88 related articles for article (PubMed ID: 2117231)
1. Tissue compensators with use of vinyl lead sheets for head and neck portals on 4-MV x rays.
Jani SK; Pennington EC
Med Phys; 1990; 17(3):481-2. PubMed ID: 2117231
[TBL] [Abstract][Full Text] [Related]
2. Investigation of the relative surface dose from Lipowitz-metal tissue compensators for 24- and 6-MV photon beams.
Cardarelli GA; Rao SN; Cail D
Med Phys; 1991; 18(2):282-7. PubMed ID: 1904529
[TBL] [Abstract][Full Text] [Related]
3. Tissue compensators made of solid water or lead for megavoltage X-ray radiotherapy.
Constantinou C; Harrington JC
Med Dosim; 1989; 14(1):41-7. PubMed ID: 2500947
[TBL] [Abstract][Full Text] [Related]
4. Evaluation and quality control of a commercial 3-D dose compensator system.
Paliwal BR; Podgorsak MB; Harari PM; Haney P; Jursinic PA
Med Dosim; 1994; 19(3):179-85. PubMed ID: 7818759
[TBL] [Abstract][Full Text] [Related]
5. Skin dose near compensating filters in radiotherapy.
Thomas SJ; Bruce G
Phys Med Biol; 1988 Jun; 33(6):703-10. PubMed ID: 3136465
[TBL] [Abstract][Full Text] [Related]
6. Thin lead sheets as tissue compensators for larger field irradiation.
Mandal KP; Baxter DH; Ray P
Int J Radiat Oncol Biol Phys; 1980 Apr; 6(4):513-7. PubMed ID: 6771243
[No Abstract] [Full Text] [Related]
7. A study of effective attenuation coefficient for calculating tissue compensator thickness.
Bagne FR; Samsami N; Hoke SW; Bronn DG
Med Phys; 1990; 17(1):117-21. PubMed ID: 2106610
[TBL] [Abstract][Full Text] [Related]
8. Polyethylene-lead tissue compensators for megavoltage radiotherapy.
Spicka J; Fleury K; Powers W
Med Dosim; 1988 Mar; 13(1):25-7. PubMed ID: 3150930
[TBL] [Abstract][Full Text] [Related]
9. Inclusion of compensator-induced scatter and beam filtration in pencil beam dose calculations.
du Plessis FC; Willemse CA
Med Phys; 2006 Aug; 33(8):2896-904. PubMed ID: 16964866
[TBL] [Abstract][Full Text] [Related]
10. IMRT with compensators for head-and-neck cancers treatment technique, dosimetric accuracy, and practical experiences.
Salz H; Wiezorek T; Scheithauer M; Schwedas M; Beck J; Wendt TG
Strahlenther Onkol; 2005 Oct; 181(10):665-72. PubMed ID: 16220406
[TBL] [Abstract][Full Text] [Related]
11. Investigation on the reduction of electron contamination with a 6-MV x-ray beam.
Parthasaradhi K; Prasad SG; Rao BM; Lee Y; Ruparel R; Garces R
Med Phys; 1989; 16(1):123-5. PubMed ID: 2493564
[TBL] [Abstract][Full Text] [Related]
12. Use of 10 MV spoiled x ray beam for treatment of head and neck tumors.
Kubo H; Russell MD; Wang CC
Int J Radiat Oncol Biol Phys; 1982 Oct; 8(10):1795-8. PubMed ID: 6818189
[TBL] [Abstract][Full Text] [Related]
13. [Evaluation of compensator used in radiation therapy].
Lin FJ; Cheng NT; Chen HH; Chen CS; Hsien WL; Leung WM
Changgeng Yi Xue Za Zhi; 1990 Jun; 13(2):104-17. PubMed ID: 2224603
[TBL] [Abstract][Full Text] [Related]
14. Skin-sparing reduction effects of thermoplastics used for patient immobilization in head and neck radiotherapy.
Fiorino C; Cattaneo GM; Del Vecchio A; Fusca M; Longobardi B; Signorotto P; Calandrino R
Radiother Oncol; 1994 Mar; 30(3):267-70. PubMed ID: 8209011
[TBL] [Abstract][Full Text] [Related]
15. Computer aided design and verification of megavoltage tissue compensators for oblique beams.
Faddegon BA; Pfalzner P
Med Phys; 1988; 15(5):757-62. PubMed ID: 3141758
[TBL] [Abstract][Full Text] [Related]
16. Clinical considerations in the use of missing tissue compensators for head and neck cases.
Sharma SC; Johnson MW
Med Dosim; 1998; 23(4):267-70. PubMed ID: 9863724
[TBL] [Abstract][Full Text] [Related]
17. Surface dose for megavoltage photon beams outside the treatment field.
Starkschall G; St George FJ; Zellmer DL
Med Phys; 1983; 10(6):906-10. PubMed ID: 6419036
[TBL] [Abstract][Full Text] [Related]
18. Granulate of stainless steel as compensator material.
van Santvoort JP; Binnekamp D; Heijmen BJ; Levendag PC
Radiother Oncol; 1995 Jan; 34(1):78-80. PubMed ID: 7792403
[TBL] [Abstract][Full Text] [Related]
19. Magnetic analysis of the radiation components of a 10 MV photon beam.
Ling CC; Schell MC; Rustgi SN
Med Phys; 1982; 9(1):20-6. PubMed ID: 6804768
[TBL] [Abstract][Full Text] [Related]
20. Verification of compensator thicknesses using a fluoroscopic electronic portal imaging device.
Pasma KL; Kroonwijk M; van Dieren EB; Visser AG; Heijmen BJ
Med Phys; 1999 Aug; 26(8):1524-9. PubMed ID: 10501052
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]