These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 21185458)

  • 1. A method for accurate localisation of EBSD pattern centres.
    Maurice C; Dzieciol K; Fortunier R
    Ultramicroscopy; 2011 Jan; 111(2):140-8. PubMed ID: 21185458
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A 3D Hough transform for indexing EBSD and Kossel patterns.
    Maurice C; Fortunier R
    J Microsc; 2008 Jun; 230(Pt 3):520-9. PubMed ID: 18503678
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessing the precision of strain measurements using electron backscatter diffraction--part 1: detector assessment.
    Britton TB; Jiang J; Clough R; Tarleton E; Kirkland AI; Wilkinson AJ
    Ultramicroscopy; 2013 Dec; 135():126-35. PubMed ID: 24018163
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Practical error estimation in zoom-in and truncated tomography reconstructions.
    Xiao X; De Carlo F; Stock S
    Rev Sci Instrum; 2007 Jun; 78(6):063705. PubMed ID: 17614614
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of pattern centre in EBSD using the moving-screen technique.
    Carpenter DA; Pugh JL; Richardson GD; Mooney LR
    J Microsc; 2007 Sep; 227(Pt 3):246-7. PubMed ID: 17760619
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Towards high accuracy calibration of electron backscatter diffraction systems.
    Mingard K; Day A; Maurice C; Quested P
    Ultramicroscopy; 2011 Apr; 111(5):320-9. PubMed ID: 21396526
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resolution enhancement in digital x-ray imaging.
    Gravel P; Després P; Beaudoin G; de Guise JA
    Phys Med Biol; 2006 May; 51(10):2415-39. PubMed ID: 16675861
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus.
    Figl M; Ede C; Hummel J; Wanschitz F; Ewers R; Bergmann H; Birkfellner W
    IEEE Trans Med Imaging; 2005 Nov; 24(11):1492-9. PubMed ID: 16279085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
    Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
    J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy assessment of elastic strain measurement by EBSD.
    Villert S; Maurice C; Wyon C; Fortunier R
    J Microsc; 2009 Feb; 233(2):290-301. PubMed ID: 19220695
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calibration of a surgical microscope with automated zoom lenses using an active optical tracker.
    García J; Thoranaghatte R; Marti G; Zheng G; Caversaccio M; González Ballester MA
    Int J Med Robot; 2008 Mar; 4(1):87-93. PubMed ID: 18275035
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and reproducibility of a subpixel extended phase correlation method to determine micron level displacements in the heart.
    Kelly DJ; Azeloglu EU; Kochupura PV; Sharma GS; Gaudette GR
    Med Eng Phys; 2007 Jan; 29(1):154-62. PubMed ID: 16531092
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pattern center determination in electron backscatter diffraction microscopy.
    Basinger J; Fullwood D; Kacher J; Adams B
    Microsc Microanal; 2011 Jun; 17(3):330-40. PubMed ID: 21600069
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-resolution elastic strain measurement from electron backscatter diffraction patterns: new levels of sensitivity.
    Wilkinson AJ; Meaden G; Dingley DJ
    Ultramicroscopy; 2006 Mar; 106(4-5):307-13. PubMed ID: 16324788
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-accuracy and robust localization of large control markers for geometric camera calibration.
    Douxchamps D; Chihara K
    IEEE Trans Pattern Anal Mach Intell; 2009 Feb; 31(2):376-83. PubMed ID: 19110502
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simple camera calibration from a single image using five points on two orthogonal 1-D objects.
    Miyagawa I; Arai H; Koike H
    IEEE Trans Image Process; 2010 Jun; 19(6):1528-38. PubMed ID: 20129859
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The cross algorithm for phase-aberration correction in medical ultrasound images formed with two-dimensional arrays.
    Li Y; Robinson B
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Mar; 55(3):588-601. PubMed ID: 18407849
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Guide-wire tracking during endovascular interventions.
    Baert SA; Viergever MA; Niessen WJ
    IEEE Trans Med Imaging; 2003 Aug; 22(8):965-72. PubMed ID: 12906251
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and optimization of regularized tomographic reconstruction algorithms utilizing equally-sloped tomography.
    Mao Y; Fahimian BP; Osher SJ; Miao J
    IEEE Trans Image Process; 2010 May; 19(5):1259-68. PubMed ID: 20051344
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Camera calibration with one-dimensional objects.
    Zhang Z
    IEEE Trans Pattern Anal Mach Intell; 2004 Jul; 26(7):892-9. PubMed ID: 18579947
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.