182 related articles for article (PubMed ID: 21200091)
21. [Dynamic enhanced scanning of the pulmonary nodules with 16-slice spiral CT].
Li XY; Zhang XL; Zhang YZ; Chen B; Whang JP; Shi Z
Nan Fang Yi Ke Da Xue Xue Bao; 2009 Jan; 29(1):133-6. PubMed ID: 19218133
[TBL] [Abstract][Full Text] [Related]
22. Assessment of tumor grade and angiogenesis in colorectal cancer: whole-volume perfusion CT.
Sun H; Xu Y; Yang Q; Wang W
Acad Radiol; 2014 Jun; 21(6):750-7. PubMed ID: 24809317
[TBL] [Abstract][Full Text] [Related]
23. [Mesh structure of two-dimensional tumor microvascular architecture phenotype heterogeneity in non-small cell lung cancer].
Xiong Z; Zhou H; Liu JK; Hu CP; Zhou ML; Xia Y; Zhou JH
Nan Fang Yi Ke Da Xue Xue Bao; 2009 Nov; 29(11):2215-8. PubMed ID: 19923070
[TBL] [Abstract][Full Text] [Related]
24. Assessment of bronchial and pulmonary blood supply in non-small cell lung cancer subtypes using computed tomography perfusion.
Nguyen-Kim TD; Frauenfelder T; Strobel K; Veit-Haibach P; Huellner MW
Invest Radiol; 2015 Mar; 50(3):179-86. PubMed ID: 25500892
[TBL] [Abstract][Full Text] [Related]
25. [MSCT perfusion imaging and its correlation with perfusion parameters, survivin expression, MVD, and pathologic grade in hepatocellular carcinomas].
Long X; Cao J; Shi L; Li W; Liu H
Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2009 Nov; 34(11):1096-102. PubMed ID: 19952399
[TBL] [Abstract][Full Text] [Related]
26. Role of CT perfusion imaging in patients with variously differentiated gastric adenocarcinoma.
Sun ZQ; Cheng XF; Ge YX; Chen L; Yue JG; Jin LF; Xie ZH; Zhang HD; Xuan YH
J Xray Sci Technol; 2015; 23(6):737-44. PubMed ID: 26756409
[TBL] [Abstract][Full Text] [Related]
27. [Perfusion characteristics of normal renal cortex with 64-slice spiral CT].
Sun H; Xue HD; Liu W; Jin ZY; Zhao WM
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2009 Apr; 31(2):232-6. PubMed ID: 19507606
[TBL] [Abstract][Full Text] [Related]
28. [Evaluation of microvessel density and vascular endothelial growth factor in colorectal carcinoma with 64-multidetector-row CT perfusion imaging].
Feng ST; Sun CH; Li ZP; Guo HY; Peng ZP; Huang JW; Meng QF; Zheng KG; Xu DS
Zhonghua Wei Chang Wai Ke Za Zhi; 2008 Nov; 11(6):537-41. PubMed ID: 19031129
[TBL] [Abstract][Full Text] [Related]
29. Whole tumour quantitative measurement of first-pass perfusion of oesophageal squamous cell carcinoma using 64-row multidetector computed tomography: correlation with microvessel density.
Chen TW; Yang ZG; Wang QL; Li Y; Qian LL; Chen HJ
Eur J Radiol; 2011 Aug; 79(2):218-23. PubMed ID: 20399055
[TBL] [Abstract][Full Text] [Related]
30. Correlations between CT perfusion parameters and vascular endothelial growth factor expression and microvessel density in implanted VX2 lung tumors.
Ling S; Deng D; Mo Y; Zhang X; Guan X; Wei Q
Cell Biochem Biophys; 2014 Sep; 70(1):629-33. PubMed ID: 24777810
[TBL] [Abstract][Full Text] [Related]
31. [Combined scores of 64 multi-slice CT perfusion characteristics for evaluating solitary pulmonary nodules].
Xu J; Song W; Jin ZY; Xu Y; Wang Y
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2007 Dec; 29(6):750-4. PubMed ID: 18595252
[TBL] [Abstract][Full Text] [Related]
32. Assessment of tumor vascularity in lung cancer using volume perfusion CT (VPCT) with histopathologic comparison: a further step toward an individualized tumor characterization.
Spira D; Neumeister H; Spira SM; Hetzel J; Spengler W; von Weyhern CH; Horger M
J Comput Assist Tomogr; 2013; 37(1):15-21. PubMed ID: 23321828
[TBL] [Abstract][Full Text] [Related]
33. Diagnostic value of one-stop CT energy spectrum and perfusion for angiogenesis in colon and rectum cancer.
Zhao L; Zhou W; Fu Y; Ge Y; Feng L; Wang X; Li Z; Chen W
BMC Med Imaging; 2024 May; 24(1):116. PubMed ID: 38773384
[TBL] [Abstract][Full Text] [Related]
34. Assessment of 64-slice spiral computed tomography with perfusion weighted imaging in the early diagnosis of ground-glass opacity lung cancer.
Lv Y; Jin Y; Xu D; Yan Q; Liu G; Zhang H; Yuan D; Bao J
J BUON; 2016; 21(4):954-957. PubMed ID: 27685919
[TBL] [Abstract][Full Text] [Related]
35. Evaluation of angiogenesis in colorectal carcinoma with multidetector-row CT multislice perfusion imaging.
Feng ST; Sun CH; Li ZP; Mak HK; Peng ZP; Guo HY; Meng QF
Eur J Radiol; 2010 Aug; 75(2):191-6. PubMed ID: 19481397
[TBL] [Abstract][Full Text] [Related]
36. Computed tomography perfusion imaging of renal cell carcinoma: systematic comparison with histopathological angiogenic and prognostic markers.
Reiner CS; Roessle M; Thiesler T; Eberli D; Klotz E; Frauenfelder T; Sulser T; Moch H; Alkadhi H
Invest Radiol; 2013 Apr; 48(4):183-91. PubMed ID: 23328912
[TBL] [Abstract][Full Text] [Related]
37. Solitary pulmonary nodules: association between signal characteristics in dynamic contrast enhanced MRI and tumor angiogenesis.
Schaefer JF; Schneider V; Vollmar J; Wehrmann M; Aebert H; Friedel G; Vonthein R; Schick F; Claussen CD
Lung Cancer; 2006 Jul; 53(1):39-49. PubMed ID: 16690161
[TBL] [Abstract][Full Text] [Related]
38. [Blood supply of liver metastatic tumors observed by both CT arterial portography via superior mesenterica arterial and multi-slice spiral CT perfusion imaging].
Shi GF; Wang Q; Li ZG; Wang SJ; DU Y; Wang YN
Ai Zheng; 2007 Nov; 26(11):1257-62. PubMed ID: 17991329
[TBL] [Abstract][Full Text] [Related]
39. Feasibility of quantitative parameters of dynamically enhanced patterns of spiral computed tomography scanning integrated into tumour progression before targeted treatment of non-small cell lung cancer.
Qiao PG; Huang Q; Zhou J; Wang XC; Li M; Ma JL; Tian N; Li GJ
J Med Imaging Radiat Oncol; 2015 Apr; 59(2):216-20. PubMed ID: 25597329
[TBL] [Abstract][Full Text] [Related]
40. Esophageal squamous cell carcinoma: assessing tumor angiogenesis using multi-slice CT perfusion imaging.
Song T; Shen YG; Jiao NN; Li XH; Hu HT; Qu JR; Chen XJ; Feng W; Zhang X; Li HL
Dig Dis Sci; 2012 Aug; 57(8):2195-202. PubMed ID: 22476585
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]