These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 21178556)

  • 1. Reference values for noninvasive cardiac output monitoring in children.
    Meyer S; Todd D; Shadboldt B
    Crit Care Med; 2011 Jan; 39(1):226-7; author reply 227-8. PubMed ID: 21178556
    [No Abstract]   [Full Text] [Related]  

  • 2. The normal ranges of cardiovascular parameters in children measured using the Ultrasonic Cardiac Output Monitor.
    Cattermole GN; Leung PY; Mak PS; Chan SS; Graham CA; Rainer TH
    Crit Care Med; 2010 Sep; 38(9):1875-81. PubMed ID: 20562697
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noninvasive monitoring of cardiac output during exercise by inductance cardiography.
    Kaplan V; Bucklar GB; Bloch KE
    Med Sci Sports Exerc; 2003 May; 35(5):747-52. PubMed ID: 12750583
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?
    Perrino AC
    Yale J Biol Med; 1993; 66(5):397-413. PubMed ID: 7825341
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of cardiac output measurement using the CardioQP oesophageal Doppler with cardiac output measurement using thermodilution technique in children during heart catheterisation.
    ; Knirsch W; Kretschmar O; Tomaske M; Stutz K; Nagdyman N; Balmer C; Schmitz A; Berger F; Bauersfeld U; Weiss M
    Anaesthesia; 2008 Aug; 63(8):851-5. PubMed ID: 18557743
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiac output monitoring in newborns.
    de Boode WP
    Early Hum Dev; 2010 Mar; 86(3):143-8. PubMed ID: 20171816
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Arterial pulse wave analysis: An accurate means of determining cardiac output in children.
    Kim JJ; Dreyer WJ; Chang AC; Breinholt JP; Grifka RG
    Pediatr Crit Care Med; 2006 Nov; 7(6):532-5. PubMed ID: 17006382
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Cardiac output monitoring by impedance cardiography in cardiac surgery].
    Shimizu H; Seki S; Mizuguchi A; Tsuchida H; Watanabe H; Namiki A
    Masui; 1990 Apr; 39(4):508-12. PubMed ID: 2362347
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Circulation monitoring of critically ill patients with the Pulse Contour Cardiac Output system].
    Afshari A; Perner A; Bonde J
    Ugeskr Laeger; 2006 May; 168(18):1746-9. PubMed ID: 16729924
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of a new arterial pulse contour-based cardiac output device.
    de Waal EE; Kalkman CJ; Rex S; Buhre WF
    Crit Care Med; 2007 Aug; 35(8):1904-9. PubMed ID: 17581493
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monitoring cardiac output from the radial artery pressure waveform.
    Orme RM; Pigott DW
    Anaesthesia; 2007 Jan; 62(1):90-1; author reply 91. PubMed ID: 17156236
    [No Abstract]   [Full Text] [Related]  

  • 12. Four-terminal impedance monitoring of cardiac output: an elegant clinical application of a classical engineering trick.
    Kroll MW
    Europace; 2010 May; 12(5):616-7. PubMed ID: 20421223
    [No Abstract]   [Full Text] [Related]  

  • 13. [Monitoring of left ventricular function. Description of a new radioisotope technic].
    Santini M; Mango L; Vitali F
    G Ital Cardiol; 1981; 11(12):2199-2204. PubMed ID: 6980802
    [No Abstract]   [Full Text] [Related]  

  • 14. Assessment of the level of sedation in children after cardiac surgery.
    Lamas A; López-Herce J; Sancho L; Mencía S; Carrillo A; Santiago MJ; Martínez V
    Ann Thorac Surg; 2009 Jul; 88(1):144-50. PubMed ID: 19559213
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous noninvasive monitoring of cardiac output with esophageal Doppler ultrasound during cardiac surgery.
    Mark JB; Steinbrook RA; Gugino LD; Maddi R; Hartwell B; Shemin R; DiSesa V; Rida WN
    Anesth Analg; 1986 Oct; 65(10):1013-20. PubMed ID: 3530048
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monitoring in resuscitation: comparison of cardiac output measurement between pulmonary artery catheter and NICO.
    Carretero MJ; Fontanals J; Agustí M; Arguis MJ; Martínez-Ocón J; Ruiz A; Rios J
    Resuscitation; 2010 Apr; 81(4):404-9. PubMed ID: 20083335
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Noninvasive cardiac output monitoring during anaesthesia and surgery in young children using electrical cardiometry: an observational study.
    Falciola V; Donath SM; Roden E; Davidson A; Vutskits L
    Br J Anaesth; 2022 Mar; 128(3):e235-e238. PubMed ID: 35039175
    [No Abstract]   [Full Text] [Related]  

  • 18. [Normal range of indices of noninvasive cardiac output monitor and its clinical significance].
    Sun DJ
    Zhonghua Wai Ke Za Zhi; 1988 Jun; 26(6):329-31, 381. PubMed ID: 3229231
    [No Abstract]   [Full Text] [Related]  

  • 19. Cardiac output monitoring in pediatric patients.
    Nusmeier A; van der Hoeven JG; Lemson J
    Expert Rev Med Devices; 2010 Jul; 7(4):503-17. PubMed ID: 20583887
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Techniques for determining cardiac output in the intensive care unit.
    Mohammed I; Phillips C
    Crit Care Clin; 2010 Apr; 26(2):355-64, table of contents. PubMed ID: 20381725
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.