These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 21178805)

  • 21. The Use of Clinically Measurable Cochlear Parameters in Cochlear Implant Surgery as Indicators for Size, Shape, and Orientation of the Scala Tympani.
    Schurzig D; Timm ME; Majdani O; Lenarz T; Rau TS
    Ear Hear; 2021; 42(4):1034-1041. PubMed ID: 33480625
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An optically-guided cochlear implant sheath for real-time monitoring of electrode insertion into the human cochlea.
    Starovoyt A; Quirk BC; Putzeys T; Kerckhofs G; Nuyts J; Wouters J; McLaughlin RA; Verhaert N
    Sci Rep; 2022 Nov; 12(1):19234. PubMed ID: 36357503
    [TBL] [Abstract][Full Text] [Related]  

  • 23. In vitro modifications of the scala tympani environment and the cochlear implant array surface.
    Kontorinis G; Scheper V; Wissel K; Stöver T; Lenarz T; Paasche G
    Laryngoscope; 2012 Sep; 122(9):2057-63. PubMed ID: 22648595
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Scala tympani cochleostomy II: topography and histology.
    Adunka OF; Radeloff A; Gstoettner WK; Pillsbury HC; Buchman CA
    Laryngoscope; 2007 Dec; 117(12):2195-200. PubMed ID: 17909447
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Combining perimodiolar electrode placement and atraumatic insertion properties in cochlear implantation -- fact or fantasy?
    Adunka OF; Pillsbury HC; Kiefer J
    Acta Otolaryngol; 2006 May; 126(5):475-82. PubMed ID: 16698696
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode arrays.
    Boyer E; Karkas A; Attye A; Lefournier V; Escude B; Schmerber S
    Otol Neurotol; 2015 Mar; 36(3):422-9. PubMed ID: 25575374
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque.
    Shepherd RK; Clark GM; Xu SA; Pyman BC
    Am J Otol; 1995 Mar; 16(2):186-99. PubMed ID: 8572119
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. II: Comparison of Spiral Clarion and HiFocus II electrodes.
    Wardrop P; Whinney D; Rebscher SJ; Luxford W; Leake P
    Hear Res; 2005 May; 203(1-2):68-79. PubMed ID: 15855031
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study.
    Adunka O; Unkelbach MH; Mack M; Hambek M; Gstoettner W; Kiefer J
    Acta Otolaryngol; 2004 Sep; 124(7):807-12. PubMed ID: 15370564
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Three-Dimensional Force Profile During Cochlear Implantation Depends on Individual Geometry and Insertion Trauma.
    Avci E; Nauwelaers T; Hamacher V; Kral A
    Ear Hear; 2017; 38(3):e168-e179. PubMed ID: 28045786
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Validation of minimally invasive, image-guided cochlear implantation using Advanced Bionics, Cochlear, and Medel electrodes in a cadaver model.
    McRackan TR; Balachandran R; Blachon GS; Mitchell JE; Noble JH; Wright CG; Fitzpatrick JM; Dawant BM; Labadie RF
    Int J Comput Assist Radiol Surg; 2013 Nov; 8(6):989-95. PubMed ID: 23633113
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Morphometric Analysis and Linear Measurements of the Scala Tympani and Implications in Cochlear Implant Electrodes.
    Fujiwara RJT; Ishiyama G; Lopez IA; Ishiyama A
    Otol Neurotol; 2023 Jun; 44(5):e343-e349. PubMed ID: 36893208
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Evaluation of an electrode design for the combined electric-acoustic stimulation].
    Adunka O; Kiefer J; Unkelbach MH; Radeloff A; Lehnert T; Gstöttner W
    Laryngorhinootologie; 2004 Oct; 83(10):653-8. PubMed ID: 15476137
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion.
    Greene NT; Mattingly JK; Banakis Hartl RM; Tollin DJ; Cass SP
    Otol Neurotol; 2016 Dec; 37(10):1541-1548. PubMed ID: 27753703
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Does cochleostomy location influence electrode trajectory and intracochlear trauma?
    Zhou L; Friedmann DR; Treaba C; Peng R; Roland JT
    Laryngoscope; 2015 Apr; 125(4):966-71. PubMed ID: 25345671
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Spread of the intracochlear electrical field: Implications for assessing electrode array location in cochlear implantation.
    Söderqvist S; Sivonen V; Koivisto J; Aarnisalo A; Sinkkonen ST
    Hear Res; 2023 Jul; 434():108790. PubMed ID: 37196460
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improving audiologic performance with partial insertion of a compressed array despite intracochlear retention of four electrodes during revision cochlear implant surgery: A case report.
    Côté M; Trudel M; Philippon D; Bussières R
    Cochlear Implants Int; 2015 Jan; 16(1):57-60. PubMed ID: 24950700
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study.
    Mittmann P; Todt I; Ernst A; Rademacher G; Mutze S; Göricke S; Schlamann M; Ramalingam R; Lang S; Christov F; Arweiler-Harbeck D
    Eur Arch Otorhinolaryngol; 2016 Dec; 273(12):4251-4256. PubMed ID: 27351885
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Mechanisms of electrode fold-over in cochlear implant surgery when using a flexible and slim perimodiolar electrode array.
    Ramos-Macias A; R De Miguel A; Falcon-González JC
    Acta Otolaryngol; 2017 Nov; 137(11):1129-1135. PubMed ID: 28784019
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Precurved Cochlear Implants and Tip Foldover: A Cadaveric Imaging Study.
    Trakimas DR; Kozin ED; Ghanad I; Barber SR; Curtin H; Remenschneider AK
    Otolaryngol Head Neck Surg; 2018 Feb; 158(2):343-349. PubMed ID: 29086634
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.