These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 21215524)

  • 1. Pulsed-laser atom probe studies of a precipitation hardened maraging TRIP steel.
    Dmitrieva O; Choi P; Gerstl SS; Ponge D; Raabe D
    Ultramicroscopy; 2011 May; 111(6):623-7. PubMed ID: 21215524
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Voltage-pulsed and laser-pulsed atom probe tomography of a multiphase high-strength low-carbon steel.
    Mulholland MD; Seidman DN
    Microsc Microanal; 2011 Dec; 17(6):950-62. PubMed ID: 22030271
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Precipitation evolution in a Ti-free and Ti-containing stainless maraging steel.
    Schober M; Schnitzer R; Leitner H
    Ultramicroscopy; 2009 Apr; 109(5):553-62. PubMed ID: 19100688
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the field evaporation behavior of a model Ni-Al-Cr superalloy studied by picosecond pulsed-laser atom-probe tomography.
    Zhou Y; Booth-Morrison C; Seidman DN
    Microsc Microanal; 2008 Dec; 14(6):571-80. PubMed ID: 18986610
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Nanoscale precipitation in a maraging steel studied by APFIM.
    Stiller K; Hättestrand M
    Microsc Microanal; 2004 Jun; 10(3):342-8. PubMed ID: 15233852
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Overcoming challenges in the study of nitrided microalloyed steels using atom probe.
    Xie KY; Breen AJ; Yao L; Moody MP; Gault B; Cairney JM; Ringer SP
    Ultramicroscopy; 2012 Jan; 112(1):32-8. PubMed ID: 22094413
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigations of field-evaporated end forms in voltage- and laser-pulsed atom probe tomography.
    Shariq A; Mutas S; Wedderhoff K; Klein C; Hortenbach H; Teichert S; Kücher P; Gerstl SS
    Ultramicroscopy; 2009 Apr; 109(5):472-9. PubMed ID: 19062187
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of laser pulsing on the composition measurement of an Al-Mg-Si-Cu alloy using three-dimensional atom probe.
    Sha G; Ringer SP
    Ultramicroscopy; 2009 Apr; 109(5):580-4. PubMed ID: 19070960
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Atom probe tomography investigation of lath boundary segregation and precipitation in a maraging stainless steel.
    Thuvander M; Andersson M; Stiller K
    Ultramicroscopy; 2013 Sep; 132():265-70. PubMed ID: 23234833
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Atom probe tomography of Ni-base superalloys Allvac 718Plus and Alloy 718.
    Viskari L; Stiller K
    Ultramicroscopy; 2011 May; 111(6):652-8. PubMed ID: 21295914
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Some aspects of the field evaporation behaviour of GaSb.
    Müller M; Saxey DW; Smith GD; Gault B
    Ultramicroscopy; 2011 May; 111(6):487-92. PubMed ID: 21159438
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A model Ni-Al-Mo superalloy studied by ultraviolet pulsed-laser-assisted local-electrode atom-probe tomography.
    Tu Y; Plotnikov EY; Seidman DN
    Microsc Microanal; 2015 Apr; 21(2):480-90. PubMed ID: 25776828
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The study of quantitativeness in atom probe analysis of alloying elements in steel.
    Yamaguchi Y; Takahashi J; Kawakami K
    Ultramicroscopy; 2009 Apr; 109(5):541-4. PubMed ID: 19144470
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Atom Probe Tomographic Characterization of Nanoscale Cu-Rich Precipitates in 17-4 Precipitate Hardened Stainless Steel Tempered at Different Temperatures.
    Wang Z; Fang X; Li H; Liu W
    Microsc Microanal; 2017 Apr; 23(2):340-349. PubMed ID: 28300016
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Atom probe tomographic studies of precipitation in Al-0.1Zr-0.1Ti (at.%) alloys.
    Knipling KE; Dunand DC; Seidman DN
    Microsc Microanal; 2007 Dec; 13(6):503-16. PubMed ID: 18001515
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative atom probe analyses of rare-earth-doped ceria by femtosecond pulsed laser.
    Li F; Ohkubo T; Chen YM; Kodzuka M; Hono K
    Ultramicroscopy; 2011 May; 111(6):589-94. PubMed ID: 21190798
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Interpreting atom probe data from chromium oxide scales.
    La Fontaine A; Gault B; Breen A; Stephenson L; Ceguerra AV; Yang L; Nguyen TD; Zhang J; Young DJ; Cairney JM
    Ultramicroscopy; 2015 Dec; 159 Pt 2():354-9. PubMed ID: 25796357
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determining the composition of small features in atom probe: bcc Cu-rich precipitates in an Fe-rich matrix.
    Morley A; Sha G; Hirosawa S; Cerezo A; Smith GD
    Ultramicroscopy; 2009 Apr; 109(5):535-40. PubMed ID: 19028011
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of atom probe analysis parameters on composition measurement of precipitates in an Al-Mg-Si-Cu alloy.
    Jin S; Su H; Qian F; Li Y; Sha G
    Ultramicroscopy; 2022 May; 235():113495. PubMed ID: 35240391
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of compositional and morphological atom-probe tomography analyses for a multicomponent Fe-Cu steel.
    Kolli RP; Seidman DN
    Microsc Microanal; 2007 Aug; 13(4):272-84. PubMed ID: 17637076
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.