These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

277 related articles for article (PubMed ID: 21245524)

  • 41. P300-based brain computer interface: reliability and performance in healthy and paralysed participants.
    Piccione F; Giorgi F; Tonin P; Priftis K; Giove S; Silvoni S; Palmas G; Beverina F
    Clin Neurophysiol; 2006 Mar; 117(3):531-7. PubMed ID: 16458069
    [TBL] [Abstract][Full Text] [Related]  

  • 42. A comparison of recording modalities of P300 event-related potentials (ERP) for brain-computer interface (BCI) paradigm.
    Mayaud L; Congedo M; Van Laghenhove A; Orlikowski D; Figère M; Azabou E; Cheliout-Heraut F
    Neurophysiol Clin; 2013 Oct; 43(4):217-27. PubMed ID: 24094907
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Optimizing the P300-based brain-computer interface: current status, limitations and future directions.
    Mak JN; Arbel Y; Minett JW; McCane LM; Yuksel B; Ryan D; Thompson D; Bianchi L; Erdogmus D
    J Neural Eng; 2011 Apr; 8(2):025003. PubMed ID: 21436525
    [TBL] [Abstract][Full Text] [Related]  

  • 44. An auditory oddball (P300) spelling system for brain-computer interfaces.
    Furdea A; Halder S; Krusienski DJ; Bross D; Nijboer F; Birbaumer N; Kübler A
    Psychophysiology; 2009 May; 46(3):617-25. PubMed ID: 19170946
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Projected accuracy metric for the P300 Speller.
    Colwell K; Throckmorton C; Collins L; Morton K
    IEEE Trans Neural Syst Rehabil Eng; 2014 Sep; 22(5):921-5. PubMed ID: 25203496
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A POMDP approach to optimizing P300 speller BCI paradigm.
    Park J; Kim KE
    IEEE Trans Neural Syst Rehabil Eng; 2012 Jul; 20(4):584-94. PubMed ID: 22510955
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Exogenous and endogenous orienting of visuospatial attention in P300-guided brain computer interfaces: a pilot study on healthy participants.
    Marchetti M; Piccione F; Silvoni S; Priftis K
    Clin Neurophysiol; 2012 Apr; 123(4):774-9. PubMed ID: 21903462
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The MindGame: a P300-based brain-computer interface game.
    Finke A; Lenhardt A; Ritter H
    Neural Netw; 2009 Nov; 22(9):1329-33. PubMed ID: 19635654
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A new P300 stimulus presentation pattern for EEG-based spelling systems.
    Jin J; Horki P; Brunner C; Wang X; Neuper C; Pfurtscheller G
    Biomed Tech (Berl); 2010 Aug; 55(4):203-10. PubMed ID: 20569051
    [TBL] [Abstract][Full Text] [Related]  

  • 50. P300 speller BCI with a mobile EEG system: comparison to a traditional amplifier.
    De Vos M; Kroesen M; Emkes R; Debener S
    J Neural Eng; 2014 Jun; 11(3):036008. PubMed ID: 24763067
    [TBL] [Abstract][Full Text] [Related]  

  • 51. An adaptive P300-based online brain-computer interface.
    Lenhardt A; Kaper M; Ritter HJ
    IEEE Trans Neural Syst Rehabil Eng; 2008 Apr; 16(2):121-30. PubMed ID: 18403280
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Comparison of a row-column speller vs. a novel lateral single-character speller: assessment of BCI for severe motor disabled patients.
    Pires G; Nunes U; Castelo-Branco M
    Clin Neurophysiol; 2012 Jun; 123(6):1168-81. PubMed ID: 22244868
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Single-trial EEG source reconstruction for brain-computer interface.
    Noirhomme Q; Kitney RI; Macq B
    IEEE Trans Biomed Eng; 2008 May; 55(5):1592-601. PubMed ID: 18440905
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Surfing the internet with a BCI mouse.
    Yu T; Li Y; Long J; Gu Z
    J Neural Eng; 2012 Jun; 9(3):036012. PubMed ID: 22626911
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Evaluation of the performances of different P300 based brain-computer interfaces by means of the efficiency metric.
    Quitadamo LR; Abbafati M; Cardarilli GC; Mattia D; Cincotti F; Babiloni F; Marciani MG; Bianchi L
    J Neurosci Methods; 2012 Jan; 203(2):361-8. PubMed ID: 22027493
    [TBL] [Abstract][Full Text] [Related]  

  • 56. P300-based BCI mouse with genetically-optimized analogue control.
    Citi L; Poli R; Cinel C; Sepulveda F
    IEEE Trans Neural Syst Rehabil Eng; 2008 Feb; 16(1):51-61. PubMed ID: 18303806
    [TBL] [Abstract][Full Text] [Related]  

  • 57. A regularized discriminative framework for EEG analysis with application to brain-computer interface.
    Tomioka R; Müller KR
    Neuroimage; 2010 Jan; 49(1):415-32. PubMed ID: 19646534
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Single-trial P300 estimation with a spatiotemporal filtering method.
    Li R; Keil A; Principe JC
    J Neurosci Methods; 2009 Mar; 177(2):488-96. PubMed ID: 19041343
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The utility metric: a novel method to assess the overall performance of discrete brain-computer interfaces.
    Dal Seno B; Matteucci M; Mainardi LT
    IEEE Trans Neural Syst Rehabil Eng; 2010 Feb; 18(1):20-8. PubMed ID: 20064766
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A comparison of three brain-computer interfaces based on event-related desynchronization, steady state visual evoked potentials, or a hybrid approach using both signals.
    Brunner C; Allison BZ; Altstätter C; Neuper C
    J Neural Eng; 2011 Apr; 8(2):025010. PubMed ID: 21436538
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.