These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
301 related articles for article (PubMed ID: 21209481)
21. A novel technique for distal locking of intramedullary nail based on two non-constrained fluoroscopic images and navigation. Leloup T; El Kazzi W; Schuind F; Warzée N IEEE Trans Med Imaging; 2008 Sep; 27(9):1202-12. PubMed ID: 18779062 [TBL] [Abstract][Full Text] [Related]
22. Efficacy of an aiming device for the placement of distal interlocking screws in trochanteric fixation nailing. Boraiah S; Barker JU; Lorich D Arch Orthop Trauma Surg; 2009 Sep; 129(9):1177-82. PubMed ID: 18677491 [TBL] [Abstract][Full Text] [Related]
23. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures. Vallier HA; Cureton BA; Patterson BM J Orthop Trauma; 2011 Dec; 25(12):736-41. PubMed ID: 21904230 [TBL] [Abstract][Full Text] [Related]
24. [Effect of blocking screws on breakage of interlocking intramedullary nails]. Ai J; Li P; Han Y Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2007 Mar; 21(3):282-4. PubMed ID: 17419212 [TBL] [Abstract][Full Text] [Related]
25. Comparison of two kinds of intramedullary nails in the treatment of femoral shaft fractures in adults. Chen W; Wang J; Su YL; Zhagn Q; Wang B; Li ZY; Zhang YZ Chin Med J (Engl); 2011 Dec; 124(23):3900-5. PubMed ID: 22340317 [TBL] [Abstract][Full Text] [Related]
26. [An analysis of failure factors in treatment of femoral shaft fracture with interlocking intramedullary nailing]. Li GH; Li F; Xia RY; Wang TP; Chen AM Zhonghua Wai Ke Za Zhi; 2006 Apr; 44(8):538-40. PubMed ID: 16784632 [TBL] [Abstract][Full Text] [Related]
28. Robust identification and localization of intramedullary nail holes for distal locking using CBCT: a simulation study. Kamarianakis Z; Buliev I; Pallikarakis N Med Eng Phys; 2011 May; 33(4):479-89. PubMed ID: 21183392 [TBL] [Abstract][Full Text] [Related]
29. [Insertion of distal screws in interlocking nailing using a new free-hand control device]. Pennig D; Brug E Unfallchirurg; 1989 Jul; 92(7):331-4. PubMed ID: 2762819 [TBL] [Abstract][Full Text] [Related]
30. The comparison of freehand fluoroscopic guidance and electromagnetic navigation for distal locking of intramedullary implants. Uruc V; Ozden R; Dogramacı Y; Kalacı A; Dikmen B; Yıldız OS; Yengil E Injury; 2013 Jun; 44(6):863-6. PubMed ID: 23298756 [TBL] [Abstract][Full Text] [Related]
31. [Application of auto-control micro-motion intramedullary locking nail in the treatment of femoral shaft fractures]. Zhang H; Liu Y; Gao S; Du Z Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jun; 22(6):696-9. PubMed ID: 18630566 [TBL] [Abstract][Full Text] [Related]
32. The insertion of intramedullary nail locking screws without fluoroscopy: a faster and safer technique. Chan DS; Burris RB; Erdogan M; Sagi HC J Orthop Trauma; 2013 Jul; 27(7):363-6. PubMed ID: 23287748 [TBL] [Abstract][Full Text] [Related]
33. Surgical navigation based on fluoroscopy--clinical application for computer-assisted distal locking of intramedullary implants. Suhm N; Jacob AL; Nolte LP; Regazzoni P; Messmer P Comput Aided Surg; 2000; 5(6):391-400. PubMed ID: 11295852 [TBL] [Abstract][Full Text] [Related]
34. Placement of the distal locking screws of the femoral intramedullary nail without radiation. Steriopoulos KA; Kontakis GM; Katonis PG; Galanakis IA; Dretakis EK Arch Orthop Trauma Surg; 1996; 115(1):43-4. PubMed ID: 8775709 [TBL] [Abstract][Full Text] [Related]
35. Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail. Persiani P; Gurzi M; Moreschini O; Di Giacomo G; Villani C Musculoskelet Surg; 2017 Apr; 101(1):19-23. PubMed ID: 27878549 [TBL] [Abstract][Full Text] [Related]
36. Surgical technique: static intramedullary nailing of the femur and tibia without intraoperative fluoroscopy. White NJ; Sorkin AT; Konopka G; McKinley TO Clin Orthop Relat Res; 2011 Dec; 469(12):3469-76. PubMed ID: 21369767 [TBL] [Abstract][Full Text] [Related]
37. Intramedullary Nail Fixation Assisted by Orthopaedic Robot Navigation for Intertrochanteric Fractures in Elderly Patients. Lan H; Tan Z; Li KN; Gao JH; Liu TH Orthop Surg; 2019 Apr; 11(2):255-262. PubMed ID: 31004410 [TBL] [Abstract][Full Text] [Related]
38. 3D visualized robot assisted reduction of femoral shaft fractures: evaluation in exposed cadaveric bones. Oszwald M; Westphal R; Bredow J; Gaulke R; O'Loughlin PF; Huefner T; Wahl F; Krettek C; Goesling T Technol Health Care; 2009; 17(4):337-43. PubMed ID: 19822949 [TBL] [Abstract][Full Text] [Related]
39. Distal interlocking screw placement in the femur: free-hand versus electromagnetic assisted technique (sureshot). Maqungo S; Horn A; Bernstein B; Keel M; Roche S J Orthop Trauma; 2014 Dec; 28(12):e281-3. PubMed ID: 24714403 [TBL] [Abstract][Full Text] [Related]
40. Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study. Anastopoulos G; Ntagiopoulos PG; Chissas D; Loupasis G; Asimakopoulos A; Athanaselis E; Megas P Injury; 2008 Oct; 39(10):1210-5. PubMed ID: 18703184 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]