Surg; 2010; 22(3):256-8. PubMed ID: 21167462
[No Abstract] [Full Text] [Related]
4. Technique of esophagojejunostomy using transoral placement of the pretilted anvil head after laparoscopic gastrectomy for gastric cancer.
Sakuramoto S; Kikuchi S; Futawatari N; Moriya H; Katada N; Yamashita K; Watanabe M
Surgery; 2010 May; 147(5):742-7. PubMed ID: 19733877
[TBL] [Abstract][Full Text] [Related]
5. Invited commentary. A method for circular stapled esophagogastric anastomosis.
Heitmiller RF
Ann Thorac Surg; 2008 Sep; 86(3):992-3. PubMed ID: 18721598
[No Abstract] [Full Text] [Related]
6. Cervical esophagogastric anastomosis with a new stapler in the surgery of esophageal carcinoma.
Chunwei F; Qingzeng N; Jianliang L; Weiji W
Eur J Cardiothorac Surg; 2005 Aug; 28(2):291-5. PubMed ID: 15949948
[TBL] [Abstract][Full Text] [Related]
7. [A new instrument for insertion of anvil head for circular stapled anastomosis].
Kobayashi M; Takaya S
Kyobu Geka; 2001 Jun; 54(6):485-7. PubMed ID: 11424499
[TBL] [Abstract][Full Text] [Related]
8. Feasibility of a high intrathoracic esophagogastric anastomosis without thoracic access after laparoscopic-assisted transhiatal esophagectomy: a pilot experimental study.
Binţinţan VV; Mehrabi A; Fonouni H; Esmaeilzadeh M; Müller-Stich BP; Funariu G; Ciuce C; Gutt CN
Surg Innov; 2009 Sep; 16(3):228-36. PubMed ID: 19717391
[TBL] [Abstract][Full Text] [Related]
9. [Intrathoracic thoracoscopic anastomosis in minimally invasive oesophageal resection - technical tips].
Böttger T; Müller M; Hermeneit S; Rodehorst A
Zentralbl Chir; 2009 Feb; 134(1):90-3. PubMed ID: 19242889
[TBL] [Abstract][Full Text] [Related]
10. Comparison of manual and mechanical cervical esophagogastric anastomosis after esophageal resection for squamous cell carcinoma: a prospective randomized controlled trial.
Hsu HH; Chen JS; Huang PM; Lee JM; Lee YC
Eur J Cardiothorac Surg; 2004 Jun; 25(6):1097-101. PubMed ID: 15145015
[TBL] [Abstract][Full Text] [Related]
11. [Completely minimally invasive Ivor Lewis esophagectomy: the preliminary experience of circular-stapled anastomosis with the trans-oral anvil].
Li H; Hu B; You B; Miao JB; Fu YL; Chen QR; Wang Y
Zhonghua Wai Ke Za Zhi; 2010 Nov; 48(22):1747-50. PubMed ID: 21211459
[TBL] [Abstract][Full Text] [Related]
12. Esophagogastric anastomosis performed with a stapler: the occurrence of leakage and stricture.
Wong J; Cheung H; Lui R; Fan YW; Smith A; Siu KF
Surgery; 1987 Apr; 101(4):408-15. PubMed ID: 3563886
[TBL] [Abstract][Full Text] [Related]
13. [Esophagogastric anastomosis at the inferior cricoid margin].
Valente M; Tavecchio L; Muscolino G; Alloisio M; Pastorino U; Bedini AV; Cataldo I; Ravasi G
G Chir; 1990 Mar; 11(3):190-2. PubMed ID: 2223501
[TBL] [Abstract][Full Text] [Related]
14. Surgical staplers: a review.
McGuire J; Wright IC; Leverment JN
J R Coll Surg Edinb; 1997 Feb; 42(1):1-9. PubMed ID: 9046134
[TBL] [Abstract][Full Text] [Related]
15. Use of the circular stapler for the cervical esophagogastric anastomosis in retrosternal gastric esophagoplasty.
Sarfati E; Gossot D; Celerier M
J Thorac Cardiovasc Surg; 1991 Apr; 101(4):745-6. PubMed ID: 2008115
[No Abstract] [Full Text] [Related]
16. [Minimally invasive concepts in esophageal surgery--thoracoscopic anastomosis. An animal experiment study].
Marusch F; Koch A; Kluge J; Stöbe R; Eggeling S; Böttger J; Gastinger I
Zentralbl Chir; 1999; 124(1):63-7. PubMed ID: 10091302
[TBL] [Abstract][Full Text] [Related]
17. Use of a circular stapler for Billroth I anastomosis after distal gastrectomy.
Hasukić S; Muratović O; Hasukić I
S Afr J Surg; 2013 Oct; 51(4):144-5. PubMed ID: 24209700
[TBL] [Abstract][Full Text] [Related]
18. An improved technique for a stapled transabdominal esophagojejunostomy.
Guerra JP; Silva MH; dos Santos JG
Am J Surg; 1997 Jul; 174(1):61-2. PubMed ID: 9240954
[TBL] [Abstract][Full Text] [Related]
19. Techniques to simplify esophagogastric circular stapled anastomoses.
Robinson LA; Moulton AL; Fleming WH
J Surg Oncol; 1994 Dec; 57(4):266-9. PubMed ID: 7990483
[TBL] [Abstract][Full Text] [Related]
20. Safety of EEA staplers for anastomosis between upper esophagus and the gastric tube.
Sugimachi K; Ohno S; Maekawa S; Mori M; Kuwano H; Ueo H
J Surg Oncol; 1990 Jan; 43(1):40-4. PubMed ID: 2296196
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]