These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
73 related articles for article (PubMed ID: 21197489)
1. Heat production during prosthetic preparation of a one-piece dental implant. Gabay E; Cohen O; Machtei EE Int J Oral Maxillofac Implants; 2010; 25(6):1131-6. PubMed ID: 21197489 [TBL] [Abstract][Full Text] [Related]
2. Cooling profile following prosthetic preparation of 1-piece dental implants. Cohen O; Gabay E; Machtei EE J Oral Implantol; 2010; 36(4):273-9. PubMed ID: 20521943 [TBL] [Abstract][Full Text] [Related]
3. Heat transfer to the implant-bone interface during preparation of a zirconia/alumina abutment. Huh JB; Eckert SE; Ko SM; Choi YG Int J Oral Maxillofac Implants; 2009; 24(4):679-83. PubMed ID: 19885408 [TBL] [Abstract][Full Text] [Related]
4. An investigation on heat transfer to the implant-bone interface due to abutment preparation with high-speed cutting instruments. Gross M; Laufer BZ; Ormianar Z Int J Oral Maxillofac Implants; 1995; 10(2):207-12. PubMed ID: 7744440 [TBL] [Abstract][Full Text] [Related]
5. Temperature changes along a dental implant. Patel Z; Geerts GA Int J Prosthodont; 2011; 24(1):58-63. PubMed ID: 21210006 [TBL] [Abstract][Full Text] [Related]
6. A laboratory procedure for optimal implant abutment preparation. Ozcelik TB; Yilmaz B J Prosthodont; 2009 Aug; 18(6):537-40. PubMed ID: 19500234 [TBL] [Abstract][Full Text] [Related]
7. An investigation of heat transfer to the implant-bone interface related to exothermic heat generation during setting of autopolymerizing acrylic resins applied directly to an implant abutment. Ormianer Z; Laufer BZ; Nissan J; Gross M Int J Oral Maxillofac Implants; 2000; 15(6):837-42. PubMed ID: 11151583 [TBL] [Abstract][Full Text] [Related]
8. Primary stability following abutment preparation of one-piece dental implants. Cohen O; Gabay E; Machtei EE Int J Oral Maxillofac Implants; 2013; 28(2):375-9. PubMed ID: 23527337 [TBL] [Abstract][Full Text] [Related]
10. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants. Hoyer SA; Stanford CM; Buranadham S; Fridrich T; Wagner J; Gratton D J Prosthet Dent; 2001 Jun; 85(6):599-607. PubMed ID: 11404760 [TBL] [Abstract][Full Text] [Related]
11. Developing an optimal emergence profile of the definitive restoration with a modified impression cap technique for ITI solid abutment. Kuo SB; Hong HH; Tsai TP; Shen YF J Prosthet Dent; 2002 Dec; 88(6):646-8. PubMed ID: 12488861 [TBL] [Abstract][Full Text] [Related]
12. Implants and sinus-inlay graft in a 1-stage procedure in severely atrophied maxillae: prosthodontic aspects in a 3-year follow-up study. Smedberg JI; Johansson P; Ekenbäck D; Wannfors D Int J Oral Maxillofac Implants; 2001; 16(5):668-74. PubMed ID: 11669249 [TBL] [Abstract][Full Text] [Related]
13. In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections. Sailer I; Sailer T; Stawarczyk B; Jung RE; Hämmerle CH Int J Oral Maxillofac Implants; 2009; 24(5):850-8. PubMed ID: 19865625 [TBL] [Abstract][Full Text] [Related]
14. Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments. Garine WN; Funkenbusch PD; Ercoli C; Wodenscheck J; Murphy WC Int J Oral Maxillofac Implants; 2007; 22(6):928-38. PubMed ID: 18271374 [TBL] [Abstract][Full Text] [Related]
16. Customized implant abutment copings to achieve biologic, mechanical, and esthetic objectives. Rieder CE Int J Periodontics Restorative Dent; 1996 Feb; 16(1):20-9. PubMed ID: 8631607 [TBL] [Abstract][Full Text] [Related]
17. Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant: influence of abutment design. Cehreli MC; Akça K; Iplikçioğlu H; Sahin S Clin Oral Implants Res; 2004 Aug; 15(4):459-65. PubMed ID: 15248881 [TBL] [Abstract][Full Text] [Related]
18. A classification system to measure the implant-abutment microgap. Kano SC; Binon PP; Curtis DA Int J Oral Maxillofac Implants; 2007; 22(6):879-85. PubMed ID: 18271368 [TBL] [Abstract][Full Text] [Related]
19. Load fatigue performance of implant-ceramic abutment combinations. Nguyen HQ; Tan KB; Nicholls JI Int J Oral Maxillofac Implants; 2009; 24(4):636-46. PubMed ID: 19885403 [TBL] [Abstract][Full Text] [Related]
20. Cyclic loading of implant-supported prostheses: comparison of gaps at the prosthetic-abutment interface when cycled abutments are replaced with as-manufactured abutments. Hecker DM; Eckert SE; Choi YG J Prosthet Dent; 2006 Jan; 95(1):26-32. PubMed ID: 16399272 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]