These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 21229702)

  • 21. Case report: pulmonary soiling after one-lung ventilation with a bronchial blocker.
    Park HP; Bahk JH; Oh YS; Ham BM
    Can J Anaesth; 2002 Oct; 49(8):874-6. PubMed ID: 12374720
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Right bronchial intubation using a left-sided double-lumen tube in a patient with situs inversus].
    Bougaki M; Orii R; Yamada Y
    Masui; 2007 Dec; 56(12):1411-3. PubMed ID: 18078097
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Randomized clinical trial comparing double-lumen tube and EZ-Blocker for single-lung ventilation.
    Ruetzler K; Grubhofer G; Schmid W; Papp D; Nabecker S; Hutschala D; Lang G; Hager H
    Br J Anaesth; 2011 Jun; 106(6):896-902. PubMed ID: 21493621
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Lung isolation during port-access cardiac surgery: double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker.
    Grocott HP; Darrow TR; Whiteheart DL; Glower DD; Smith MS
    J Cardiothorac Vasc Anesth; 2003 Dec; 17(6):725-7. PubMed ID: 14689413
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers.
    Ghosh S; Klein AA; Prabhu M; Falter F; Arrowsmith JE
    Br J Anaesth; 2008 Sep; 101(3):424-8. PubMed ID: 18556694
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Sequential one-lung ventilation using one Arndt endobronchial blocker in a pediatric patient undergoing bilateral, video-assisted thoracoscopic surgery (VATS).
    Li PY; Gu HH; Liang WM
    J Clin Anesth; 2009 Sep; 21(6):464. PubMed ID: 19833286
    [No Abstract]   [Full Text] [Related]  

  • 27. Devices for lung isolation used by anesthesiologists with limited thoracic experience: comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker.
    Campos JH; Hallam EA; Van Natta T; Kernstine KH
    Anesthesiology; 2006 Feb; 104(2):261-6, discussion 5A. PubMed ID: 16436844
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The Papworth BiVent tube: a new device for lung isolation.
    Ghosh S; Falter F; Goldsmith K; Arrowsmith JE
    Anaesthesia; 2008 Sep; 63(9):996-1000. PubMed ID: 18540927
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Which device should be considered the best for lung isolation: double-lumen endotracheal tube versus bronchial blockers.
    Campos JH
    Curr Opin Anaesthesiol; 2007 Feb; 20(1):27-31. PubMed ID: 17211163
    [TBL] [Abstract][Full Text] [Related]  

  • 30. How clinical experience leads anesthetists in the choice of double-lumen tube size.
    Zani G; Stefano M; Tommaso BF; Marco R; Salvatore B; Antonio C; Vanni A
    J Clin Anesth; 2016 Aug; 32():1-3. PubMed ID: 27290933
    [No Abstract]   [Full Text] [Related]  

  • 31. Usefulness of the WuScope to facilitate double-lumen endotracheal tube placement in a patient with ankylosing spondylitis.
    Yu HD; Ho AC; Wu YC; Lin TS
    Chang Gung Med J; 2011; 34(2):218-23. PubMed ID: 21539765
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Placement of the Univent tube without fiberoptic bronchoscope assistance.
    Weng H; Xu ZY; Liu J; Ma D; Liu DS
    Anesth Analg; 2010 Feb; 110(2):508-14. PubMed ID: 19933530
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Management of one lung ventilation with bronchial blocker catheter for a patient with tracheobronchopathia osteochondroplastica].
    Myojo Y; Kamiutsuri K; Taki Y; Tohyama K; Usukura A
    Masui; 2007 Feb; 56(2):167-8. PubMed ID: 17315731
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Sequential one-lung isolation using a double arndt bronchial blocker technique.
    Culp WC; Kinsky MP
    Anesth Analg; 2004 Sep; 99(3):945-946. PubMed ID: 15333436
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Case report of using a connector (phycon TCB bronchial blocker) for pediatric one-lung anesthesia].
    Terada Y; Matsukawa T; Takahashi K; Sasuga M; Ohkawa I
    Masui; 2007 Mar; 56(3):334-6. PubMed ID: 17366923
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Our experience with the Univent tube].
    Mateo E; GarcĂ­a R; Llagunes J; Rico G; Tommassi M; Granell M; Grau F
    Rev Esp Anestesiol Reanim; 1998 Dec; 45(10):421-4. PubMed ID: 9927833
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Failure to provide adequate one-lung ventilation with a conventional endotracheal tube using a transbronchial approach: a case report.
    Ng YT; Chung PC; Hsieh JR; Yu CC; Lau WM; Liu YH
    Can J Anaesth; 2003; 50(6):603-6. PubMed ID: 12826555
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [The Univent tube: a substitute to double lumen tubes].
    Mercier FJ; Fischler M
    Ann Fr Anesth Reanim; 1994; 13(5):754-8. PubMed ID: 7733530
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Double-lumen endotracheal tube for one-lung ventilation through a fresh tracheostomy stoma: a case report.
    Yaney LL
    AANA J; 2007 Dec; 75(6):411-5. PubMed ID: 18179000
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Difficulty in one-lung ventilation reveals tracheobronchial anomaly].
    Tsuda K; Kinoshita R; Yamada K; Tsubokawa T; Yamamoto K
    Masui; 2006 Jan; 55(1):100-2. PubMed ID: 16440720
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.