These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 21181133)

  • 1. Real-time electrical impedance-based measurement to distinguish oral cancer cells and non-cancer oral epithelial cells.
    Yang L; Arias LR; Lane TS; Yancey MD; Mamouni J
    Anal Bioanal Chem; 2011 Feb; 399(5):1823-33. PubMed ID: 21181133
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Interdigitated microelectrode-based microchip for electrical impedance spectroscopic study of oral cancer cells.
    Mamouni J; Yang L
    Biomed Microdevices; 2011 Dec; 13(6):1075-88. PubMed ID: 21833766
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-time electrical impedance detection of cellular activities of oral cancer cells.
    Arias LR; Perry CA; Yang L
    Biosens Bioelectron; 2010 Jun; 25(10):2225-31. PubMed ID: 20304624
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Label-free monitoring of cell-based assays: combining impedance analysis with SPR for multiparametric cell profiling.
    Michaelis S; Wegener J; Robelek R
    Biosens Bioelectron; 2013 Nov; 49():63-70. PubMed ID: 23711901
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cell culture monitoring by impedance mapping using a multielectrode scanning impedance spectroscopy system (CellMap).
    Rahman AR; Register J; Vuppala G; Bhansali S
    Physiol Meas; 2008 Jun; 29(6):S227-39. PubMed ID: 18544796
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Real-time and non-invasive impedimetric monitoring of cell proliferation and chemosensitivity in a perfusion 3D cell culture microfluidic chip.
    Lei KF; Wu MH; Hsu CW; Chen YD
    Biosens Bioelectron; 2014 Jan; 51():16-21. PubMed ID: 23920091
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cancer, pre-cancer and normal oral cells distinguished by dielectrophoresis.
    Mulhall HJ; Labeed FH; Kazmi B; Costea DE; Hughes MP; Lewis MP
    Anal Bioanal Chem; 2011 Nov; 401(8):2455-63. PubMed ID: 21877186
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces.
    Wegener J; Keese CR; Giaever I
    Exp Cell Res; 2000 Aug; 259(1):158-66. PubMed ID: 10942588
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Using cell-substrate impedance and live cell imaging to measure real-time changes in cellular adhesion and de-adhesion induced by matrix modification.
    Rees MD; Thomas SR
    J Vis Exp; 2015 Feb; (96):. PubMed ID: 25742053
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cell-Electrode Models for Impedance Analysis of Epithelial and Endothelial Monolayers Cultured on Microelectrodes.
    Chiu WC; Chen WL; Lai YT; Hung YH; Lo CM
    Sensors (Basel); 2024 Jun; 24(13):. PubMed ID: 39000992
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-time characterization of cytotoxicity using single-cell impedance monitoring.
    Asphahani F; Thein M; Wang K; Wood D; Wong SS; Xu J; Zhang M
    Analyst; 2012 Jul; 137(13):3011-9. PubMed ID: 22498491
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hydrogel-based diffusion chip with Electric Cell-substrate Impedance Sensing (ECIS) integration for cell viability assay and drug toxicity screening.
    Tran TB; Cho S; Min J
    Biosens Bioelectron; 2013 Dec; 50():453-9. PubMed ID: 23911660
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays.
    Liu Q; Yu J; Xiao L; Tang JC; Zhang Y; Wang P; Yang M
    Biosens Bioelectron; 2009 Jan; 24(5):1305-10. PubMed ID: 18783935
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wavelet-based multiscale analysis of bioimpedance data measured by electric cell-substrate impedance sensing for classification of cancerous and normal cells.
    Das D; Shiladitya K; Biswas K; Dutta PK; Parekh A; Mandal M; Das S
    Phys Rev E Stat Nonlin Soft Matter Phys; 2015 Dec; 92(6):062702. PubMed ID: 26764722
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterisation of cell adhesion in airway epithelial cell types using electric cell-substrate impedance sensing.
    Heijink IH; Brandenburg SM; Noordhoek JA; Postma DS; Slebos DJ; van Oosterhout AJ
    Eur Respir J; 2010 Apr; 35(4):894-903. PubMed ID: 19741028
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Two-dimensional impedance imaging of cell migration and epithelial stratification.
    Linderholm P; Braschler T; Vannod J; Barrandon Y; Brouard M; Renaud P
    Lab Chip; 2006 Sep; 6(9):1155-62. PubMed ID: 16929394
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An impedance-based cytotoxicity assay for real-time and label-free assessment of T-cell-mediated killing of adherent cells.
    Peper JK; Schuster H; Löffler MW; Schmid-Horch B; Rammensee HG; Stevanović S
    J Immunol Methods; 2014 Mar; 405():192-8. PubMed ID: 24486140
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterizing Esophageal Cancerous Cells at Different Stages Using the Dielectrophoretic Impedance Measurement Method in a Microchip.
    Wang HC; Nguyen NV; Lin RY; Jen CP
    Sensors (Basel); 2017 May; 17(5):. PubMed ID: 28481265
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Combining optical and electrical impedance techniques for quantitative measurement of confluence in MDCK-I cell cultures.
    De Blasio BF; Laane M; Walmann T; Giaever I
    Biotechniques; 2004 Apr; 36(4):650-4, 656, 658 passim. PubMed ID: 15088383
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cell-substrate impedance fluctuations of single amoeboid cells encode cell-shape and adhesion dynamics.
    Leonhardt H; Gerhardt M; Höppner N; Krüger K; Tarantola M; Beta C
    Phys Rev E; 2016 Jan; 93(1):012414. PubMed ID: 26871108
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.